Appendix E Modular Cabinets.doc
DOC document 101 KB Posted
- Solicitation number
- FA8604-10-R-7949
About this file
Appendix E
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Amendment 0002.pdf | ||
| Appendix C Mobile Storage System - R1.doc | DOC document | |
| FA8604-10-R-7949 00001.pdf | ||
| Revised Drawing AEG0D0-02 R1.dwg | DWG drawing | |
| A003 Level 2 Shop Drawings.doc | DOC document | |
| A007 Level 2 As-Built Drawings.doc | DOC document | |
| Contractor Information.doc | DOC document | |
| Cover PD.doc | DOC document | |
| DI DRPR 81003.pdf | ||
| A006 Requirements Certification.doc | DOC document | |
| A002 Program Schedule.doc | DOC document | |
| A004 Operation Maintenance Manuals.doc | DOC document | |
| DI MGMT 80909 T.pdf | ||
| A001Status Report.doc | DOC document | |
| Appendix F Pallet Rack.doc | DOC document | |
| A005 System Checkout Certificate.doc | DOC document | |
| DI MGMT 8022 T.pdf | ||
| Appendix B VRC.doc | DOC document | |
| DI TMSS 80527.pdf | ||
| AEG0D0-02.dwg | DWG drawing | |
| AEG0D0-01.dwg | DWG drawing | |
| FA8604-10-R-7949.pdf | ||
| Appendix A Mezzanine.doc | DOC document | |
| DI TMSS 80528 T.pdf | ||
| Appendix C Mobile Storage System.doc | DOC document |
Show all 25
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
APPENDIX E
FOR
MODULAR CABINETS
AT
EGLIN AIR FORCE BASE, FL.
AMU BUILDING 1417
CSN: AEG0D0
DATE: 15 JULY 2010
PREPARED BY:
Andrew J. Huser
PROJECT ENGINEER
403 SCMS/GUEC
THIS PAGE LEFT BLANK INTENTIONALLY
Table of Contents
11. SCOPE
2. APPLICABLE DOCUMENTS
3. REQUIREMENTS
3.1. System definition
3.2. Characteristics
3.2.1. Cabinet dimensions
3.2.1.1. MODULAR CABINETS
3.2.2. CABINET LOCK
3.2.3. Pallet base
3.2.4. Base enclosure
3.2.5. Drawers
3.2.5.1. Drawer dimensions
3.2.5.2. Drawer load capacity
3.2.5.3. Drawer Push-pull forces
3.2.5.4. Drawer divider strips
3.2.5.5. Partitions
3.2.5.6. Crosswise dividers
3.2.5.7. Drawer CONFIGURATION
3.2.5.8. Drawer pull/label-holding system
3.2.5.9. Drawer stops
3.2.5.10. Carriages and brackets
3.2.6. Shelves
3.2.7. Assembly
3.2.7.1. Alignment
3.2.7.1.1. Storage unit vertical alignment
3.2.8. Laminated Hardwood countertop
4. QUALITY ASSURANCE PROVISIONS
4.1. Inspections
4.2. Test
4.3. Certifications
!Undefined Bookmark, AUTONUMLGL SCOPE
This appendix establishes the minimum performance, design, fabrication, installation, and test requirements for a Modular Cabinet System for the 33rd Fighter Wing, in AMU Building 1417 at Eglin Air Force Base, FL. The work shall be completed in accordance with this appendix, the Cover Purchase Description (PD), and Air Force (AF) drawings AEG0D0-01 and AEG0D0-02. This appendix covers all equipment, materials, and labor necessary to complete installation of the system.
autonumlgl APPLICABLE DOCUMENTS
Applicable documents shall be in accordance with Section 2 of the Cover PD.
autonumlgl REQUIREMENTS autonumlgl System definition
The modular cabinet system shall consist of storage units, defined as a unitary set of drawers and the housing or cabinet used to support the drawers. The modular cabinet Type “G” and ”J” will be used as the base for the counter assemblies. These modular cabinet system will be accessed manually to store and retrieve small items and will consist of shelves. Type G shall be equipped with lockable doors. Units Type K and K1 shall be as shown of AF Drawing AEG0D0-02 and will be used as mobile tool boxes. The units shall be equipped with casters and drawers (Type K) and a combination of drawers and door/shelf on Type K1. Individual drawers shall be compartmentalized to provide separation between different parts. The modular cabinet system shall be located as shown on AF Drawing AEG0D0-01. The system shall be modular in construction for easy dismantling and re-assembly.
autonumlgl Characteristics autonumlgl Cabinet dimensions
3.2.1.1. MODULAR CABINETS
The modular cabinet system shall consist of storage units. The modular cabinet shall meet the following requirements + 1 inches.
| Configuration |
| Width |
| Height |
| Depth |
| “G” |
| 45” |
| 44 |
| 28.5” |
| “J |
| 45” |
| 33” |
| 28.5” |
| “K” |
| 30” |
| 37” |
| 28.5” |
| “K1” |
| 30” |
| 37” |
| 28.5” |
The cabinets shall have an outside height (which excludes the height of the pallet base) + 2 inch and also height of casters.
autonumlgl CABINET LOCK
Each cabinet of the modular cabinet system shall have a keyed lock. The lock shall prevent unauthorized entry into a cabinet drawer. The modular storage cabinet system shall have a minimum of five keys. All locks shall be keyed alike.
autonumlgl Pallet base
Each drawer cabinet shall be provided with a built-in pallet base. The pallet base shall be an integral part of the cabinet and shall have the appropriate fork guides to interface with a forklift truck or pallet jack. The pallet base shall have a height of 2½ inches + 1½ inch.
autonumlgl Base enclosure
Each cabinet shall have removable base enclosure plates to cover the front and rear of the pallet base.
autonumlgl Drawers
3.2.5.1. Drawer dimensions
The inside drawer dimensions shall be 25 inches + 1 inch depth and 20 inches +/- 1 inch width for Type K1 and and 25 inches + 1 inch width for Type K. The height of the sides and back wall of the drawer shall not be less than 48 percent of the drawer front height.
3.2.5.2. Drawer load capacity
Each drawer shall have a minimum capacity of 400 pounds. When fully loaded with 400 pounds, all drawers shall be capable of being opened and closed without jamming or twisting of the carriage. When fully loaded, an open drawer shall not exhibit deflection greater than 5/8-inch from its closed position, when measured from the floor to the middle of the front of the drawer.
3.2.5.3. Drawer Push-pull forces
The forces required to move a drawer, loaded to the maximum capacity of 400 pounds per drawer, shall not exceed 25 pounds to start outward, 45 pounds to start inward, and 40 pounds to continue moving.
3.2.5.4. Drawer divider strips
Divider strips shall be provided around the four inside walls of each drawer. The divider strips shall be factory installed, and an integral part of the drawer. The divider strips shall provide for spacing of partitions and crosswise dividers in a range of 1/2 inch to one inch intervals.
3.2.5.5. Partitions
Partitions shall be defined as drawer dividers which run from front-to-back of each drawer. All partitions shall be made of steel. Partitions shall have slot spacing to match the drawer divider strips, for placement of crosswise dividers. Each partition shall be anchored, with a minimum of two bolts and nuts or two self-tapping metal screws, to the bottom of the drawer, to keep the partition flush with the bottom of the drawer. The height of the partitions and crosswise dividers shall be no less than 75% of the height of the drawer body. All partitions shall be installed across the depth of each drawer.
3.2.5.6. Crosswise dividers
Crosswise dividers shall be defined as dividers placed between adjacent partitions or between a drawer divider strip and a partition. All crosswise dividers shall be made of steel or aluminum. Crosswise dividers shall be easily removable and interchangeable with other crosswise dividers of the same size. All crosswise dividers shall be installed across the width of each compartment.
3.2.5.7. Drawer CONFIGURATION
The quantity of each drawer height type and the drawer configuration shall be as indicated on Air Force (AF) Drawing AEG0D0-02. Each drawer shall be compartmentalized such that the assigned number of compartments are provided as indicated on Air Force (AF) Drawing AEG0D0-02.
3.2.5.8. Drawer pull/label-holding system
Each drawer front shall have an aluminum drawer pull/label-holding system. The drawer pull/label-holding system shall be approximately 75% the width of the drawer , and shall be designed to accept a label at least one inch high. The label-holding system shall have a clear plastic shield covering a paper label, with plastic or aluminum end caps that provide an enclosed label system. The contractor shall provide two spare label end caps per cabinet. There shall be no sharp protrusions on any part of the drawer pull/label-holding system.
3.2.5.9. Drawer stops
Each drawer shall be equipped with drawer stops to prevent over-travel of the drawer when fully extended. These safety stops shall prevent the drawer from being removed, unless released by the operator.
3.2.5.10. Carriages and brackets
The cabinets shall include carriages (defined as rolling intermediate members which permit 100 percent extension of the drawer interior) and minimum 10 gauge steel brackets or side channels (defined as those members fixed to the sides of the cabinets). Carriages shall operate on precision ball and/or roller bearings. All carriages and brackets shall be the same for all drawers and completely interchangeable to preclude any possibility of an unsafe mix-up of lightweight brackets and carriages with heavily loaded drawers.
3.2.6. Shelves
Type G and J shall be equipped with shelves as shown on AF Drawing AEG0D0-02. Type G shall have three shelves (one bottom and two imtermediate shelves). Type J shall have two shelves (one bottom shelf and one intermediate shelf). Each shelf shall have a load capacity of 400 pounds. The intermediate shelves shall have an adjustable height.
3.2.7. Assembly
The Contractor shall assemble, on site, all cabinets including: leveling cabinets, installing base enclosures, installing drawers in cabinets, and installing compartmentalization (partitions and crosswise dividers).
3.2.7.1. Alignment
After assembly, the storage units shall be capable of maintaining the same position in all loaded conditions. Alignment of each row of storage units shall be in two directions: down the row of storage units, maintaining the proper aisle width between adjacent rows of storage units; and vertically for each drawer/shelf cabinet face.
3.2.7.1.1. Storage unit vertical alignment
Each storage unit face shall be plumb to within 1/8-inch from the floor to the top of the unit.
3.2.8. Laminated Hardwood countertop
Each unit type shall have a 1-1/2 inch high maple work surface top as shown on AF Drawing AEG0D0-02. Type G and J shall be 96 inches long. Type K shall be 30 inches long. Type K1 shall be 45 inches long. Width for Type G, K, and K1 shall be nominal 30 inches. Type J units shall be nominal 36 inches wide to provide a six inch overhang in front of the units.
autonumlgl QUALITY ASSURANCE PROVISIONS autonumlgl Inspections
The system shall be inspected to verify that it meets all the requirements of sections 1, 2, and 3 of this appendix and the Cover PD. These inspections shall be completed as part of the system checkout test and again as a part of the quality conformance test.
autonumlgl Test
The following tests shall be performed on the system as part of the system checkout test and again as a part of the quality conformance test.
| No. |
| Paragraph |
| Description |
| autonum |
| 3.1. |
| A minimum of five cabinet drawers picked at random shall be loaded with 400 pounds. While the drawer is closed, the height to the top of the drawer from the floor shall be measured and recorded. The loaded drawer shall be open and left for a minimum of four continuous hours. The height of the top of the drawer front shall be recorded while the drawer is fully open. If an open drawer sags more than 5/8-inch when compared to its closed position, the system shall fail the test. |
| autonum |
| 3.1. |
| A minimum of five cabinet drawers picked at random shall be loaded with 400 pounds. This test may be conducted in conjunction with test number one. The amount of force to pull and push the loaded drawer shall be measured with a digital force gauge. If the drawer requires more than 25 pounds to start outwards the system shall fail the test. If the drawer requires more than 45 pounds to start inwards or more than 40 pounds to continue moving inwards the system shall fail the test. |
| autonum |
| Error! Reference source not found. |
| Ensure that all drawer interior compartments extend 100 percent out of the housing exposing all contents to reach and visibility. If the drawers do not allow for 100 percent extension, the system shall fail the test. |
autonumlgl Certifications
The Contractor shall provide certification that the following requirements have been met. All certifications shall be provided in accordance with the Contract Data Requirements List.
| No. |
| Paragraph |
| Certifications |
| 1 |
| 3.2.4.2. |
| Each drawer and shelf shall have a minimum capacity of 400 pounds. |
MODULAR DRAWER STORAGE CABINET
Offeror:
| Solicitation Number: |
| FA8604- |
-R-
| Project Title: |
| Receiving, Storage and Distribution System (DS/DS) |
| Base: |
| Eglin AFB, FL. |
| CSN: |
| AEG0D0 |
Appendix E, Modular Drawer Storage Cabinet , 15 JULY 2010
This questionnaire shall be completed by the Offeror. All entries to this questionnaire shall be typed. The questionnaire will be used to determine the Offeror's understanding of the requirements and acceptability of the proposed equipment. Please attach product literature/cut sheets for all equipment detailed in this questionnaire and attach any exceptions to the Purchase Description Appendix or recommendations/design alternatives as detailed below.
| Paragraph |
| Characteristics |
| 3.1. |
| Number of Modular Drawer Storage Cabinets provided: __________________________________________________ |
Modular Drawer Cabinet Manufacturer: ______________
Model Number: ____________________________________
3.2.1.1.
Type “G” Dimensions:
Width: _________ inches
Depth: _________ inches
Height: _________ inches
Type “J” Dimensions:
Type “K” Dimensions:
Type “K1” Dimensions:
3.2.2.
Will locks be provided:
| 3.2.4. |
| How many shelves will the Type “G” and “J” units have? |
Is a two-way pallet base provided on Types “G”,”J”, “K” and “K1”?
Height of pallet base: _______ inches
3.2.5.1.
3.2.5.2.
3.2.5.5.
Is the height of the sides and back wall of the drawer greater than 48 percent of the drawer front height?
What is the drawer minimum capacity: ____________
Are metal partitions and crosswise dividers provided?
| 3.2.5.8. |
| Does each drawer front have an aluminum drawer pull/label holding system? |
| 3.2.5.9. |
| Is each drawer equipped with drawer stops to prevent over-travel of the drawer? |
Is each drawer equipped with drawer stops to prevent over-travel of the drawer?
| Error! Reference source not found. |
| Do drawer interior compartments extend 100 percent out of the housing, to expose all contents? |
Do the drawer carriages operate on precision ball and or roller bearings?
EXCEPTIONS/RECOMMENDATIONS/DESIGN ALTERNATIVES
Attach any exceptions taken to the Purchase Description Appendix. Appendix. Please outline those concerns in detail. Your exceptions will be reviewed to determine acceptability.
Are exceptions taken?
Number of pages attached: ____________________________________
Attach any recommendations or design alternatives you feel may enhance operation, maintainability, or reduce system cost. Your recommendations and design alternatives will be reviewed to determine acceptability.
Are recommendations/design alternatives attached?
Number of pages attached: ____________________________________
We have read the requirements of the Purchase Description Appendix and will comply with all paragraphs as written, with exceptions taken only to those items indicated on the attached exception sheet.
Offeror's Signature Date
TYPED NAME:
COMPANY NAME:
ADDRESS:
PHONE:
FAX:
_1182167485
_1182169810
_1318250310
_1182169794
_1182087843
File details come from the government source that posted it. Updated .