COMPUTER GENERATED, (PRO/ENGINEER, AFPTEF)ENGINEERING DRAWING LAYOUT CFORM

JUN 75 1654AF

B

A

C

D

B

A

C

D

PARTS LISTQUANTITY REQUIRED PER DASH NO.

14.0�$�

4.034.0

118.4

123.9

131.0

116.0

125.1

153.0

R4.0

7X R1.0

45.0

19.2

18.6

5.9

10.0

( )37.0

8.00

11.8

15.40

19.40

2X R1.50

2X 10.0

2X 8.0�$�

11.6

2X 3.0

( )5.5

( )29.1 ( )22.0

1OF1SHEET1:1SCALE

20171450

DRAWING NO.AF. CODE IDENT NO.

0B275

SIZE

C

BASE EXTRUSION

TITLE

U.S. AIR FORCE

R. L. MILLER

AIR FORCE RELEASE 19-02-13

M. R. HARFF

AIR FORCE AUTHENTICATION

B. C. BAVER

ENG

J. A. SULLIVAN

CHK

B. C. BAVER

DR

METRIC

CURRENT

CODE IDENT NO.

REVISIONS

APPROVEDDATEDESCRIPTIONLTR

FIND NO.ZONEUNIT WTMATERIAL/SPECIFICATIONIDENTIFYING NO.CODE IDENTNOMENCLATURESYM

-01

APPLICATION

USED ONNEXT ASSEMBLY

ALUMINUM

6063-T6 PER

ASTM B221M

4.85 Kg/M

MATERIALS:

.X�#�

.XX�#�

ANGLESDECIMALSFRACTIONS

UNLESS OTHERWISE SPECIFIED

DIMENSIONS ARE IN MILLIMETERS - TOLERANCES ON:

NOTES:

1. INTERPRET DRAWING IAW ASME Y14.100M-2000 AND ASME Y14.5M-1994.

2. ALL CONVERSIONS FROM METRIC TO ENGLISH AND/OR

ENGLISH TO METRIC UNITS SHALL BE IAW ANSI/ASTM SI 10.

3. ALL RADII 3.0mm UNLESS STATED OTHERWISE.

EXTRUSION TOLERANCES IAW ANSI/AA H35.2(M) UNLESS STATED OTHERWISE.

ALL WALL THICKNESSES 3.0mm UNLESS NOTED OTHERWISE.

DIMENSION APPLIES AT THE INTERSECTION OF SHARP CORNER CREATED BY

EXTENSION LINES FROM ADAJACENT SURFACES. SEE EXAMPLE GRAPHIC ON

THIS DRAWING.

SEE DETAIL A

DETAIL A

SCALE 1:1

DISTRIBUTION STATEMENT D : DISTRIBUTION AUTHORIZED TO

THE DEPARTMENT OF DEFENSE AND U.S. DOD CONTRACTORS

ONLY; ADMINISTRATIVE/OPERATIONAL USE; 18-MAY-2011. OTHER

REQUESTS SHALL BE REFERRED TO THE AIR FORCE PACKAGING

TECHNOLOGY & ENGINEERING FACILITY, DAYTON, OH 45433.

DESTRUCTION NOTICE : DESTROY BY ANY METHOD THAT WILL

PREVENT DISCLOSURE OF CONTENTS OR RECONSTRUCTION OF

THE DOCUMENT

EXTENSION LINE

DIMENSIONING

DIM1 DIM2