Studio Light

FB230052380010

19 October 2015

The NMUSAF requires 160 studio lights that match existing installed light fixtures and compatible with all Electronic Theatre Control, Inc. operational consoles and interfaces.

A: Brand name or equal-

Physical, Functional and Performance Characteristics: Electronic Theatre Control D60 or equal-

1. Breakdown of Tungsten/Daylight shall be-80 units Tungsten and 80 units Daylight wash fixtures

2. or comparable.(Tungsten acceptable Color Temperature Range to be 2700-3800 and Daylight Color Temperature Range 4000-6400 +/- on both units to=10%.

3. Wash Fixture shall utilize Luxeon Rebel LED Emitter's. LED emitters should be rated for nominal 50,000 LED life to 70% intensity.

4. The fixture shall be UL 1573 listed for stage and studio use.

5. Measured brightness of the StudioTungsten array shall be greater than 5700 field lumens.

6. Measured brightness of the Studio Daylight array shall be greater than 7500 field lumens.

7. Wash light needs to have (RDM) Random Device Management and be compatible with existing Gateway Digital Multiplexer (DMX) distribution functions in existing Electronic Theatre Controls-Ion control console ( upgrade shall be installed/provided @ no EXTRA CHARGE for substituted devises and the fixture comply with the United States Institute of Theatre Technology (USITT) DMX-512A standard.

8. All units should be complete with: Wire rope safety, 2P&G(Male) pin connector(Bates Style Only) to Powercon(Blue) input lead, and Pipe style C- clamp.

9. Must match existing installed light fixtures and compatible with all Electronic Theatre Control, Inc. (ETC), Electronic Theatre Control Ion Operational Console and ETC, DMX Gateway interfaces.