This Request for Information (RFI) provides technical specification details for a valving machine with specific dimensional and power requirements. The document outlines three key parameters: (1) cylinder diameter ranging from 3" to 16" (current requirement is 3" to 14"), (2) cylinder height specifications from 6" to 56", and (3) power supply options including both 3-phase and single-phase configurations. The document appears to be directly related to the Air Force Sustainment Center's Solicitation FA857125Q0064, which is a small business set-aside for a commercial valving machine procurement.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Request for information:
1. Cylinder diameter Ø, smallest and largest?
Our current requirement is 3” up to 14” but we’ve specified 3” up to 16” for possible larger requirements coming.
2. Cylinder height, shortest and tallest?
6” to 56”
3. Power supply on 3 phase?
We have 3-phase or single phase available