This document contains questions and answers regarding Solicitation Number FA857124Q0024 for a scrubber system. The solicitation is seeking a horizontal conveyorized surface scrubber used in printed circuit board manufacturing to be installed indoors. The scrubber must be a standalone piece of equipment connected to power and water. It will scrub 16"x18"x0.013-0.225" copper-covered fiberglass core panels passing through on a conveyor. The space for the scrubber is constrained to 12'x12'. The questions and answers provide clarification but do not specify additional requirements regarding the type, quantity, or pricing of the scrubber system sought.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Scrubber System
FA8571-24-Q-0024
5 December 2023
Questions and Answers
We are looking for a horizontal conveyorized surface (brush) scrubber used in printed circuit board (PCB) manufacturing. It should be a stand-alone piece of equipment with power and a water connection.
Indoors/ outdoors ? It is process equipment that will be INDOORS.
* Configuration of vessel ? Vertical or horizontal ? Flat bottom ? dome or flat top ? n/a. It is a piece of equipment that a 16”x18”x (0.013-0.225)” copper-covered fiberglass core panel will go in one side, be scrubbed, and come out on the other side. We stated that our space constraint is 12’x12’.
* Vessel diameter n/a – question doesn’t relate to our need. Looks like an air scrubber question to me, because I know nothing about the topic.
* Vessel shell height n/a – question doesn’t relate to our need.
* Design Pressure: n/a – question doesn’t relate to our need.
* Design temperature: n/a – question doesn’t relate to our need.
* Contents at gas/air inlet: n/a – question doesn’t relate to our need.
* Contents at liquid inlet (if any liquid is to be added): n/a – question as they ask doesn’t relate to our need. We do state it should have water washing at 10 bar.
* List of all fittings including couplings, flanged nozzles, manways, duct flange for air
Inlet, duct flange for air outlet. n/a – question doesn’t relate to our need.
* Internals like size/ configuration of liquid header spool, support ledges needed for
Packing media/ demister/mist eliminator/ liquid distribution tray if needed, Support beams needed, liquid distributor tray ??, n/a – question doesn’t relate to our need.
* Operating Weight of packing media ? mist eliminator/demister? n/a – question doesn’t relate to our need.
* IF any additional items such as ladders, platforms, insulation, etc. are needed