QA807.pdf

PDF 83 KB Posted

Attached to
Overhaul/Repair of UH-1N Transmission Assembly
Solicitation number
FA8524-19-Q-0001
Issued by

About this file

Quality Assurance Form

View the file

Other files

File Type Posted
PWS_(FINAL)V2.pdf PDF
GFP_FORM_PDF_v2.pdf PDF
CAVAF_Reporting_Instructions.pdf PDF
SPI_000564868.pdf PDF
DD1653.pdf PDF
DD_2875_SYSTEM_AUTHORIZATION.pdf PDF
PWS_v3_(003).pdf PDF
AFMC158.pdf PDF
UH-1N_Transmission_Repair_Pre-Qual_V3_SIGNED.pdf PDF
DD1423.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

RECOMMENDED QUALITY ASSURANCE PROVISIONS

AND SPECIAL INSPECTION REQUIREMENTS

1. PR / MIPR NUMBER

2. NATIONAL STOCK NUMBER

1615010616615GA

3. POINT OF INSPECTION

SOURCE DESTINATION

X

SEE DFARS 246.402

4. POINT OF ACCEPTANCE

SOURCE DESTINATION

X

5. ITEM MANAGER / PHONE

Bryant, Juan L / 478-222-0832

6. EQUIPMENT SPEC / PHONE

Brown, James A / 478-327-6961

7. CONTRACT QUALITY REQUIREMENTS/SPECIAL INSPECTION REQUIREMENTS

CERTIFICATE OF CONFORMANCE

FAR 52.246-15

CONTRACT RESPONSIBILITY

FOR INSPECTION

FAR 52.246-1

STANDARD INSPECTION

FAR 52.246-2,-3,-4,-5 OR -6

AS APPLICABLE TO CONTRACT

HIGHER LEVEL CONTRACT QUALITY REQUIREMENTS

COMMERCIAL ITEM INSPECTION

FAR 52.212-4

X OTHER (Describe in Block 8)

8. REMARKS

Lamb, Steven HNAME: 25 APR 2018DATE:

This is a Critical Safety Item (CSI), Higher level contract quality is required, minimum ISO 9001:2008, AS9100 or AS9110.

8a. OZONE DEPLETING SUBSTANCES (ODS)

X STATEMENT

"I HAVE REVIEWED THE REQUIREMENT, INCLUDING AVAILABLE TECHNICAL DOCUMENTATION, AND BELIEVE THAT IT DOES NOT REQUIRE THE CONTRACTOR USE CLASS I OZONE DEPLETING SUBSTANCES (ODS) IDENTIFIED IN AIR FORCE POLICY, NOR IS IT WRITTEN SO THAT IT CAN

ONLY BE MET BY THE USE OF A CLASS I ODS."

WAIVER (SEE AF FARS 5323)

NOTE: Quality provisions as annotated hereon will not be downgraded without Technical Authority coordination. The Technical Authority must be notified if award selection is made to a new source using Acquisition Method Code (AMC) 3, 4, or 5.

9. QUALITY PRE-AWARD SURVEY

X YES X NEW SOURCE

PREVIOUS SOURCENO

X AFMC PARTICIPATION

RECOMMENDED

10. CODES

A. I&A

B. CQR

I

11. SIGNATURE OF TECHNICAL AUTHORITY

Lamb, Steven H

ORGANIZATION / SYMBOL

AFLCMC / WIUEE

PHONE

478-327-3329 / 497-3329

DATE

25 APR 2018

Page 1 of 1AFMC FORM 807, 20060111, V1 Version 2Generated by PRPS using Jasper Reports on 17 Oct 2018

File details come from the government source that posted it.