QAIRQMT_REPORT.pdf

PDF 84 KB Posted

Attached to
URGENT 100% Small Business Set Aside for KC-135 Orifice Support Tube Assembly
Solicitation number
FA8203-16-R-1719
Issued by

About this file

Quality Assurance Provisions

View the file

Other files

File Type Posted
CDRL.pdf PDF
FA_REPORT.pdf PDF
ITMDESC_REPORT.pdf PDF
PKGRQMT_REPORT.pdf PDF
Attachement_A_(CSI).pdf PDF
TRNSPDATA_REPORT.pdf PDF
EDL_REPORT.pdf PDF
Solicitation.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

RECOMMENDED QUALITY ASSURANCE PROVISIONS

AND SPECIAL INSPECTION REQUIREMENTS

1. PR / MIPR NUMBER

2. NATIONAL STOCK NUMBER

1620011500027

3. POINT OF INSPECTION

SOURCE DESTINATION

X

SEE DFARS 246.402

4. POINT OF ACCEPTANCE

SOURCE DESTINATION

X

5. ITEM MANAGER / PHONE

Joseph, Robert L / 801-775-4103

6. EQUIPMENT SPEC / PHONE

7. CONTRACT QUALITY REQUIREMENTS/SPECIAL INSPECTION REQUIREMENTS

CERTIFICATE OF CONFORMANCE

FAR 52.246-15

CONTRACT RESPONSIBILITY

FOR INSPECTION

FAR 52.246-1

STANDARD INSPECTION

FAR 52.246-2,-3,-4,-5 OR -6

AS APPLICABLE TO CONTRACT

X HIGHER LEVEL CONTRACT QUALITY REQUIREMENTS

ISO 9001:2000

COMMERCIAL ITEM INSPECTION

FAR 52.212-4

OTHER (Describe in Block 8)

8. REMARKS

Naylor, Jeffrey TNAME: 26 JAN 2015DATE:

This component requires inspection and acceptance at source and meets the following criteria in accordance with AFMCI 23-102:

Quality Assurance Letter of Instruction (QALI):

- Significant Technical Requirements to ensure configuration baseline

- Critical production features to ensure safety of flights aspects of this component

- Contract is awarded to manufacturer of this item

Defense Contract Management Agency (DCMA) will provide the necessary technical and administrative oversight to ensure the requirements of section 8 and the Technical data Package (TDP) provided by the contract are complied with. See attached 'Landing Gear QALI letter' for CSI and CAI inspection requirements.

8a. OZONE DEPLETING SUBSTANCES (ODS)

X STATEMENT

"I HAVE REVIEWED THE REQUIREMENT, INCLUDING AVAILABLE TECHNICAL DOCUMENTATION, AND BELIEVE THAT IT DOES NOT REQUIRE THE CONTRACTOR USE CLASS I OZONE DEPLETING SUBSTANCES (ODS) IDENTIFIED IN AIR FORCE POLICY, NOR IS IT WRITTEN SO THAT IT CAN

ONLY BE MET BY THE USE OF A CLASS I ODS."

WAIVER (SEE AF FARS 5323)

NOTE: Quality provisions as annotated hereon will not be downgraded without Technical Authority coordination. The Technical Authority must be notified if award selection is made to a new source using Acquisition Method Code (AMC) 3, 4, or 5.

9. QUALITY PRE-AWARD SURVEY

YES NEW SOURCE

PREVIOUS SOURCEX NO

AFMC PARTICIPATION

RECOMMENDED

10. CODES

A. I&A

B. CQR

G

11. SIGNATURE OF TECHNICAL AUTHORITY

Naylor, Jeffrey T

ORGANIZATION / SYMBOL

417 SCMS / GUEA

PHONE

801-777-8716 / 777-8716

DATE

26 JAN 2015

Page 1 of 1AFMC FORM 807, 20060111, V1 Version 1Generated by PRPS using Jasper Reports on 27 Jul 2016

File details come from the government source that posted it. Updated .