The document is a DD Form 1354 Checklist, a comprehensive template for documenting detailed property and facility information. The checklist contains multiple sections capturing extensive technical details about building characteristics, including:

Section 1 covers building dimensions and construction materials, requiring precise measurements of building components like length, width, ceiling heights, and specific construction material types for structural elements, walls, floors, and foundations. Subsequent sections inventory utility connections, installed equipment, building systems (fire protection, security, heating, air conditioning, electrical), and specialized facilities across categories like shops, chapels, theaters, billeting buildings, and MWR facilities. The final section lists recyclable materials that can be recovered and remanufactured, including metals, concrete, wood products, plastics, and mechanical/electrical equipment, with instructions to report recyclable products by weight to the Contracting Officer.

View the file

Other files

File Type Posted
Solicitation Amendment FA813725R00350008 SF 30.pdf PDF
Solicitation Amendment FA813725R00350009 SF 30.pdf PDF
190068_GOVT RESPONSE TO RFI 25A AND REDATED RESPONSE COR.pdf PDF
Solicitation Amendment FA813725R00350006 SF 30.pdf PDF
WWYK190068_RFI_23-24-25 SEP24.pdf PDF
Capsol Mini LED Text Displays - Capsol.pdf PDF
RFI 26 Fixture with Joist.pdf PDF
RFI - Light Fixtures in Joist Ceiling RFI 26 COR.pdf PDF
190068_Attch04_Revised_Design_Analysis.pdf PDF
190068_Attch02_Revised_Submittal_Register.pdf PDF
Solicitation Amendment FA813725R00350004 SF 30.pdf PDF
Solicitation Amendment FA813725R00350002 SF 30.pdf PDF
190068_IFC_Design Analysis_Final.pdf PDF
190068_DD100_Appendix A.pdf PDF
000111_F1.pdf PDF
UFGS 28 31 76.pdf_safe.pdf PDF
fire prot-01.pdf PDF
Solicitation Amendment FA813725R00350001 SF 30.pdf PDF
EMS General Awareness Training for Contractors Aug 2018 PDF.pdf PDF
00 70 00.pdf PDF
tinkerafb_INRMP.pdf PDF
dafman91-203.pdf PDF
ufc_3_260_04_2018.pdf PDF
afi91-202_afmcsup.pdf PDF
ufc_3_601_02_2021.pdf PDF
dafi91-202.pdf PDF
tinkerafbi21-100.pdf PDF
tinkerafb_INRMP_App E.pdf PDF
017800_Attch1_DD1354.pdf PDF
WWYK190068 2nd SiteVisit Signin 23JUN25.pdf PDF
01 42 00.pdf PDF
01 50 00.pdf PDF
Tinker General Requirements Specifications_Nov 2022_Change Log.pdf PDF
01 33 16.00 10.pdf PDF
UMRL.pdf PDF
ufc_3_260_01_2019_c1.pdf PDF
ufc_3_535_01_2017_c4.pdf PDF
tinkerafb_INRMP_App G.pdf PDF
afman48-148.pdf PDF
TAFB_SOP_outages_v2.pdf PDF
dodio-2000.16v1_afi10-245-o.pdf PDF
VEAL Template.pdf PDF
007200_Attch9_EMS Awareness Training.pdf PDF
007100_Attch1_Airfield Construction Waiver.pdf PDF
dafi13-213_tinkerafbsup.pdf PDF
00 72 00.pdf PDF
00 71 00.pdf PDF
190068_ATT10_Submittal_Register.pdf PDF
190068_ATT9_SOW.pdf PDF
EAL List - 190068.xlsx XLSX spreadsheet
Show 40 more

50 files listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DD Form 1354 Checklist

Facility Number Building Name

Number of Floors

Gross SF Net SF

1. Building Dimensions and Construction Material

Building Outside Dimensions Length (LF) Width (LF)

Main Building Wings Offsets Basement Attic Porches, Covered Roof Foundation

Other Building Data Feet

Ceiling Height Main Bldg Ceiling Height Basement Door Height Door With

Code

Fire Rating Code

Construction Materials Type

Principal Struct Material Secondary Struct Material Exterior Wall Material Interior Wall Material Floor Surface Material Sub-Floor Material

Construction Materials (Pavements) Type

Surface Course Materials Base Course Materials

2. Utility Connection, Information, and Fuel Data:

Utility Connections

Number of Pipes

Diameter of Each Pipe

Capacity of All Inlet Pipes

Available or Connected?

(Yes / No)

Water Gas Sewer Pipe Storm Sewer Pipe Steam Condensate Comm.

System Energy Type Source Location

Fuel Description

Air Circulation

Heating Air Conditioning Hot Water Steam Electric

Electric Phase/ Voltage Wire Size

Connected Load – Amps

Connected Load - KVA

3. Installed Real Property

a. Building Systems:

(1) Fire Protection System:

Category

Nomenclature

Unit of Measure

Qty

Cost

Serial Number /

Closed Head Auto Sprinklers

SF

HD

Open Head Deluge System

SF

HD

Auto Fire Detection System

SF

EA

Manual Fire Alarm System EA CO2 Fire System EA Foam Fire System EA Other Fire System EA Halon 1301 Fire System EA

(2) Security System:

Security Alarm System EA

(3) Heating System:

Heating Plant 750/3500 MB MB Heating Plant Over 3500 MB MB

Storage Tank for Heating Or Generator Fuel

GA

TYPE NA NA

FUEL NA NA

(4) Air Conditioning System:

A/C Window Units

TN

SF

A/C Plant Less than 5 TN

TN

SF

A/C Plant 5 to 25 TN TN A/C Plant 25 to 100 TN TN A/C Plant Over 100 TN TN

(5) Electrical System:

Electric Emergency Power Generator KW

Storage Tank for Heating or Generator Fuel

GA

b. Real Property Installed Equipment:

Item

Measure Qty

Model

Evaporative Coolers CFM Hot Water Heater GA Exhaust Fan CFM Wash Basin EA Water Closet EA Urinal EA Utility Sink EA Refrigerated Drinking Fountain EA Heating Plant under 750 MB MB Forced Air Heating BTU Other Heating BTU Dehumidifiers GPM

Elevators Lbs

PN

Theater-Type Seats Secured To Floor EA Other

c. Related Facilities Added:

Prim Distr Line OH LF Transformers KVA Power Poles LF Sec Distr Line OH LF Prim Distr Line UG LF Sec Distr Line UG LF

Exterior Street Lighting or Parking Area Lights EA

Gas Mains LF Sewage Septic Tank KG Sanitary Sewer LF Water Distr Mains LF Fire Hydrants EA Curbs & Gutters LF Driveway SY

Road

SY

LF

Vehicle Parking SY Storm Drain LF Fence, Security LF Fence, Interior LF Sidewalk SY

Utility Vault (4 or more transformers) SF

Tel Duct Facility LF Tel Pole Facility LF

d. Specialized Facilities/RPIE Added:

(1) Shops:

Amount

Serial Number

Air Compressors HP Hoists, Cranes (fixed) TN Hydraulic Lifts TN Emergency Shower EA Fixed Spray Paint Booth EA Load and Unload Platform SF Industrial Waste Main LF Compressed Air Dist LF

(2) Chapel:

Pews EA Altars EA Lecterns EA Pulpit EA

(3) Theater:

Theater Seats Secured to Floor EA

Fire Screens EA

(4) Billeting Buildings:

Built-in Household

Dishwasher EA

Garbage Disposals EA

Built-in Domestic Ranges and Ovens EA

Range Canopy w/Exhaust Fan EA

Water Softener, Household Type EA

(5) MWR Buildings:

Dishwashers, Built-in EA

Walk-in Refrigerators Built-in EA

Garbage Disposal Unit EA

Range Canopy w/ Exhaust Canopy System EA

PA System, Built-in EA Vault, Built-in EA Stage and Auditorium SF

Playground Equipment Permanently Affixed EA

Bowling Alley Lanes, LA

Approaches, Ball Returns Load & Unload Platforms SF

(6) Post Office:

Post office lock boxes EA

(7) List any other items installed, but not listed above. Please indicate size, square footage, amount, number of units, etc. as applicable.

4. Removed Real Property

a. Building Systems:

(1) Fire Protection System:

Closed Head Auto Sprinklers

SF

HD

Open Head Deluge System

SF

HD

Auto Fire Detection System

SF

EA

Manual Fire Alarm System EA CO2 Fire System EA Foam Fire System EA Other Fire System EA Halon 1301 Fire System EA

(2) Security System:

Security Alarm System EA

(3) Heating System:

Heating Plant 750/3500 MB MB Heating Plant Over 3500 MB MB

Storage Tank for Heating Or Generator Fuel

GA

(4) Air Conditioning System:

A/C Window Units

TN

SF

A/C Plant Less than 5 TN

TN

SF

A/C Plant 5 to 25 TN TN A/C Plant 25 to 100 TN TN A/C Plant Over 100 TN TN

(5) Electrical System:

Electric Emergency Power Generator KW

Storage Tank for Heating or Generator Fuel

GA

b. Real Property Installed Equipment:

Item

Measure Qty

Model

Evaporative Coolers CFM Hot Water Heater GA Exhaust Fan CFM Wash Basin EA Water Closet EA Urinal EA Utility Sink EA Refrigerated Drinking Fountain EA Heating Plant under 750 MB MB Forced Air Heating BTU Other Heating BTU Dehumidifiers GPM

Elevators Lbs

PN

Theater-Type Seats Secured To Floor EA Other

c. Related Facilities Removed:

Prim Distr Line OH LF Transformers KVA Power Poles LF Sec Distr Line OH LF Prim Distr Line UG LF Sec Distr Line UG LF

Exterior Street Lighting or Parking Area Lights EA

Gas Mains LF Sewage Septic Tank KG Sanitary Sewer LF Water Distr Mains LF Fire Hydrants EA Curbs & Gutters LF Driveway SY

Road

SY

LF

Vehicle Parking SY Storm Drain LF Fence, Security LF Fence, Interior LF Sidewalk SY

Utility Vault (4 or more transformers) SF

Tel Duct Facility LF Tel Pole Facility LF

d. Specialized Facilities/RPIE Removed:

(1) Shops:

Air Compressors HP Hoists, Cranes (fixed) TN Hydraulic Lifts TN Emergency Shower EA Fixed Spray Paint Booth EA Load and Unload Platform SF Industrial Waste Main LF Compressed Air Dist LF

(2) Chapel:

Pews EA Altars EA Lecterns EA Pulpit EA

(3) Theater:

Theater Seats Secured to Floor EA

Fire Screens EA

(4) Billeting Buildings:

Built-in Household

Dishwasher EA

Garbage Disposals EA

Built-in Domestic Ranges and Ovens EA

Range Canopy w/Exhaust Fan EA

Water Softener, Household Type EA

(5) MWR Buildings:

Dishwashers, Built-in EA

Walk-in Refrigerators Built-in EA

Garbage Disposal Unit EA

Range Canopy w/ Exhaust Canopy System EA

PA System, Built-in EA Vault, Built-in EA Stage and Auditorium SF

Playground Equipment Permanently Affixed EA

Bowling Alley Lanes, LA

Approaches, Ball Returns Load & Unload Platforms SF

(6) Post Office:

Post office lock boxes EA

(7) List any other items removed, but not listed above. Please indicate size, square footage, amount, number of units, etc. as applicable.

e. List products and materials that can be recovered and remanufactured into a new product. Recyclable materials include, but are not limited to, the following:

(1) Metals (ferrous and non-ferrous), including banding, metal studs, ductwork and piping.

(2) Asphaltic concrete paving

(3) Portland cement concrete

(4) Land clearing debris including trees and plant materials

(5) Native rock and granular fill

(6) Gypsum products

(7) Paper and cardboard

(8) Wood products, including structural, finish, crates and pallets

(9) Brick and masonry

(10) Plastics

(11) Copper wiring

(12) Mechanical and electrical products and equipment

These recyclable products shall be reported by weight to the Contracting Officer.

-- End of Attachment 1 -–