This is a Memorandum for Record documenting item specifications for a brand name or equivalent procurement of a Porta-King Versa-King 3-inch Wall System by the 76th Maintenance Support Group at Tinker Air Force Base.

The procurement specifies one unit with nominal dimensions of 21'6"W x 29'2"L x 17'0"H configured as a 4-wall enclosure. Perimeter walls must feature aluminum post and framing components with minimum 3-inch panel thickness, painted steel on drywall finish in white on both exterior and interior, UL Class 1 EPS core, white aluminum extrusion, and minimum R-10 thermal insulation value. The roof/ceiling assembly requires minimum 70 psf total load capacity (20 psf live load, 20 psf dead load), Corrugated Type "B" metal roof deck, 1½" rubber deck end closures and foam deck plugs, roof cap, three equidistant maintenance load beams (W12x14 minimum, 21'6" each), six support columns, wall girts, and a complete acoustical ceiling system at customizable height with 15-foot minimum clearance. The enclosure includes three fixed 4'x4' windows with clear tempered safety glass, two 3070 steel doors with 24-gauge galvanized steel, solid insulating core, and 23"x29" vision lite windows, electrical components (two 3-way light switches, eight 115V duplex outlets, ten recessed 2'x4' LED panel lights, one 125-amp single-phase 12-circuit load center), one 10'x10' roll-up door with manual chain hoist operation, and one 24"x24" wall-mounted adjustable louver. All materials, components, and assembly/installation instructions must be provided for self-installation, with customizable layout and location options for all doors, windows, louvers, and roll-up doors.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DEPARTMENT OF THE AIR FORCE

HEADQUARTERS AIR FORCE SUSTAINMENT CENTER (AFMC)

TINKER AIR FORCE BASE OKLAHOMA

24 June 2026

MEMORANDUM FOR RECORD

SUBJECT: Item Description, M26-206 Versa-King 3inch Wall System

1. The 76th Maintenance Support Group (MXSG) is requesting utilization of funds for the brand name or equivalent purchase of a Porta-King's (OEM), Versa-King Wall System (Model).

2. The requested equipment item descriptions/specifications are outlined below.

a. Item one – VERSA-KING 3" WALL SYSTEM

(1) Nominal Dimensions: 21'6"W x 29'2"L x 17'0”H / 4-Wall Enclosure

(2) Quantity: One (1)

(3) Additional components, accessories, or information about item a.

(a) Perimeter Walls

i. Aluminum post and framing components

ii. Minimum wall panel thickness: 3”

iii. Exterior Finish Material: Painted Steel on Drywall

iv. Exterior Color: White

v. Interior Finish Material: Painted Steel on Drywall

vi. Interior Color: White

vii. UL Class 1 EPS Core

viii. White Aluminum Extrusion

ix. Minimum thermal insulating value: R 10

(b) Roof/Ceiling

i. Minimum roof load capacity: 70psf total

1. Minimum roof live load capacity: 20psf

2. Minimum roof dead load capacity: 20psf

ii. Corrugated Type “B” Metal Roof Deck

iii. 1½” rubber deck end closures and foam deck plugs

iv. Roof cap

v. 3ea. maintenance load beam equidistant spans on 29’-2” perimeter wall

1. W12x14 minimum

2. Length: 21’-6” each

3. Accessible from inside of enclosure (between acoustical ceiling system and “B” metal roof deck)

vi. 6ea. Support Columns (2ea. per maintenance load beam)

vii. Wall girts

viii. Complete acoustical ceiling system at customizable height (minimum height: 15’ AFF)

(c) Windows

i. 3ea. fixed windows (height to bottom of window: 4’ AFF)

1. Nominal dimensions: 4’x 4’

2. Clear tempered safety glass

(d) Doors

i. 2ea. 3070 Steel Door

1. 24-gauge galvanized steel with solid insulating core

2. 23” x 29” Vision Lite windows

3. Clear tempered safety glass

4. Best lever lockset w/ construction core

5. Finish Color: White

6. Installs flush with wall panels

(e) Electrical

i. 2ea. 3-way light switch w/modular wiring

1. One installed at each door (4’ AFF)

ii. 8ea. 115V duplex outlet w/modular wiring

1. Installed 2’ AFF

iii. 10ea. recessed 2’x4’ flat panel LED light w/modular wiring

1. To be installed within complete acoustical ceiling system

iv. 1ea. 125 amp, single phase 12 circuit load center w/modular wiring and preinstalled breakers

v. Easy access wiring chase (max. 4’ o.c.)

(f) Overhead/Roll Up Door

i. 1ea. 10’ x 10’ steel framed opening

ii. 1 ea. 10’ x 10’ roll up door

1. Manual operation/chain hoisted

2. Mounted to interior of perimeter wall

(g) 1ea. 24” x 24” wall mounted adjustable louver (height: 1’ AFF minimum)

3. Must include all materials/components and assembly/installation instructions for self-installation.

4. Layout and locations of doors/windows/louver/roll up door must be customizable.