This is a Questions and Answers document for solicitation FA812625Q0010 (M24-006) regarding a Plasma Dust Collector system. The document outlines technical specifications and requirements including that the system will handle plasma spray powder containing heavy metals and thorium (radioactive), with potentially flammable dust/gas present. The system requires 10,000cfm capacity with water gauge measurements for suction loss, and must be designed to handle 20" w.g. in case of blockage.
Key technical specifications include a HEPA filtration system rated at 99.97% efficient at 0.3 microns, power requirements of two 480V 3-phase feeds at 30amps each, and compressed air requirements of 12-24acfm@90psi with two independent 20 CFM feeds at 100psi each. The system will be installed outside the building for air exhaust, though noise level requirements are not specified. The power configuration can alternatively be set up as a 60amp single feed split at the collector.