Appendix J - Calibratable Items
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Appendix_D_Glossary_and_Definitions.pdf | ||
| Statement_of_Work.pdf | ||
| Appendix_M_Pressue_Test_Chart.pdf | ||
| Appendix_F_Certification_Test_Plan.pdf | ||
| Appendix_E_Environmental.pdf | ||
| FA8125-19-Q-A022_Combo.pdf | ||
| Appendix_I_Unit_Under_Test.pdf | ||
| Data_Item_Description_DI_IPSC_81488.pdf | ||
| Appendix_K_RCM_and_VIB_Severity_Chart.pdf | ||
| Appendix_G_Acceptance_Test_Report.pdf | ||
| Appendix_N_CDRL_DD1423_1_A001_and_DD1423_1_A002.pdf | ||
| Appendix_C_Safety_Specification.pdf | ||
| Data_Item_Description_DI_TMSS_81723.pdf | ||
| Appendix_L_Test_Stand_Manual.pdf | ||
| Appendix_A_76_CMXG_Design_Standards_and_Guidelines.pdf |
Show all 15
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Appendix J – Calibratable Items
TAG Number Nomenclature Calibration Range
Required Accuracy*
Calibration Instrument Test to Accuracy Ratio Required
(TAR)
Suggested Calibration Instrument*
Frequency
ZT_1105 Inclinometer 0 - 90° ±1° 4:1 PRO360 Digital Protractor
6 months
PT_1001, 1201 Pressure Transducer
0 - 100 psig ± 0.50 psig 4:1 Druck DP 510 or Ruska 7250XI
6 months
PT_1202 Pressure Transducer
0 - 5 psig ± 0.10 psig 4:1 Druck DP 510 or Ruska 7250XI
6 months
PT_1203 Pressure Transducer
5 - 30 psia ± 0.50 psia 4:1 Druck DP 510 or Ruska 7250XI
6 months
PT_1105 Pressure Transducer
5 - 30 psia ± 0.50 psia 4:1 Druck DP 510 or Ruska 7250XI
6 months
PDT_1107 Pressure Transducer
0 - 5 psid ± 0.10 psid 4:1 Druck DP 510 or Ruska 7250XI
6 months
PDT_1201 Pressure Transducer
0 - 15 psid ± 0.10 psid 4:1 Druck DP 510 or Ruska 7250XI
6 months
PDT_1002, 1101 Pressure Transducer
0 - 10 psid ± 0.10 psid 4:1 Druck DP 510 or Ruska 7250XI
6 months
PDT_1202,
PDT_1202_Fast
Pressure Transducer
0 - 50 psid ± 0.10 psid 4:1 Druck DP 510 or Ruska 7250XI
6 months
LT_1104 Reservoir T-2 Level
0 - 25 inH2O @4°C
± 0.15 in H2O
4:1 Druck DP 510 or Ruska 7250XI
6 months
LT_1105 Reservoir T-3 Level
0 - 30 inH2O @4°C
± 0.25 in H2O
4:1 Druck DP 510 or Ruska 7250XI
6 months
TE_1101, 1102,
1103, R19
RTD (PT100-
385)
103.90- 125.37 (50 - 150°F)
±0.42 Ω** 2:1 8840A Hart Scientific 9105 or 9171
6 months
TE_1101, 1102,
1103, R19
Temperature Input Channel
50 - 150 °F ±1.0 ° F 2:1 Fluke 5520 6 months
FT_1101 Flow Turbine Meter
50 – 350 gpm
± 0.4 % 4:1 See Section Aligning\Calibra ting Flow Meter
12 months
FT_1102 Flow Turbine Meter
1.6 – 65 gpm
± 0.4 % 4:1 See Section Aligning\Calibra ting Flow Meter
12 months
Range
Required Accuracy*
Calibration Instrument Test to Accuracy Ratio Required
(TAR)
Suggested Calibration Instrument*
FT_1103 Flow Turbine Meter
4 – 60 gpm ± 0.9 % 4:1 See Section Aligning\Calibra ting Flow Meter
FT_1104
Flow Turbine Meter
8 – 130 gpm ±.0.9 % 4:1 See Section Aligning\Calibra ting Flow Meter
12 months
FT_1101, 1102,
1103, 1104, Flow Counter Channel
10 – 2000 Hz
± 0.15% of reading
4:1 HP 3325A,
Fluke 5520 or Fluke 5720
6 months
FT_1101_Fast Flow Counter Channel
50 – 2000 Hz
± 0.15% of reading
4:1 HP 3325A,
Fluke 5520 or Fluke 5720
6 months
DT_1100
Corrected Fluid Density @ 60 Deg F.
Density Transducer
0.75 - 0.770 sgu
± 0.002 sgu 4:1 Mettler DE 40 6 months
IT-100 Current Shunt Input Channel
0 - 25A ± 0.1 A 4:1 Fluke5520, 8840A, HP3478A
6 months
EI-1110, 1112 Voltage Indicator
0 - 10.5
VDC
± 0.1 VDC 4:1 Fluke 5720A/5520
6 months
EI-1113 Voltage Indicator
0-1 VDC ± 0.01 VDC 4:1 Fluke 5720A/5520
6 months
EI-1111 Voltage Indicator
0 - 50 mVDC
± 0.1 mVDC
4:1 Fluke 5720A/5520
6 months
EI-DC1 Voltage 0 - 300VDC ± 1.0VDC 4:1 Fluke 5720A/5725A
6 months
IY-1108 Current Source / Transmitter Simulator
4 - 20 mADC
± 0.05 mADC
4:1 Fluke5520, 8840A, HP3478A
6 months
WT_100 Power Analyzer 6 months
Voltage 0 - 230
VRMS L-N
(40 - 450Hz)
± 1.0VRMS
4:1 Fluke P5720A/5725A
Range
Required Accuracy*
Calibration Instrument Test to Accuracy Ratio Required
(TAR)
Suggested Calibration Instrument*
Current 0 - 15 ADC 0 - 15
ARMS (40 -
450Hz)
± 0.03 ADC
± 0.03
ARMS
4:1 Fluke 5720A/5725A Fluke 5100B Clarke Hess
Frequency 10 - 450 Hz ± 2.0 Hz
4:1 Fluke 5720A/5725A
Power
0 - 2000 W
(DC, 40 -
± 27.5 W
4:1 Implied with Voltage and Current
0 - 2000 VA
(DC, 40 -
± 30.0 VA
4:1
±1.0 pf (DC, 40 - 450Hz)
± 0.02 pf 4:1
* Calibration instrument accuracy must equal or exceed the listed requirement.
** The resistance required accuracy represents approximately ±2.0°F.
*** Environmental conditions unless otherwise noted are: 73.4ºF ±9 ºF, <70% RH non-condensing.
Appendix J – Calibratable Items - UUT Fixtures
Range
Required Accuracy*
Calibration Instrument Test to Accuracy Ratio Required
(TAR)
Suggested Calibration Instrument*
FT_1105A
(ANC-8)
Fixture P/N:
278237-1
Flow Turbine Meter
0.4 – 7.0 gpm
± 0.4 % 4:1 See Section Aligning\Calibra ting Flow Meter
Appendix J – Calibratable Items - UUT Fixtures
Range
Required Accuracy*
Calibration Instrument Test to Accuracy Ratio Required
(TAR)
Suggested Calibration Instrument*
FT_1105B
(ANC-12)
Fixture P/N:
278242-1
Flow Turbine Meter
1.0 – 10.0 gpm
± 0.4 % 4:1 See Section Aligning\Calibra ting Flow Meter
12 months
* Calibration instrument accuracy must equal or exceed the listed requirement.
*** Environmental conditions unless otherwise noted are: 73.4ºF ±9 ºF, <70% RH non-condensing.
Appendix J – Calibratable Iem – Proof Test Fixture
Calibration Range
Required Accuracy*
Calibration Instrument Test to Accuracy Ratio Required
(TAR)
Suggested Calibration Instrument*
PDT_1102
Fixture P/N:
83769-1
Pressure Transducer
0 - 10 psid ± 0.10 psid Druck DP 510 or Ruska 7250XI
6 months
PT_1102
Fixture P/N:
83769-1
Pressure Transducer
0 - 400 psig ± 4.00 psig Druck DP 510 or Ruska 7250XI
6 months
PT_1103
Fixture P/N:
83769-1
Pressure Transducer
0 - 300 psig ± 3.00 psig Druck DP 510 or Ruska 7250XI
6 months
* Calibration instrument accuracy must equal or exceed the listed requirement.