A-E Synopsis revised 2 Jun 22.docx

DOCX document 19 KB Posted

Attached to
Architect & Engineering (A-E) IDIQ Synopsis Federal contract opportunity
Solicitation number
FA706022R0013
Issued by
Department of the Air Force

View the file

Other files for this federal contract opportunity

Other files attached to Architect & Engineering (A-E) IDIQ Synopsis, newest first.
File Type Posted
Attachment 1 - A-E IDIQ SOW - 14 Feb 22.docx DOCX document
A-E Synopsis.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

A-E IDIQ SYNOPSIS

This Synopsis is for a new specialized Architect-Engineer (A-E) Contract at Joint Base Anacostia-Bolling. The Base Civil Engineering requires Title I, Title II, and Other Architect-Engineer (A-E) services. The successful A-E firm shall be primarily architectural in nature and provide a full range of other engineering disciplines (including, as a minimum, electrical, mechanical, civil, fire protection, environmental, and structural). The Air Force will award one indefinite-delivery indefinite-quantity (IDIQ) contract comprising of a base year with four one year options. The successful A-E firm will be guaranteed a one-time minimum of $2,500.00. The maximum contract amount shall not exceed $9,999,999.99 for the life of the contract. The minimum task order amount is $2,500.00 and the maximum task order amount is expected to be $1,000,000.00. The estimated contract award date will be around the timeframe of September 2022. The general scope of work includes, but is not limited to: site visits, field investigations, development of design analyses, plans, drawings, specifications, cost estimates, other necessary documents for contract accomplishment, and other studies, investigations, and services as required.

SELECTION CRITERIA: The selection criteria are listed below in descending order of importance.

1. Professional qualifications necessary for satisfactory performance of required services. This criterion is primarily concerned with the qualifications of the key personnel and not the number of personnel, which is addressed under the capacity criterion. The lead designer in each discipline must be registered as required by FAR 36.609-4 and 52.236-25, but does not have to be registered in the particular state where the project is located. Offerors are also to include the following:

a. Quality Control Plan: An explanation of the firm's management approach, management of subcontractors (if applicable), quality control procedures, procedures to ensure that internal resources are not overcommitted, and an organizational chart showing the inter-relationship of management and various team components (including subcontractors) in the SF 330. The organization chart shall be no larger than 11" x 17". An 11" x 17" paper will count as one page for the organization chart. In Section H, also indicate the estimated percentage of involvement of each firm on the proposed team. Firms will be evaluated on the acceptability of their internal quality control program used to ensure technical accuracy and disciplined coordination of plans and specifications.

• Quality Control Plan: Limit 10 pages.

b. List key personnel responsible as follows:

• Introduction to resumes: Limit 5 pages.

• Key personnel: Limit 1 individual per category for a total of 6. Offerors’ Key Personnel List shall cover the discipline positions below and provide the minimum information for each person: 1) Years of experience, 2) Projects previously worked.

Program Manager Quality Control Architect Mechanical Engineer Electrical Engineer Civil Engineer

• Personnel resumes: Limit 2 pages per individual.

2. Specialized experience and technical competence in the type of work is required to include, but is not limited to, existing facility renovations and repair, new facilities, pavements, and utility designs, with:

a. Knowledge of Architect and Engineering in the general geographical area of Joint Base Anacostia-Bolling, DC and knowledge of the locality of the project. Examples include knowledge of geological features, climatic conditions or local construction methods that are unusual or unique.

b. Knowledge of Air Force Civil Engineering requirements to include Unified Facilities Criteria and Air Force Policy Directives, Instructions, Pamphlets, Manuals, Technical Data Bulletins and Engineering Technical Letters.

c. Ability to prepare design-build construction contract packages.

d. Knowledge of Air Force requirements for anti-terrorism and force protection design (AT/FP), and comprehensive and structural interior design as well as Customer Concept Documents (CCDs).

e. Knowledge of LEED (Leadership in Energy and Environmental Design) design and construction requirements for buildings.

f. Knowledge of building commissioning with emphasis on mechanical and electrical systems.

g. Knowledge of Unified Facilities Criteria specifications and United States National CAD Standard.

• Specialized Experience and technical competence: Limit 10 pages.

3. Capacity to accomplish multiple task orders up to $1,000,000.00 per task order within the required time frame. Firm's experience with similar size projects and the available capacity of key disciplines when evaluating the capacity of a firm to perform the work in the required time will be considered.

• Capacity: Limit 2 pages.

4. Past Performance:

The US Government will consider and evaluate offeror's past performance information deemed recent and relevant for the requirements of this RFP. The government may use information submitted by the offeror and other sources such as other Federal Government offices, CPARS and commercial sources to assess performance. Recent and Relevant is defined in the subparagraphs below:

Recency: Any completed design work described in the paragraphs above. The effort must be ongoing (50% complete) or must have been completed within the past five (5) years from the date of issuance of this solicitation. Past performance information that is not recent will not be evaluated.

Relevancy: Having successfully completed design work described in the paragraphs above and must have been actively engaged as a contractor, either prime or subcontractor, performing such work with the value of contracts at a minimum of a similar dollar value (at least $250,000.00), physical size, complexity and function, utilizing techniques relevant to those required by this solicitation.

• Sample projects:

- Limit 5 projects, 5 pages each

- Must have been accomplished within the past 5 years

- Provide POC and contact information

5. Firm location (Proximity of firm in general geographic area): Location in the general geographical area of Joint Base Anacostia-Bolling (within 5 hours from Joint Base Anacostia-Bolling) and knowledge of the locality of the installation.

The North American Industry Classification System (NAICS) code for this acquisition is 541330 for Engineering Services; Size Standard is $22.5 million. Contractors must register in the System for Award Management (SAM) database to be eligible for award. You may access SAM at https://www.sam.gov. This acquisition is set-aside for Small Businesses and will be competed using A-E selection procedures in accordance with FAR 36.6, Architect-Engineer Services. This is not a Request for Proposal. Interested A-E firms desiring consideration shall submit the appropriate data described in the Standard Form 330 (SF330), Architect-Engineer Qualifications. All information must be submitted on the SF330, and shall not include other formats referencing the SF330 in lieu of submitting the SF330. Submit a digital copy to casey.morrison.1@us.af.mil and wade.vinje@us.af.mil (note the file cannot exceed 10mb in size and must confirm receipt of SF330), and original with four (4) copies of submittal packages in accordance with the following guidelines/limits for contents:

Format for proposals shall be as follows:

(a) The proposals will be 8 1/2" x 11" paper or standard A4 paper, except for fold-outs used for charts, tables, or diagrams, which may not exceed 11" x 17".

(b) A page is defined as one face of a sheet of paper containing information.

(c) Typing shall not be less than 12 pitch.

(d) Elaborate formats, bindings or color presentations are not desired or required.

The proposal must be received by 27 June 2022 at 2:00PM EDT, To: 11 CONS/PKB Attn: Wade Vinje and Casey Morrison - A-E IDIQ

20 MACDILL BLVD SE, SUITE 460

JOINT BASE ANACOSTIA-BOLLING, DC 20032

File details come from the government source that posted it. Updated .