PERFORMANCE WORK STATEMENT
934TH AIRLIFT WING
FERTILIZATION AND WEED CONTROL SERVICES
1. PROJECT SCOPE
Provide all material, equipment and labor for applications of pre-emergent and post-emergent weed-control herbicides, and fertilizer, to improved grounds of areas N (Main base), the POL and Munitions parcels in Area D, and Area B (Shooting Range) totaling approximately 26 acres. These applications shall occur during specified periods designated by the 934th Airlift Wing. In addition, the Contractor shall provide material, equipment and labor for up to sixty (60) man-hours for application of a non-selective herbicide for fence-lines, sidewalks/curb lines, and pavement joints at locations to be identified by the 934th Airlift Wing’s Civil Engineering Operations representative.
2. QUALIFICATIONS
A. The Contractor must possess a current Fertilizer License issued by the State of
Minnesota, for the following categories: Lawn Service-Ornamental and Custom
Application- Ground.
B. All contractor personnel who perform the application of weed-control herbicides and/or fertilizers on 934th Airlift Wing properties must possess a current
“Commercial Pesticide Applicator” license/certification, issued by the State of
Minnesota, for the following categories:
i. General Ground (Core-Category A)
ii. Turf & Ornamentals (Category B)
3. MATERIALS
A. Pre-emergent herbicide: A commercial-grade pre-emergent herbicide product designed for control of annual weed grasses. Select from approved herbicide products listed on Table 1. Alternative equivalent product(s) may be authorized if prior approval is obtained from the 934th Airlift Wing Environmental Flight.
B. Post-emergent herbicides: A commercial-grade post-emergent herbicide product designed for control of perennial broadleaf weeds and annual weed grasses. Select from approved herbicide products listed on Table 1. Alternative equivalent product(s) may be authorized if prior approval is obtained from the 934th Airlift
Wing Environmental Flight.
C. Non-selective herbicide: Select from approved herbicide products listed on Table
1. Alternative equivalent product(s) may be authorized if prior approval is obtained from the 934th Airlift Wing Environmental Flight.
D. Turf fertilizer: Commercial-grade fertilizer with nutrient ratio of 10-0-10, i.e. ten percent nitrogen, zero percent phosphate, and ten percent potash. Some minor deviation from nitrogen and potash content is allowable.
Table 1. Approved Herbicide Products
Product Name Manufacturer Epa Reg #
Barricade Syngenta 100-1139
Tri-Power Selective Nufarm 228-262
Triplet SF Nufarm 228-312
Razor Nufarm 228-366
TruPower2 Selective Nufarm 228-499
Krenite S DuPont 352-395
Roundup Pro Monsanto 524-475
Trimec Classic PBI Gordon 2217-543
Drive 75 DF BASF 7969-130
Garlon 4 Dow Agrosciences 62719-40
Transline Dow Agrosciences 62719-259
Dimension EC Dow Agrosciences 62719-426
Riverdale TruPower 2 Nufarm 228-419
Spectracide Weed Stop Chemsico 9688-265-8845
4. SUBMITTALS
A. The Contractor shall provide the following submittals before the application of herbicides or fertilizers:
i. Legible copy of company’s Fertilizer License.
ii. Name and driver’s license number of all Contractor employees who will provide services on 934th Airlift Wing property.
iii. Legible copies of Commercial Pesticide Applicator Licenses for each individual that will apply herbicides on government property.
iv. Safety data sheet (SDS) and product specimen labels for any alternative herbicide product proposed for use. These documents can be provided in an electronic format if available from the product’s manufacturer.
B. No later than one week after completion of each or any application, the Contractor shall submit to the Contracting Office clear, legible, and accurate documentation of the actual quantities of each product applied, including water-to-product ratio if product dilutions were made. Application documents shall include:
i. Date of treatment.
ii. Name and license number of Contractor technician(s) performing application.
iii. Product name and EPA registration number of chemical herbicides applied
iv. Quantity of herbicide product applied, in fluid ounces or gallons.
v. Percent active ingredient of product as applied in mixed form.
vi. Dilution ratio of herbicide to water for applied mixture
vii. Area treated per each pesticide (square or linear feet).
5. TENTATIVE EXECUTION SCHEDULE
The 934th Airlift Wing’s Civil Engineering Operations representative and the
Contractor shall jointly establish mutually acceptable specific dates for the following applications and services, within the prescribed date ranges.
A. Pre-emergent/Post-emergent and Fertilizer Application: One (1) application including both pre-emergent and post-emergent herbicides for annual weed grass control and turf fertilizer, to be accomplished during the period from May
1st through June 15th.
B. Post-emergent and Fertilizer – 1st Application: One (1) application including post- emergent herbicides for both annual weed grass control and broadleaf weed control, and turf fertilizer. To be accomplished during the month of July.
C. Post-emergent and Fertilizer – 2nd Application: One (1) application including post- emergent herbicide for only broadleaf weed control, and turf fertilizer. To be accomplished during the period from August 15th through September 15th.
D. Crack/crevice/fence-line treatments: The Contractor shall provide up to sixty
(60) hours of labor for application of a non-selective herbicide for fence-lines, sidewalks/curb lines, and pavement joints, during the period from May 1st through September 15th. The 934th Airlift Wing’s Civil Engineering Operations representative(s) will request service on an as-needed basis.
6. MISECELLANEOUS REQUIREMENTS AND DETAILS
A. The 934th Airlift Wing reserves the right to postpone a scheduled application event if necessary due to unexpected operational mission restrictions, or if forecasted weather conditions are not conducive to successful and effective application of the herbicides and fertilizers (i.e., forecasted or imminent precipitation, or windy conditions). The Contractor shall adhere to:
B. All work on Air Force property will occur between 7:00 AM and 3:00 PM, Monday through Friday excluding any federal holidays.
C. Fertilizer will be applied at a rate that results in, as nearly as possible, an application of 0.5 lbs nitrogen per 1000 ft² and 0.5 lbs potash per 1000 ft².
D. The non-selective herbicide applied for fence-lines, sidewalk/curb lines and pavement joints shall be applied as a minimum 2% concentration. Estimated total amount of product needed for all fence-lines, sidewalk/curb lines and pavement joint applications is 300 gallons, as applied.
E. Preparation and mixing of fertilizers and/or herbicides must be accomplished prior to arrival on 934th Airlift Wing property. Preparation, mixing or storage of fertilizers and/or herbicides on 934th Airlift Wing property is prohibited.
Following each application event, all unused chemicals/products must be removed from 934th Airlift Wing property.
F. The Contractor shall use commonly accepted methods to ensure that herbicide applications do not damage trees and landscaped shrubs and bushes. Trees, shrubs and bushes, or turf areas that are damaged by the Contractor’s equipment or which die due to over-spray or excessive application of herbicides shall be replaced at the Contractor’s expense.
G. The Contractor shall ensure that applications of herbicides and/or fertilizers is accomplished in a manner that minimizes overspray onto non-turf surfaces, and prevents spraying onto buildings, equipment and vehicles owned by the 934th
Airlift Wing.
H. The Contractor shall place standard warning signs or placards onto treated turf areas at locations designated by the 934th Airlift Wing’s Civil Engineering
Operations representative.
PERFORMANCE Paragraph Performance Method of
OBJECTIVE Reference Threshold Surveillance
Apply 100% of Pre & Post On days of
Agreed Request for
Emergent Herbicide Along 5A Upon dates for Specific Dates with Fertilizer Requirement Application on Requested Date
Apply 100% of Post On days of
Agreed Request for
Emergent Herbicide Along 5B Upon dates for Specific Dates with Fertilizer Requirement Application on Requested Date
Apply 100% of Post On days of
Agreed Request for
Emergent Herbicide Along 5C Upon dates for Specific Dates with Fertilizer Requirement Application on Requested Date
Apply Herbicide on On days of
Agreed
Weeds/Grass in cracks, 5D Upon dates for Periodic Inspection
Crevices, and Along Fence Application
Lines as Requested
7. CIVIL ENGINEERING OPERATIONS REPRESENTATIVES
Brian Galles- 612-713-1921
Ted Steidl -612-713-1913
Author: Mr.Ted Trolson 17 Jan 19
5th St
709 710
807805
820 830
803801 80
720 724
5th St nd
Av e S rd
Av e S th
Av e S th
Av e S
Crosstown Service Rd. Crosstown Service Rd.
5th St
Military HwyMilitary Hwy
6th St
2nd St Ea rha rdt
Av e
Kit tyh aw k A ve
1st St
Gr iss om Av e
Lin db erg h A ve
2nd St
Ea rha rdt Av e
Gl en n A ve
5th St
Military Highway
Le Ma y A ve
6th St
Do oli ttle Av e
Ap oll o A ve
MAC Acce ss R d
3rd St
Fuele r Rd
760 761
727725
^MN
ANG
USAFR
USAR
Range
USNR
Officer's Club
§̈¦494§̈¦494
UV62
UV13
UV55
UV5
UV77
MSP
Mississippi River
Minnesota River
MINNEAPOLIS/ST. PAUL ARS GeoBase934th Airlift Wing Turf Management 1:2,700
0 150 30075 Feet 1 inch = 225 feet
Building
Paved Surface Unpaved Surface
Fence Wall
Gate
Airfield The "Management Area" shown on the map is a generalization of the overall area for Turf Managment. The acreage estimate and areas for management are not intented to be authoritative but as a general guide.
Management Area
1.3 Acres - Estimated POL Management Area
AREA D (Air Guard)
DATA SOURCE: MINNEAPOLIS/ST. PAUL ARS GEOBASE
NAD 1983 StatePlane Minnesota South FIPS 2203 Feet
THIS MAP IMAGE WAS PRODUCED THROUGH THE U.S. DEPARTMENT OF DEFENSE (DOD)
OFFICE OF THE UNITED STATES AIR FORCE RESERVE COMMAND (AFRC) BY THE
MINNEAPOLIS/ST. PAUL AIR RESERVE BASE CIVIL ENGINEERING DEPARTMENT -
MINNEAPOLIS, MN. ALL IMAGERY IS THE SOLE PROPERTY OF THE UNITED STATES
GOVERNMENT AND IS NOT TO BE REPRODUCED WITHOUT THE CONSENT OF THE OFFICE
OF THE AFRC. SUCH AN ACT WILL BE A CLEAR VIOLATION OF U.S. COPYRIGHT LAWS.
MINNEAPOLIS/ST. PAUL ARB CIVIL ENGINEERING DEPARTMENT SHALL NOT BE LIABLE
FOR ERRORS, OMISSIONS OR DAMAGES THAT RESULT FROM INAPPROPRIATE USE OF
THIS DOCUMENT. THIS DOCUMENT IS A DRAFT COPY AND IS SUBJECT TO CHANGE.
F
Munitions
POL
Front Gate
21.7 Acres - Estimated Main Base Management Area
0.3 Acres - Estimated Front Gate Turf Management Area
1.1 Acres - Estimated Muntions Management Area
24.4 Acres - Estimated Total Management Area