This document is an attachment describing the technical specifications for a Secure Weapons Storage Vault required under a federal contract opportunity. The vault must be capable of securely storing at least 15 GAU-2s, 15 GAU-18s, 18 GAU-21s, and 10 Sig Sauer M18s, with a total size of approximately 30ft x 10ft x 10ft. Key requirements include a Vindicator Intrusion Detection System, an HVAC system to maintain environmental controls, a 220v 100amp 50Hz power supply, and optional mobility features. The contract opportunity is being issued by the Department of the Air Force United States Air Forces in Europe - Air Forces Africa for delivery to Aviano Air Base in Italy. The solicitation number is FA568224Q7001, and the opportunity is subject to the availability of appropriated funds.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SILENT CARACHTERISTICS

2 April 2024

ITEM DESCRIPTION:

-N. 1 Secure weapons storage vault (ARMAG or equivalent)

Capacity and Configura�on: Must include weapon racks capable of securely storing at least 15 GAU-2s, 15 GAU-18s, 18 GAU-21s, and 10 Sig Sauer M18s. The configura�on should allow for easy access and inventory management while ensuring maximum space u�liza�on.

Size: approximately 30ft X 10ft X 10ft

Security System: Equipped with a Vindicator Intrusion Detec�on System, ensuring real-�me security monitoring with both visual and audible alarms. This system must be capable of integra�on with exis�ng base security protocols and networks.

Environmental Controls: Must feature an HVAC system to maintain a controlled environment within specific temperature and humidity ranges to prevent corrosion or damage to stored weapons.

Addi�onally, a dehumidifier and lightning protec�on kit, including 2 NFPA ground kits, are required to protect against environmental hazards.

Power Requirements: The vault must be compa�ble with 220v, 100amp, 50Hz power supply (European standards) and include an external disconnect for hardwiring.

Installa�on and Mobility: While not required to be permanently bolted to the ground, the vault should include (4) anchor brackets with concrete anchor bolts for op�onal securing. Mobility for reloca�on without compromising security or integrity is essen�al.

Ancillary Features: Includes (2) work benches with butcher block tops for maintenance and inspec�on ac�vi�es, ensuring func�onality aligns with opera�onal needs.

Drawings: See atachment