Question and Answer regarding Input/Output

Question:

Will all 12 Outputs need to be active at a given time since there are only 9 Inputs? Stated differently, do multiple Outputs need to be connected to a single Input?

Answer:

Per the technical requirements, this matrix switch (crossbar type) has to be able to uniquely match any input to any input uniquely and in a 1:1 ratio. Not all outputs will be active at a given time but all outputs be available to be matched.