Presolicitation Notice.pdf

PDF 140 KB Posted

Attached to
Trailer Mounted 1000kW Load Bank
Solicitation number
FA5613A003
Issued by

About this file

PRESOLICITATION NOTICE SUMMARY

This is a Presolicitation Notice for a Trailer Mounted 1000kW Load Bank issued by 700 CONS/PKA, Kapaun Air Station, Kaiserslauterns, Germany. The requirement is for a mobile, high-capacity load-absorbing unit designed for durability and safe transport. The load bank must accept medium-voltage inputs of 2400V and 4160V with adjustable load steps up to 1000 kW to enable full-load generator testing. The unit requires integrated cooling and over-temperature protection, digital monitoring for real-time display of voltage, current, frequency, and power factor, and must be mounted on a road-ready trailer equipped with stabilizing outriggers. Additional specifications include weather-resistant enclosures, secure access panels, compliant grounding, medium-voltage connection points, safety interlocks for proper operation with BPUs, and capability for continuous full-load operation under varying environmental conditions.

The anticipated award date is 30 September 2026. No set-aside applies due to the overseas location per RFO 19.000(b)(1)(ii). The NAICS code is 811310 and the Product Service Code is 6150. Commercial items will be evaluated using the most advantageous to government approach. All responsible sources may submit quotations, bids, or proposals subject to World Trade Organization Government Procurement Agreement and Free Trade Agreements per RFO 52.225-5. Points of contact are Contracting Specialist Jonathan Rushin (jonathan.rushin@us.af.mil, 314-489-0080) and Contracting Officer Tre Fontenot (autry.fontenot.2@us.af.mil, 314-489-6787). This notice is for information purposes only; quotes, bids, or proposals submitted in response will not be considered for award.

View the file

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PRESOLICITATION NOTICE

Trailer Mounted 1000kW Load Bank

From: 700 CONS/PKA

Bldg 2767, Kapaun Air Station D-67661, Kaiserslautern

POCs:

Contracting Specialist: Jonathan Rushin

E-mail: jonathan.rushin@us.af.mil

TEL: 314-489-0080

Contracting Officer: Tre Fontenot E-mail: autry.fontenot.2@us.af.mil

TEL: 314-489-6787

Notice to Offeror(s)/Supplier(s):

This document is to serve as a Pre-solicitation notice only. Do not provide quotes, bids, or proposals as they will not be considered for award. No contract will be made in response to this notice.

Anticipated award date 30 September 2026

Due to the overseas location of this requirement, no set-aside will be used in accordance with RFO 19.000(b)(1)(ii). The North American Industry Classification System (NAICS) code associated with this requirement is 811310. The Product Service Code (PSC) is 6150. Evaluation of commercial items in accordance with RFO 52.212-2 will be utilized using most advantageous to the government.

Once solicited, all responsible sources may submit a quotation, bid, or proposal, as appropriate, which will be considered by the agency subject to the World Trade Organization. IAW RFO 52.225-5, Trade Agreements, one or more of the items under this acquisition, is subject to the World Trade Organization Government Procurement Agreement and Free Trade Agreements.

Description of Requirement:

Must be a mobile, high-capacity load-absorbing unit designed for durability, safe transport

Load bank must accept medium-voltage inputs of 2400V and 4160V and provide adjustable load steps up to 1000 kW to enable full-load generator testing.

Must include integrated cooling, and over-temperature protection

Digital monitoring for real-time display of voltage, current, frequency, and power factor.

The system shall be mounted on a road-ready trailer equipped with stabilizing outriggers, Weather-resistant enclosures, and secure access panels.

Unit must include compliant grounding, medium-voltage connection points, and safety interlocks to ensure proper operation with BPUs.

The load bank must be capable of continuous full-load operation under varying environmental conditions

File details come from the government source that posted it. Updated .