RFP_Atch_3b_-_Bldg_2167_Disposal_Concept.xlsx

XLSX spreadsheet 21 KB Posted

Attached to
Multiple Award Construction Contract (MACC) Federal contract opportunity
Solicitation number
FA5613-19-R-0003
Issued by
Department of the Air Force United States Air Forces in Europe - Air Forces Africa

About this file

This document provides details regarding a Multiple Award Construction Contract solicitation to be issued by the 700th Contracting Squadron, Kapaun Air Station, Germany. The solicitation seeks proposals for indefinite-delivery, indefinite-quantity construction contracts valued at an estimated $425 million over five years. The contracts will be for design-build, sustainment, maintenance, alteration, repair, renovation, and minor construction projects affecting real property at federal and military installations within the Kaiserslautern Military Community and Ramstein and Spangdahlem Air Bases in Germany. Individual task orders will be on a firm-fixed-price basis for work descriptions identified in each order, ranging from $1,000 to $5 million. A design-build seed project valued between $1 million and $5 million is included at Ramstein Air Base. The solicitation is anticipated for issue on November 1, 2018 with proposals due December 1, 2018. The Department of the Air Force United States Air Forces in Europe - Air Forces Africa will award up to five contracts with two additional on-ramp contractors available if needed.

RFP Atch 3b - Bldg 2167 Disposal Concept

View the file

Other files for this federal contract opportunity

Other files attached to Multiple Award Construction Contract (MACC), newest first.
File Type Posted
FA5613-19-R-0003-0004.pdf PDF
(Amend_0004)_Section_L.pdf PDF
(Amendment_0004)_Section_M.pdf PDF
Consolidated_Q&A__6.pdf PDF
Consolidated_Q&A__5.pdf PDF
Atch_3k_-_Drinking_Water_Analysis.pdf PDF
RFP_Atch_3_-_(Rev_3_)_SOW_for_Seed_Proj_TYFR18-1047.pdf PDF
Consolidated_Q&A__3.pdf PDF
RFP_Atch_3i_-_Noise_Contour_Map_RAB.pdf PDF
RFP_Atch_3_-_(Rev_2)_SOW_for_Seed_Proj_TYFR18-1047.pdf PDF
RFP_Atch_3g_-_(Rev_1)_Shelf_Layouts_and_Dimensions.pdf PDF
FA5613-19-R-0003-0002.pdf PDF
RFP_Atch_3g_-_Shelf_Layouts_&_Dimensions.pdf PDF
FA5613-19-R-0003-0001.pdf PDF
RFP_Atch_5e_-_Premise_Wiring_Standard.pdf PDF
RFP_Atch_3_-_(Rev_1)_SOW_for_Seed_Proj_TYFR18-1047.pdf PDF
Atch_3_-_Pre-Prop_Conf_&_Site_Visit_Briefing.pdf PDF
Atch_1_-_Conf_&_Site_Visit_Attendance_Record.pdf PDF
Atch_2_-__Consolidated_Q&A_2_(Conf_&_Site_Visit).pdf PDF
Pre-Proposal_Conference_Minutes.pdf PDF
RFP_Atch_3f01_-_Cover,_TOC,_location_plan.dwg DWG drawing
RFP_Atch_3f01_-_Cover,_TOC,_location_plan.pdf PDF
RFP_Atch_8_-_SubK_Consent_Ltr.doc DOC document
RFP_Atch_3_-_SOW_for_Seed_Proj_TYFR18-1047.pdf PDF
RFP_Atch_3f03_-_B02_-_Inventory_topview.dwg DWG drawing
RFP_Atch_3f05_-_B04_-_Inventory_elevations.pdf PDF
RFP_Atch_5a_-_Standardized_Technical_Proposal_(STP).pdf PDF
Invitation_for_Pre-Proposal_&_Conf_Site_Visit.pdf PDF
RFP_Atch_3e_-_Bldg_2167_Work_and_Safety_Plan.docx DOCX document
RFP_Atch_3f06_-_A01_-_New_planning_floor_plan.dwg DWG drawing
RFP_Atch_1_-_General_Requirements_&_Provisions.pdf PDF
RFP_Atch_3f06_-_A01_-_New_planning,_floor_plan.pdf PDF
RFP_Atch_3a_-_Bldg_2167_Contaminant_Investigation_Report.docx DOCX document
RFP_FA5613-19-R-0003_(MACC).pdf PDF
RFP_Atch_2_-_Special_Contract_Requirements.pdf PDF
RFP_Atch_3f04_-_B03_-_Inventory_sectional_views.pdf PDF
RFP_Atch_5b_-_LD_Determination.pdf PDF
RFP_Atch_3d_-_Bldg_2167_Sample_Taking_Plan.pdf PDF
Cover_Ltr_-_RFP_Release.pdf PDF
RFP_Atch_3f04_-_B03_-_Inventory_sectional_views.dwg DWG drawing
RFP_Atch_4_-_Seed_Proj_Bid_Schedule_Worksheet.xlsx XLSX spreadsheet
RFP_Atch_3f03_-_B02_-_Inventory_topview.pdf PDF
RFP_Atch_6_-_PPI.doc DOC document
RFP_Atch_9_-_Client_Authorization_Ltr.docx DOCX document
RFP_Atch_7_-_PPQ.doc DOC document
RFP_Atch_3c_-_Bldg_2167_Room_Book.xls XLS spreadsheet
RFP_Atch_3f02_-_B01_-_Inventory_floor_plan.pdf PDF
RFP_Atch_5c_-_Material_Submittal_Form_66_TYFR_18-1047.pdf PDF
RFP_Atch_3f02_-_B01_-_Inventory_floor_plan.dwg DWG drawing
Invitation_Atch_1_-_PreRegistration_Form.docx DOCX document
Show all 50

Multiple Award Construction Contract (MACC) has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Non-hazardous waste

No.Waste materialWaste codesClassificationContaminantIncidenceDeterminedWaste quantityUtilization/RecyclingNote
(recommendation)as per AVVClassificationContaminant contentsestimatedDisposal
as per LAGA
1Used equipmentnon-hazardousElectrical distribution
electronic, that contains16 02 14wastepanels and cabinets< 2 toutilization
no hazardous materialsother equipment
2Insulation materialnon-hazardousSound insulating panels
without hazardous17 06 04wastenon-contaminated styrofoam and< 0,5 tomaterial or thermalSmall quantities of non-contaminated insulation
substancesstyrodur insulationutilizationmaterials can also be utilized as
foamed insulation, etc.mixed construction waste 17 09 04.
3Mixed construction andnon-hazardousMixed waste, refuse
demolition waste17 09 04wastedirty foils, textiles< 20 toutilizationMixing with hazardous materials
without hazardousnon-contaminated flooringsis not allowed.
substancesnon-cont. foams, equipment etc.
therm. insul. composite systems
non-cont. floor sealing coats(Separation).
4Cables withoutnon-hazardousElectrical lines,
hazardous substances17 04 11wastecables< 2 tometal utilization
5.1.Iron and steel170405non-hazardousSteel pipes, mechanical,depending on
wastereinforcement, pipingconstructionmetal utilization
5.2.Mixed metals170407non-hazard. wasteFixtures , piping< 0,5 tometal utilization
6.1.1.Mixed constr. debris withoutnon-hazardousParameters IAWTiles, ceramics, bricksutilization
or with only littlewasteLAGA constr. debriswalls, ceilingsdepending onDeclaration analysis after demolition
contamination17 01 07LAGA Z 0 toplaster, ceramicconstructionis required.
up to LAGA Z 1.2.LAGA Z 1.2floorings, screed etc.
6.1.2.Mixed constr. debris withoutnon-hazardousParameters IAWTiles, ceramics, bricksdisposal
or with only littlewasteLAGA constr. debriswalls, ceilingsSulfate valuesdepending onDeclaration analysis after demolition
contamination17 01 07LAGA Z 0 toplaster, ceramichigher than (>) Z2constructionis required.
up to LAGA Z 1.2.LAGA Z 1.2floorings, screed etc.
6.2.Concrete17 01 01non-hazardousLAGA Z 0 toConcrete, floor slab, lintelsdepending onutilizationDeclaration analysis after demolition
wasteLAGA Z 1.2concrete beams, foundationconstructionis required.
6.3.1.Mixed constr. debris withoutnon-hazardousParameters IAWTiles, ceramics, bricksutilization
or with only littlewasteLAGA constr. debriswalls, ceilingsdepending onDeclaration analysis after demolition
contamination17 01 07LAGA Z2plaster, ceramicconstructionis required.
LAGA Z 2floorings, screed etc.
6.3.2.Mixed constr. debris withoutnon-hazardousParameters IAWTiles, ceramics, bricksdisposal
or with only littlewasteLAGA constr. debriswalls, ceilingsSulfate valuesdepending onDeclaration analysis after demolition
contamination17 01 07LAGA Z2plaster, ceramichigher than (>) Z2constructionis required.
LAGA Z 2floorings, screed etc.
No.Waste materialWaste codesClassificationContaminantIncidenceDeterminedWaste quantityUtilization/RecyclingNote
(recommendation)as per AVVClassificationContaminant contentsestimatedDisposal
as per LAGA
6.4.Concrete17 01 01non-hazardousConcrete, floor slab, lintelsdepending onutilizationDeclaration analysis after demolition
wasteLAGA Z2concrete beams, foundationconstructionis required.
7Construction materials onnon-hazardousGypsum plaster boardsdepending onAs gypsum is made of calcium sulfate,
gypsum basis without17 08 02waste(aerated concrete masonry)constructiondisposaldo not mix with "normal" construction debris
hazardous contamination(gypsum blocks)as otherwise the sulfate values will be high.
8Soil and stones without17 05 04non-hazardousLAGA Z 0 toExcavation of soildepending on
or with only littlewasteLAGA Z2in outdoor areaconstructionutilizationDeclaration analysis after demolition
contaminationParameters IAWis required.
up to LAGA Z 2LAGA soil
9Biologically degradablenon-hazardousGreen wastedepending onutilization
waste20 02 01wastewood from treesconstructioncompostingAny foreign matter shall be sorted out.
in the outdoor area
10Glass17 02 02non-hazardousWindow glassdepending onSmall quantities of waste glass
wastedoor glassconstructionutilization / recyclingmay also be utilized as mixed construction
other waste glassdebris 17 09 04.
11Wood A1-A317 02 01non-hazardousNon-treated wood in
wastethe indoor area< 2 toutilization / recyclingWaste wood shall be clean and not
contamianted (with foreign matter).
12Plastics17 02 03non-hazardousCable ductsSmall quantities of plastics
wastelight-fixture covers< 1 toutilization / recyclingmay also be utilized as mixed construction
foils, other plasticswaste 17 09 04.

&"Arial,Fett" Disposal concept - Non-Hazardous Waste to the report: Contaminant Investigation Building 2167 Ramstein Air Base

Hazardous waste

No.Waste materialWaste codesClassificationContaminantIncidenceDeterminedWaste quantityUtilization/ DisposalNote
(recommendation)as per AVVClassificationcontaminantestimated
as per LAGAcontents
1Other insulation materialsRespirableMaterials containing mineral fibers
consisting of hazardous17 06 03Hazardous wastefibers IAWat pipings, mechanical systems,Ki-value < 30< 5 tdisposalPacking in mineral wool bags
substances or containingas Ki-value < 30WHO-definitionsuspended ceilings, wall and
such substancesceiling linings, in light-weight walls
2Asbestos-containing17 06 05HazardousAsbestosVinyl asbestos flooringsdisposalRemoval of contaminated floorings
construction materialswasteasbestos-containing seals< 5 tconsolidation of materials
packing in big bags
3Transformers andCapacitorsUndestroyed dismounting!
capacitors containing16 02 09Hazardousin old fluorescent light-fixtures,< 50kgdisposal(break-proof storing in the prefabricated
PCB or PCTwasteold transformerscontainers of the transport company)
4Fluorescent tubesHazardousFluorescent tubesUndestroyed dismounting!
and other20 01 21wastein fluorescent light-fixtures< 50kgdisposal(break-proof storing in the prefabricated
mercury-containing wastecontainers of the transport company)
5Electrical equipmentNew equipment does not contain PCB
with hazardous components16 02 13HazardousBatteries of emergency light-fixtures< 50kgutilizationand asbestos, however other hazardous
(without PCB)wastematerials that should be utilized/
recycled by a specialist company, except
for mateials allocated to 160209 - 160212
6Wood withHazardousLacquered woodTreated wood, lacquered furniture
hazardous substances17 02 04wastewood preservativelacquered wooden doors, wooden panels< 5 tothermalClassification as per the acceptance
AIV - woodflame retardants(boards, laths, wooden frames, beams)utiliizationcriteria of the recycling company

&"Arial,Fett" Disposal Concept - Hazardous Waste to the report: Contaminant Investigation Building 2167 Ramstein Air Base

Tabelle3

File details come from the government source that posted it. Updated .