Text version
Questions and Answers
Fluorescent Penetrant Inspection Unit
1. Station 3 references a Water Heater 50 – 100 °F Shared with Station 5. What specific type of water heater do they require gallon capacity?
Answer: This is a mistake, a water heater is not required. The facility provides heated water to support our requirements.
2. Station 3, 4, 5 references (see DWG) I see no drawing attached?
Answer: The requested drawing is attached
3. Carbon Filter system, is there a specific capacity you require?
Answer: We would need at least a 50 gallon capacity of waste water.
4. Will the government consider milestone payments for this project?
Answer: Not for this project
5. Is there a reason you don’t want to use government provided transportation from the consolidation point?
Answer: To alleviate the possibility of damage/delays that can delay installation and testing of this requirement
File details come from the government source that posted it.