Specifications for Human Presence Heartbeat Detection Systems 48th Contracting Squadron

RAF Lakenheath, United Kingdom

Contractor shall provide a quote for system in accordance with the following:

a. 2 Each Human Heartbeat Detection systems including accessories as follows:

System detects the presence of individuals located in vehicles or containers using from vibrations caused by the human heartbeat and blood flow through the body.

Two (2) portable heartbeat detection systems which includes Supply of a CMS Cable Reel System:

1 Null Modem RS-232 Cable, 1 10’ USB Cable, 2 Ground Sensor Cables, 5 Vehicle Sensor Cables, 6 Sensor Cables, 1 10 ft. USB Cable, 1 Cable Management System with 5 cable reels.

4 sensitivity levels, Control box, and is operated through the use of a provided rugged touchscreen computer pre-loaded with software.

Voltage shall be AC 100V-240V 50/60Hz, auto sensing/switching worldwide power supply 12 month service package for the new heartbeat system. 2 preventative maintenance visits per year. Next working day response to call-outs. Free loan of spare sensors and cables while yours are being repaired

b. 2 Each Cable Management Reel Systems as follows:

A cable management reel system to support operation of the human presence heartbeat detection system.

Cable management reel systems shall be attached to interior wall of large vehicle inspection station bays.

c. Delivery, Installation, and training as follows:

Delivery, installation, and operator training for 5 personnel.

Ensures system operates in accordance with manufacture specifications.

Maintains 100% operational readiness status.