Attachment_2_-_Laser_Etcher_SOO.pdf

PDF 113 KB Posted

Attached to
Laser Etcher
Solicitation number
FA558718Q0071
Issued by

About this file

Attachment 2 - Laser Etcher SOO

View the file

Other files

File Type Posted
Combo_-_Laser_Etcher.pdf PDF
Attachment_1_-_Quote_Sheet_Laser_Etcher.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DEPARTMENT OF THE AIR FORCE

48TH FIGHTER WING (USAFE)

For Official Use Only (FOUO)

7 May 2018

MEMORANDUM FOR WHOM IT MAY CONCERN FROM:

48 EMS/MXMFA

SUBJECT: Statement of Objective for Fiber Laser Etcher

1. Requirements/specifications are as follows:

A. Standard features

a. Air Cooled, Solid State Pulsed Ytterbium Fiber Laser

b. 3.0” High Resolution Lens

c. High Speed Servo Motor Control System

d. Red Dot Pointer

e. installation and training

f. Air Assisted Pump

g. Oracle IQ software

h. 815MM x 508MM bed size (32”X20”)

i. Fully Vented/ Filtered Extraction unit

j. Fully Programmable software

k. 30-50 Watt Laser

l. Machine size overall dimensions: (52.5”X33.75”X40.75”)

m. Maximum Material Thickness: 12.5”

n. Maximum Table Weight (capacity): 200lbs

o. Multiple file Storage up to 64MB

p. Laser Dashboard included

q. Manually Adjustable Home Locator for larger items

r. Three Modes: Raster, Vector, and Combined (Raster and Vector)

s. High-Speed, continuous loop, DC servomotors using linear and rotary encoding technology for precise positioning.

t. User controlled resolution from 75 to 1200 DPI

u. Auto switching power supply accommodates 110 and 240 volts, 50 or 60 Hz, Single Phase

v. 10-Base T print interface Ethernet and USB connection,

w. Compatible with windows XP/Vista/7/8/10.

B. Specifications

B1. Laser

a. 50 Watt Fiber Laser

b. Air Cooled, Solid State Pulsed Ytterbium Fiber Laser

c. Red Dot Pointer

B2. Cabinet

a. Bed Size: 815MM X 508MM (20”X32”)

b. Cabinet dimensions: (52.5”X33.75”X40.75”)

c. Max Bed Weight: 200LBS

d. overall weight 500LBS

e. Max Material Thickness: 12.5”

B3. Electricity

a. Auto switching power source 110 or 240 Volt

b. Servomotor Type: DC

c. 50 or 60Hz

d. Single Phase

C. Etching Requirements B1. Must be able to etch the following materials

a. 17-4 PH Stainless Steel

b. 303 Stainless Steel

c. 4043 Steel

d. 6061 Aluminum

e. Yellow Chromate Aluminum

f. Black/White Polycarbonate

g. Brass

h. Brushed Aluminum

i. Carbon Fiber

j. Metal Plated Ceramics

k. Clear Coated Anodized Aluminum

l. Cobalt Chrome Steel

m. Copper

n. GE Plastics polycarbonate resin 121-R

o. Hard Coated Anodized Aluminum

p. Inconel Metals (Various)

q. Machine Tool Steel

r. Magnesium

s. Nickel Plated 1215 Mild Steel

t. Nickel Plated metals (Brass, Gold, & Steel)

u. Nylon

v. Silicon Carbide

w. Silicon Steel

x. Zinc Plated Mild Steel

y. Acrylonitrile Butadiene Styrene (ABS) Plastic

3. Contractor requirements: Contractor shall provide all materials, transport, labor, etc. to supply the following: Epilog Laser Etcher and accessories/hardware, to include freight, installation, setup, and training at customer location. They must also include standard warranty of 12 months on mechanical and electrical components with 24 months warranty on the tube (laser source) from installation date.

Point of contact. The contractor shall designate in writing a single point of contact to the contracting office for any maintenance service required under this contract. This information shall include name, title, address, and telephone number.

Telephone Assistance. The contractor shall provide telephone assistance during business hours 0800 hrs through 1600 hrs GMT for equipment covered under this contract excluding Federal/British holidays. The designated government point of contact (POC) shall be able to call and receive assistance.

Updates. The contractor shall provide all updates to include: installing manufacturer designed and issued field modifications, safety corrections, and revisions for correcting equipment deficiencies. The contractor shall provide adequate training on the equipment and in conjunction with any required modifications made by the contractor IAW manufacturer’s recommendation or to support industry standards.

Normal hours of call out coverage are Monday through Friday, 0700-1600 hrs, excluding Federal/British holiday. All service/repairs shall be performed during normal hours of coverage unless requested or approved by the designated government POC. Response Time: The contractor must respond with a phone call to the designated government POC within 1 business day after telephone notification. If the problem cannot be corrected by phone, the contractor will commence work on-site during normal hours of coverage.

United States Federal holidays observed.

Federal British holidays observed.

CASEY P. CHEFF, TSgt, USAF Corrosion Control NCOIC