Attachment 1 - Statement of Requirements (SOR) - Ballistic Towers Remediation.pdf

PDF 209 KB Posted

Attached to
RFQ - 409 ESFS Ballistic Towers Remediation (Amendment 0001)
Solicitation number
FA542223Q1002
Issued by

About this file

This Statement of Requirements outlines equipment and services needed to remediate ballistic perimeter towers at Air Base 201 in Niger. The United States Air Force requires 29 pedestal assemblies with pintles, 28 swing arms, 29 machine gun cradle assemblies, 44 sliding gunports, and 7 light carts for increased visibility. Additional items include gas springs, HVAC systems, electrical components, tools, safety equipment and supplies for installation and maintenance. Delivery is required to a consolidation point at Dover Air Force Base by the date specified in Solicitation FA542223Q1002. The contractor must provide standard commercial warranties and documentation for all equipment, as well as procedures for technical support and replacement of faulty items.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Statement of Requirements 409 Expeditionary Security Forces

Squadron (ESFS) Ballistic Perimeter Tower Remediation

18 July 2023

1.0 PURPOSE. The purpose of this requirement is to purchase heavy weapon mount assemblies and ballistic shields for gun ports, along with tools and parts to enhance the life support systems at the ballistic perimeter towers, as well as light carts to increase visibility and nighttime detection capability for the 409 ESFS on Air Base 201, Agadez, Niger.

2.0 DESCRIPTION OF ITEMS. The mounts shall be compatible with Machine Gun

(M)240/M249 weapon systems and have a cradle assembly to hold ammunition containers containing either 5.56 or 7.62 millimeter (MM) linked belt fed ammunition. The gun ports shall be National Institute of Justice Level IV (.30-06 armor piercing) tested and approved to maximize protection of personnel. The light carts shall have their own standalone power supply and mobile (ability to be pulled by a vehicle).

2.1. Ballistic Perimeter Tower Equipment:

2.1.1 PEDESTAL ASSEMBLY WITH PINTLE (QUANTITY [QTY]: 29)

2.1.2. SWING ARM (QTY: 28)

2.1.3. LIGHT MACHINE GUN CRADLE ASSEMBLY (QTY: 29)

2.1.4. SLIDING GUNPORT (QTY: 44)

2.1.5. LIGHT CARTS (QTY: 7)

2.2. Item(s) required for installation.

2.2.1. HEXAGON (HEX) HEAD CAP SCREW: 5/8”-11, STAINLESS STEEL,

(QTY: 20)

2.2.2. FLAT WASHER: 5/8’-11, STAINLESS STEEL (QTY: 200)

2.2.3. HEX NUT: 5/8’’-11 THREAD SIZE, 15/16’’ WIDTH (WD) ACROSS FLATS

(QTY: 4)

2.2.4. 29 PIECE (PC) JOBBER LENGTH DRILL SET (QTY: 1)

2.2.5. CUTTING OIL: 16 OUNCE (OZ) CAN (QTY: 12)

2.2.6. GAS SPRING: STANDARD (STD), 250 POUND (LB), STEEL, ROD

THREAD SIZE METRIC (M)8 ROD THREAD SIZE, 10.36’’ COMPRESSED

(COMP) LENGTH (LG) (QTY: 48)

2.2.7. GAS SPRING HINGE EYE: 8.2MM HOLE, LG 20MM, M8 THREAD (QTY:

48)

2.2.8. GAS SPRING BALL SOCKET: 10MM BALL SOCKET 19MM M8 THREAD

(QTY: 48)

2.2.9. GAS SPRING BRACKET: 10MM BALL (QTY: 96)

2.2.10. GAS SPRING BRACKET: QUICK FASTENER 8MM (QTY: 96)

2.2.11. SINGLE-ZONE SPLIT SYSTEM WITH HEAT PUMP: 23,500 BRITISH

THERMAL UNITS PER HOUR (BTUH) (QTY 10)

2.2.12. TUBING: COPPER, 5/8’’, 50 FEET (FT), COIL (QTY 10)

2.2.13. TUBING: COPPER, 3/8’’, 50 FT, COIL (QTY 10)

2.2.14. 250 FT RUBBER PORTABLE CORD: 3 CONDUCTORS, 10 AMERICAN

WIRE GAUGE (AWG), 600V (QTY: 2)

2.2.15. 250 FT RUBBER PORTABLE CORD: 3 CONDUCTORS, 12 AWG, 600V

(QTY: 4)

2.2.16. MULTI-BIT SCREWDRIVER: TIP SIZES: #1; #2, 1/4”; 3/16”; 3/8”; 5/16”;

4MM; TORX: T10;T15 (QTY: 10)

2.2.17. MULTI-BIT SCREWDRIVER: TIP SIZES: #0; #00; 1/8”; 5/32” (QTY: 18)

2.2.18. PIPE INSULATION: FITS 3/8” AND 5/8” TUBE, ¾” WALL, INSULATION

RATING -70 TO 220 (QTY: 28)

2.2.19. PIPE INSULATION: FITS 5/8” PIPE & TUBE, 1” WALL, INSULATION

RATING -70 TO 220 (QTY: 28)

2.2.20. LOCKING PLUG: L6-30P, 250 VOLT (V) ALTERNATING CURRENT (AC),

30A, 2 POLES (QTY: 10)

2.2.21. TORPEDO LEVEL: 9”, 3 VIALS, TOP READ, ALUMINUM (ALUM),

MAGNETIC (QTY: 3)

2.2.22. WIRE STRIPPER: 18 AWG TO 8 AWG, 7 ¾” (QTY: 3)

2.2.23. HEX KEY SET: SHAPE: L, METRIC AND SOCIETY OF AUTOMOTIVE

ENGINEERS (SAE), 22 PC, PLASTIC HOLDER (QTY: 3)

2.2.24. ADJUSTABLE WRENCH SET: 1-1/4” JAW WD CAPACITY (QTY: 3)

2.2.25. MAGNETIC DRILL PRESS: VARIABLE SPEED, 450-590 REVOLUTION

PER MINUTE (RPM), 120 V (QTY: 1)

2.2.26. ANNULAR CUTTER: 5/8”, 1” MAXIMUM (MAX) CUTTING DEPTH (DP)

(QTY: 5)

2.2.27. ACETYLENE GAS TANK, 10 CUBIC FEET (CF) (QTY: 4)

2.2.28. ARGON GAS TANK, 112 CF (QTY: 2)

2.2.29. OXYGEN GAS TANK, 20 CF (QTY: 2)

2.2.30. TORCH CUTTING/WELDING OUTFIT: FUEL: ACETYLENE, STDS:

EDISON TESTING LABORATORIES/INTERTEK TESTING SERVICES (ETL)

OR UNDERWRITERS LABORATORIES (UL) (QTY: 2)

2.2.31. 20 AMPERES (A) WALL SWITCH (QTY: 20)

2.2.32. EXPOSED WORK ELECTRICAL BOX COVER; ½” DP, 4” WD (QTY: 20)

2.2.33. 20A - 125V RECEPTACLE OUTLETS (QTY: 30)

2.2.34. RECEPTACLE OUTLETS COVER (QTY: 30)

2.2.35. DOUBLE (DBL) GANG WET LOCATION OUTLET BOX ½” HOLE (QTY:

30)

2.2.36. DBL GANG OUTLET COVER (QTY: 30)

2.2.37. ½’’ PLASTIC BOX CONNECTORS (QTY: 100)

2.2.38. WET LOCATION JUCTION BOXES 100 X 100 X 70 MM (QTY: 20)

2.2.39. LIGHT-EMITTING DIODE (LED) UNDER CABINET LIGHTING: 32”,

PLUG-IN OR DIRECT WIRE (QTY: 20)

2.2.40. 15 A 125 V STRAIGHT BLADE PLUG (QTY: 20)

2.2.41. 3 CONDUCTOR 12AWG 100FT LG 300V, (QTY: 6)

2.2.42. ELECTRICAL BOX: GALVANIZED ZINC, 2 1/8” (QTY: 50)

2.2.43. EXPOSED WORK ELECTRICAL BOX COVER: SHAPE: SQUARE, 2

GANGS (QTY: 30)

2.2.44. LIQUID TIGHT CORD CONNECTOR: NYLON, ¾” MALE NATIONAL PIPE

THREAD (MNPT), .45 TO .71” (QTY: 100)

2.2.45. 50 FT NYLON BUILDING WIRE: 12 AWG, 1 CONDUCTOR (QTY: 1)

2.2.46. GROUNDING SCREW: STEEL, GREEN (QTY: 1)

2.2.47. CABLE TIES: .27” WD (QTY: 4)

2.2.48. LED ROPE LIGHT: RED, 18 FT (QTY: 20)

2.2.49. LED ROPE LIGHT: WHITE, 18 FT (QTY: 20)

2.2.50. 120 V 12 A HAND HELD BELT SANDER: 4X24” (QTY: 2)

2.2.51. 4X24” BELT SANDER REPLACEMENT BELTS: 40 GRIT

2.2.52. 4X24” BELT SANDER REPLACEMENT BELTS: 80 GRIT

2.2.53. 4X24” BELT SANDER REPLACEMENT BELTS: 120 GRIT

2.2.54. 4X24” BELT SANDER REPLACEMENT BELTS: 180 GRIT

2.2.55. 4X24” BELT SANDER REPLACEMENT BELTS: 240 GRIT

2.2.56. PLASMA TORCH CONSUMABLE KIT (QTY: 10)

2.2.57. 2-1/8” BI-METAL HOLE SAW (QTY: 15)

2.2.58. REFRIGERANT EVACUATION PUMP: 7 CUBIC FT PER MINUTE (CFM)

DISPLACEMENT (QTY: 1)

2.2.59. MECHANICAL MANIFOLD GAUGE SET: 4 VALVES, 4 HOSES (QTY: 1)

2.2.60. UV-RESISTANT LINE SET TAPE (QTY: 15)

2.2.61. QUICK COUPLER: ¼” SAE MALE X 5/16 FEMALE (QTY: 45)

2.2.62. CABLE TIE: .19” WD (QTY: 500)

2.2.63. REFRIDGERANT HOSE GASKET (QTY: 50)

2.2.64. ECCENTRIC FLARING TOOL KIT (QTY: 1)

2.2.65. VACUUM GAUGE WITH DIGITAL LIQUID CRYSTAL DISPLAY (LCD)

(QTY: 1)

2.2.66. ADJUSTABLE ELECTRONIC TORQUE WRENCH (QTY: 1)

2.2.67. LEAK DETECTOR: 1 GALLON (GAL) (QTY: 3)

2.2.68. SCRUBBING PARTICLES, HAND CLEANER: 1 GAL (QTY: 1)

2.2.69. 100 PC ¾” CLAMP STAINLESS STEEL OR GALVANIZED HOSE CLAMPS

½-3/4” (QTY: 1)

2.2.70. ¾” INSIDE DIAMETER (ID) X 50 FT CLEAR VINYL TUBING, LOW

PRESSURE FLEXIBLE (QTY: 2)

3.0. DELIVERY REQUIREMENTS. All items shall be delivered to:

ATTN: 724 EABS CONS

PSC 65 BOX 1005

APO, AE 09909

Or to the consolidation point at Dover AFB, for which the contracting officer will supply shipping labels. Each packaged container shall be identified by its unit price, type of container, and dimensions (including height, length, width and weight).

4.0. STANDARD WARRANTY. The contractor shall provide any Original Equipment Manufacturer (OEM) standard commercial warranty applicable to the products being purchased at no additional cost to the Government.

4.1. Prior to project acceptance, the contractor shall provide the customer with all manufacturer warranties as needed for any component incorporated into this project such as equipment manuals, literature, CDs and DVDs and other documentation on all equipment.

4.2. Prior to project acceptance, the contractor shall provide written procedures, points of contact within company, and required information for all warranty services prior to project acceptance. This information shall include written confirmation of the warranty period, phone numbers and contact information/procedures for technical support, troubleshooting assistance, and replacement of faulty equipment.

5.0. GENERAL INFORMATION. Items must be brand new. Refurbished items are not authorized.

END OF STATEMENT OF REQUIREMENTS

Statement of Requirements

File details come from the government source that posted it. Updated .