CONSTRUCT DINING FACILITY

CADJ 19-0002

CHABELLEY AIRFIELD, DJIBOUTI

776TH EXPEDITIONARY AIRBASE SQ

HOST BASE COORDINATION/SIGNATURES

PROJECT/

CONTROL NUMBER

ASBESTOS CONTAINING MATERIAL(ACM)

& LEAD BASED PAINT(LBP) STATEMENT

ACM/LBP MATERIALS WILL BE LEFT IN PLACE FOR THIS PROJECT.

ACM/LBP MATERIALS WILL BE REMOVED UNDER THIS PROJECT.

NO SUSPECTED ACM/LBP WAS FOUND DURING VISUAL INSPECTIONS.

THIS PROJECT WILL NOT DISTURB ANY ACM/LBP MATERIALS.

BASE ENVIRONMENTAL

REVIEWED/SIGNED BY:

GENERAL NOTES:

1. ALL DIMENSIONS GIVEN FOR EXISTING CONSTRUCTION ARE TO BE

CONSIDERED APPROXIMATE AND SHALL BE FIELD VERIFIED.

2. VERIFIED DIMENSIONS SHALL APPEAR ON CONTRACTOR SHOP

DRAWINGS PRIOR TO BEING SUBMITTED FOR APPROVAL.

3. SHEET NOTES PERTAIN SPECIFICALLY TO THE SHEET THEY APPEAR ON

UNLESS NOTED OTHERWISE.

4. PATCH AND REPAIR ALL HOLES CREATED BY ABANDONED AND REMOVED

MECH. OR ELECT. PIPING, DUCTWORK AND/OR MATERIALS.

5. THE WORK SHALL PROVIDE A COMPLETE, FINISHED, OPERATING/

FUNCTIONING ASSEMBLY, OR APPARATUS READY FOR USE BY OTHER

CONTRACTORS TO WHICH CONNECTION OR USE IS REQUIRED, AND FOR

ACCEPTANCE BY GOVERNMENT.

6. EACH CONTRACTOR SHALL PROVIDE ALL NECESSARY INCIDENTALS AS

REQUIRED BY HIS WORK EVEN IF NOT SHOWN OR SPECIFICALLY

MENTIONED ON THE DRAWINGS OR IN THE SPECIFICATIONS,

INCLUDING SPECIFIC ITEMS REQUIRED BY CODE TO MAKE THE WORK

COMPLETE.

7. THE CONTRACTOR SHALL FAMILIARIZE HIMSELF WITH THE PROJECT

PRIOR TO BID. HE SHALL VISIT THE SITE, CHECK & VERIFY ALL

CONDITIONS. STUDY ALL SHEETS OF DRAWINGS AND READ THE

PROJECT STATEMENT OF WORK.

8. ANY SURFACE FINISHES DAMAGED BY DEMOLITION OR NEW

CONSTRUCTION SHALL BE REPAIRED TO MATCH PRIOR CONDITION

UNLESS NOTED OTHERWISE.

9. ALL MATERIALS, EQUIPMENT, DEVICES & INSTALLATION THEREOF

SHALL CONFORM WITH THE FOLLOWING CODES, STANDARDS,

REGULATIONS AND EDITIONS: INTERNATIONAL BUILDING CODE (IBC)

NATIONAL FIRE PROTECTION ASSOC. VOLS 1-16 (NFPA)

INTERNATIONAL PLUMBING CODE (IPC) UNDERWRITERS LABORATORY

10. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL PARTS OF HIS WORK

WHICH MAY BE SHOWN ON ANY SHEET OF THIS SET OR CONTAINED ON

ANY PAGE OF THE SPECIFICATIONS & SHALL EXECUTE ALL WORK IN

A PROFESSIONAL AND EXPEDIENT MANNER.

ANTI-TERRORISM OFFICE:

COMMUNICATIONS:

CHIEF OF PROJECT MANAGEMENT:

ENGINEERING FLIGHT CHIEF:

GROUND SAFETY:

CORROSION CONTROL:

FIRE DEPARTMENT:

CE OPERATIONS:

BASE CIVIL ENGINEER:

THIS FACILITY CONTAINS NO ACM/LBP MATERIAL.

PROJECT INSPECTOR:

PROJECT MANAGER:

AIRFIELD MANAGEMENT:

USING AGENCY:

CHECKED BY:

DRAFTER(S):

BIOENVIRONMENTAL ENGINEERING:

C O

N S

T R

U C

T M

U N

IT

IO

N S

S T

O R

A G

E A

R E

A

C H

A B

E L L E

Y A

IR

F

IE

L D

D

J

IB

O U

T I

T

H E

A B

S

C O V E R

P A G E

CADJ 19-0002

O C T

G-1 1 8

DRAWING INDEX:

DWG. NO. DESCRIPTION SHEET NO.

G-1 COVER PAGE 1

C-1 DINING FACILITY SITE LAYOUT - DEMO 2

C-2 DINING FACILITY SITE LAYOUT - NEW 3

A-1 FLOOR PLAN 4

A-2 EQUIPMENT LAYOUT 5

A-3 DETAILS 6

E-1 POWER PLAN 7

M-1 HVAC PLAN 8

*NOTE: FOR LARGER PROJECTS CREATE/USE ADDITIONAL SHEET*

BASE/VICINITY MAP

ECP

N

S

EW

Feet

13.5

Meters

5.42.70

PROJECT

LOCATION

DINING FACILITY SITE LAYOUT - DEMO

SCALE: 1:500

N

S

EW

GENERAL NOTES:

1. THE CONTRACTOR SHALL VERIFY THE EXACT

LOCATIONS OF ALL OF THE AREAS SHOWN DURING

THE DESIGN PHASE.

2. ALL DESIGNS SHALL BE SUBMITTED FOR REVIEW,

APPROVED/ACCEPTED BY THE PROJECT ENGINEER

PRIOR TO CONSTRUCTION.

PROJECT/

CONTROL NUMBER

SHEET OF

C O

N S

T R

U C

T D

IN

IN

G F

A C

IL

IT

Y C

H A

B E

L L E

Y A

IR

F

IE

L D

D

J

IB

O U

T I

T

H E

A B

S

D I N I N G

F A C I L I T Y

S I T E

L A Y O U T

D E M O

CADJ 19-0002

S S G T

W H A L E N

C-1 2 8

LEGEND

C O

N C

E P

T

BDOC

224A 224B

220A 220B

SDC

BDOC

BDOC

SDC

KEY NOTES:

EXISTING HESCOS TO BE REMOVED FOR DFAC

SITING, AND REPLACED ONCE CONSTRUCTION IS

COMPLETE.

EXISTING VEHICLE MAINTENANCE TENT TO BE

REMOVED AND RELOCATED BY THE GOVERNMENT.

EITHER WAY

P O W E R

P L A N T

R D

DEMO

EXISTING

DINING FACILITY SITE LAYOUT - NEW

SCALE: 1:500

N

S

EW

GENERAL NOTES:

1. THE CONTRACTOR WILL GRADE, AND LEVEL THE

CONSTRUCTION SITE PER THE STATEMENT OF

WORK.

2. CONTRACTOR WILL VERIFY THE ORIENTATION OF

THE FACILITY WITH THE GOVERNMENT

REPRESENTATIVE AND THE CONTRACTING

OFFICER.

PROJECT/

CONTROL NUMBER

SHEET OF

C O

N S

T R

U C

T D

IN

IN

G F

A C

IL

IT

Y C

H A

B E

L L E

Y A

IR

F

IE

L D

D

J

IB

O U

T I

T

H E

A B

S

D I N I N G

F A C I L I T Y

S I T E

L A Y O U T

N E W

CADJ 19-0002

S S G T

W H A L E N

C-2 3 8

C O

N C

E P

T

BDOC

224A 224B

220A 220B

SDC

BDOC

BDOC

SDC

KEY NOTES:

EXISTING REEFER CONEXES TO BE MOVED BY

THE GOVERNMENT AFTER CONSTRUCTION IS

COMPLETE.

EITHER WAY

P O W E R

P L A N T

R D

VEHICLE

FOOD DROP

OFF LOCATION

LEGEND

NEW

DINING FACILITY FLOOR PLAN - PROPOSED

SCALE: NTS

GENERAL NOTES:

1. THE CONTRACTOR WILL VERIFY THE ORIENTATION

OF THE FACILITY WITH THE GOVERNMENT

REPRESENTATIVE.

PROJECT/

CONTROL NUMBER

SHEET OF

C O

N S

T R

U C

T D

IN

IN

G F

A C

IL

IT

Y C

H A

B E

L L E

Y A

IR

F

IE

L D

D

J

IB

O U

T I

T

H E

A B

S

D I N I N G

F A C I L I T Y

S I T E

L A Y O U T

D E M O

CADJ 19-0002

S S G T

W H A L E N

A-1 3 8

ADDITIONAL

REFERENCES AS

REQUIRED

SHEET NUMBER

WHERE DETAIL,

SECTION OR

ELEVATION IS

TAKEN FROM

REFERENCE SYMBOL

DETAIL, SECTION

OR ELEVATION

REFERENCE

ADDITIONAL

REFERENCES AS

REQUIRED

SHEET NUMBER

WHERE DETAIL,

SECTION OR

ELEVATION IS

TAKEN FROM

SHEET NUMBER

WHERE DETAIL,

SECTION OR

ELEVATION IS

SHOWN

DETAIL, SECTION

OR ELEVATION

REFERENCE

NOTE: THIS SYMBOL ONLY APPLIES IF DETAILS,

SECTIONS ARE PLACED ON ANOTHER DRAWING SHEET

C O

N C

E P

T

100'

55'

15'

83'-5"

41'-1113

1 1

4 4

KEY NOTES:

30" WIDTH, STAINLESS STEEL COUNTERTOP

WALL WITH METAL ROLLING SHUTTER DOORS

MAIN DINING ROOM. TABLES, CHAIRS,

REFRIGERATORS, AND TRASH RECEPTACLES,

WILL BE PROVIDED BY THE GOVERNMENT.

EXTRA-WIDE DOORS WITH CYPHER LOCKS.

N

DINING FACILITY FLOOR PLAN - EQUIPMENT LAYOUT CONCEPT

GENERAL NOTES:

1. ALL EQUIPMENT TO INCLUDE: TABLES, CHAIRS,

FRIDGES,FOOD PREP EQUIPMENT, AND TRASH

RECEPTACLES WILL BE PROVIDED BY THE

GOVERNMENT.

PROJECT/

CONTROL NUMBER

SHEET OF

C O

N S

T R

U C

T D

IN

IN

G F

A C

IL

IT

Y C

H A

B E

L L E

Y A

IR

F

IE

L D

D

J

IB

O U

T I

T

H E

A B

S

E Q U I P M E N T

L A Y O U T

C O N C E P T

CADJ 19-0002

S S G T

W H A L E N

A-2 4 8

C O

N C

E P

T

100'

55'

N

5'

5'

5'-117

5'-3 3

MAIN DINING

FOOD PREP

ENTRANCE

EXIT

PROJECT/

CONTROL NUMBER

SHEET OF

C O

N S

T R

U C

T D

IN

IN

G F

A C

IL

IT

Y C

H A

B E

L L E

Y A

IR

F

IE

L D

D

J

IB

O U

T I

T

H E

A B

S

D E T A I L S

CADJ 19-0002

S S G T

W H A L E N

A-2 6 8

GENERAL NOTES:

1.ALL MEASUREMENTS ARE APPROXIMATE.

2. CONTRACTOR WILL PROVIDE THE PRE-ENGINEERD BUILDING,

AND RELATED EQUIPMENT.

C O

N C

E P

T

42'

3'

5'

OVERALL GUIDE WIDTH

FINISHED FLOOR

SLIDE LOCKHANDLE

CLEAR OPENING WIDTH

OVERALL FRAME WIDTH

SHAFT EXTENSION

CHARGE WHEEL

SERVING LINE WALL

SHEET OF

C O

N S

T R

U C

T D

IN

IN

G F

A C

IL

IT

Y C

H A

B E

L L E

Y A

IR

F

IE

L D

D

J

IB

O U

T I

T

H E

A B

S

P O W E R

P L A N

CADJ 19-0002

S S G T

W H A L E N

E-1 7 8

GENERAL NOTES:

1. CONTRACTOR WILL VERIFY THE PLACEMENT OF ALL

ELECTRICAL COMPONENTS WITH THE GOVERNMENT

REPRESENTATIVE, AND CONTRACTING OFFICER.

2. INSTALL TWO ELECTRICAL PANELS, ONE IN THE FOOD

PREP AREA, AND ONE IN THE MAIN DINING AREA.

3. GOVERNMENT WILL DO MAIN POWER HOOK-UP FROM

FACILITY MAIN ELECTRICAL PANEL TO SDC.

C O

N C

E P

T

POWER PLAN

SCALE: NTS

GFI

G F I

G F I

G F I

G F I

G F I

G F I

G F I

G F I

G F I

LEGEND

SINGLE DUPLEX OUTLET

ELECTRICAL PANEL

KEY NOTES:

OUTLETS IN THE FOOD PREP AREA WILL BE

INSTALLED ABOVE THE COUNTERTOP, AND WILL

BE DOUBLE DUPLEX.

1 1

DOUBLE DUPLEX OUTLET

N

PP1

P P

SHEET OF

C O

N S

T R

U C

T D

IN

IN

G F

A C

IL

IT

Y C

H A

B E

L L E

Y A

IR

F

IE

L D

D

J

IB

O U

T I

T

H E

A B

S

H V A C

P L A N

CADJ 19-0002

S S G T

W H A L E N

M-1 8 8

GENERAL NOTES:

1. CONTRACTOR WILL VERIFY THE PLACEMENT OF ALL

HVAC COMPONENTS WITH THE GOVERNMENT

REPRESENTATIVE, AND CONTRACTING OFFICER.

C O

N C

E P

T

HVAC PLAN

SCALE: NTS

LEGEND

MAIN ELECTRICAL PANEL

2 TON SPLIT HVAC UNIT

PP1

P P

N

File details come from the government source that posted it. Updated .