FA5270-14-Q-A047 Washers, Dryers, Stoves Questions and Answers

Question 1: By 120/240 v; 60 Hz – do you mean it needs to be dual performance for 220v and 110v built or we can add a separate device like Step-up/Down Transformer to take care of the job?

Government Response to Question 1: No, Washers have to be 120 volts 60 Hertz, dryers and stoves have to be 220 volts 60 hertz nothing is dual voltage

Question 2: Stoves one point in the specification is strange even Whirlpool assistance told.

Theses items are only available in 110volts 60hz. They are not available in 110/220volts 60hz, nor are they available 220volts 50hz.

Government Response to Question 2: The washers are 110 volts 60hz and the dryers and stoves 220 volts 60hz