This document is a Salient Characteristics specification for a Mobile Inflatable Paint Booth for the 36th Maintenance Squadron at Andersen Air Force Base in Guam. The requirement is for a portable paint booth with specific technical and operational specifications, including interior dimensions of 40' × 23' × 12', flame-retardant PVC structure, pressurized airlock entry system, and a comprehensive filtration system meeting EPA and NESHAP standards. The booth must have four 120V blower fans, explosion-proof lighting, an electric air compressor, and demonstrate 99.87% emissions capture efficiency.

The solicitation offers two shipping options: Option A with delivery 120 days after receipt of order to Andersen AFB in Guam, and Option B with delivery 45 days after receipt of order to a DLA Consolidation Point in Tracy, California. The paint booth must operate on standard 120V power, include windows for external visibility, meet OSHA confined space standards, and comes with a standard 1-year warranty. The solicitation is identified by the number FA524025QM162 and is specifically for on-site repair of aircraft parts and Aerospace Ground Equipment.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FA524025QM162 - 36 MXS Mobile Inflatable Paint Booth

Salient Characteristics

36 MXS Mobile Inflatable Paint Booth, Andersen AFB, Guam

REQUIREMENT DESCRIPTION WITH SALIENT CHARACTERISTICS

1. Quantity & General Requirements

• A minimum of one (1) Portable Paint Booth is required.

• Must be suitable for on-site repair of aircraft parts and Aerospace Ground Equipment

(AGE).

2. Dimensions & Structure

• Interior dimensions must be 40 feet (L) × 23 feet (W) × 12 feet (H).

• Must be free-standing and not require continuous inflation to maintain structure.

• Must include tie-downs and floor anchors for securing the booth in outdoor environments.

• Booth structure must be made of flame-retardant, antistatic PVC with glass-clear panels for visibility.

• Structural base material must be heavy-duty PVC-coated polyester.

• All closures must be splash-proof 8mm coil-type zippers or equivalent.

• All panels, doors, zippers, windows, floor sections, and filters must be installed using similar fastener components and be replaceable.

3. Access & Safety Features

• Must include a fully removable door for unobstructed access.

• Must include a personnel door with replaceable zippers.

• Must feature emergency exit pull handles on interior side windows located on both sides.

• Must include a pressurized airlock entry system to prevent contamination during ingress/egress.

• Must meet all applicable OSHA standards for confined spaces.

4. Ventilation & Airflow

• Must include a minimum of four (4) 120V blower fans, each capable of delivering airflow between 800–2800 CFM.

• Fans must be multi-speed, rated at 1 HP, and compatible with 120V/230V and 50Hz operation.

• Must provide complete air changes every 3 minutes to maintain a clean working environment.

• Must utilize High Volume Low Pressure (HVLP) airflow to minimize overspray and improve capture efficiency.

5. Filtration System

• Must meet EPA and NESHAP standards for air filtration and all relevant aerospace safety/environmental regulations.

• Must include:

o Replaceable pre-stage filters on the inlet side wall.

o A three-stage exhaust filtration system, with the final stage being a charcoal bed filter.

o Activated carbon filters using Carbotec RT20 foam or equivalent for VOC and odor control.

• Filter surface area must include:

o Input filters: Minimum 3.85 m² using G4 synthetic media.

o Exhaust filters: Minimum 10.77 m² of synthetic paint arrestor media.

o Carbon filters: Minimum 2.39 m².

6. Lighting & Visibility

• Must include windows that allow external visibility of painting operations.

• Lighting system must be explosion-proof, with sufficient brightness to meet 1000 lux at working height.

7. Inflation & Compressor System

• Must include an electric air compressor pump with a built-in monitor to auto-adapt pressure and manage inflation/deflation.

• Booth must inflate/deflate in under 10 minutes and be operationally ready within 1 hour.

• Must not rapidly deflate or lose pressure once inflated.

8. Power Requirements

• All powered components must operate on standard 120V electrical power.

9. Environmental & Safety Compliance

• Must demonstrate 99.87% capture efficiency for emissions.

• Must visibly demonstrate compliance with EPA, OSHA, and NESHAP standards for mobile aerospace painting operations.

10. Warranty

• Standard 1 year warranty.

11. Delivery – Offeror has the option to ship to one of the following addresses (see Shipping Options A and B for more information)

SHIPPING OPTION A:

Delivery Date: 120 Days After Receipt of Order (ARO)

• The Portable Paint Booth must be shipped via Direct Delivery Method (FOB

Destination) to the following address on Andersen Air Force Base (AFB), Guam:

o 36 MXS/MXMFS, Unit 14012, Bldg 18006 Andersen Air Force Base Yigo, Guam 96929

APO Address:

36 MXG

Unit 14012

APO AP 96543-4012

SHIPPING OPTION B:

Delivery Date: 45 Days After Receipt of Order (ARO)

• The Portable Paint Booth must be shipped via Direct Delivery Method (FOB

Destination) to the DLA Consolidation Point at the following address in Tracy, California:

o DDJC Consol and Contain Pt Whse 30

Warehouse Clerk Ph 209 839 5028 25600 S Chrisman Rd CCP Whse 30 Tracy, CA 95304-5000