This Statement of Work (SOW) details requirements for a 4-channel programmable bi-directional RF over Fiber (RFoF) link system for Yokota Air Base. The system must support radio connections within a 3 MHz to 1.215 GHz frequency range and be delivered within 3-4 months of contract award. Key technical specifications include 8-channel CWDM optical aggregation, 20W maximum RF input power, -82 ± 3 dB nominal link gain, and compatibility with 110/220 VAC power supplies.
The contractor must provide comprehensive documentation including assembly instructions, warranty details, user manuals, and integration guidelines. Additional requirements include remote management via TCP/IP, independently configurable RF channels, and compliance with safety standards like EN60950-1:2006 and FCC CFR-47 Part 15 Subpart B. The deliverables will include the fully operational RFoF link system, complete documentation package, warranty information, and verification of compliance through test reports. A standard one-year warranty covering parts and labor with remote support within 72 hours is also specified.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| RFoF Solicitation.pdf | ||
| Questions and Answers Yokota Air Base.pdf | ||
| Provisions and Clauses.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
STATEMENT OF WORK
RF OVER FIBER (RFoF) LINK SYSTEM FOR YOKOTA AIR BASE
1.0 DESCRIPTION OF SERVICES
The contractor shall provide a 4-channel programmable bi-directional RF over Fiber (RFoF) link system meeting specific operational requirements for Yokota Air Base, supporting radio connection needs within a frequency range of 3 MHz to 1.215 GHz.
2.0 SCOPE OF WORK
The contractor shall procure and deliver the RFoF link system to Yokota Air Base within 3-4 months from contract award, following an agreed-upon delivery schedule.
The contractor must deliver comprehensive documentation, including:
- Assembly instructions
- Manufacturer’s warranty details
- User manuals
- Integration guidelines
The contractor shall provide a standard one-year warranty covering parts and labor.
Support shall be available via remote assistance within 72 hours of notification by the government.
3.0 RF OVER FIBER LINK SYSTEM SPECIFICATIONS
- Frequency Range: 3 MHz – 1.215 GHz (fully programmable, bi-directional)
- Number of Channels: 4 (bi-directional)
- Optical Aggregation: 8-channel CWDM (Single Mode Fiber)
- RF Input Power: 20W maximum (includes 30 dB attenuators)
- Nominal Link Gain: -82 ± 3 dB (adjustable)
- Gain Flatness: ±1.2 dB
- Input Compression Point: +46 dBm (with Tx attenuation at 10 dB)
- Spurious: ≤ -80 dBm
- VSWR (max): 1.5:1
- Input/Output Impedance: 50 Ohms
- Optical Connectors: LC/APC
- RF Connectors: N-Type
- Data Connector: RJ-45
- Power Supply: 110/220 VAC, 50/60 Hz
- Enclosure Dimensions: Standard 19” 1U (445 mm W x 480 mm L x 44 mm H per enclosure)
- Operating Temperature: -20°C to +60°C
- Storage Temperature: -40°C to +85°C
4.0 ADDITIONAL REQUIREMENTS
- Management and Control: Remote management via TCP/IP (HTML, REST, SNMP interfaces)
- System Configuration: Independently configurable bi-directional RF channels with built-in step attenuators
- Safety & Compliance: EN60950-1:2006(2nd), EMC ETSI EN 300 386 v1.6.1 (2012-04), FCC CFR-47 Part 15 Subpart B
5.0 DELIVERABLES
- Fully operational RFoF link system meeting specified requirements
- Complete documentation package (manuals, assembly instructions, integration guidance)
- Warranty information
- Verification of compliance via documented test reports
| RF OVER FIBER (RFoF) LINK SYSTEM FOR YOKOTA AIR BASE |
| 1.0 DESCRIPTION OF SERVICES |
| 2.0 SCOPE OF WORK |
| 3.0 RF OVER FIBER LINK SYSTEM SPECIFICATIONS |
| 4.0 ADDITIONAL REQUIREMENTS |
| 5.0 DELIVERABLES |
File details come from the government source that posted it. Updated .