This Request for Information from the 35th Contracting Squadron at Misawa Air Base in Japan seeks vendor capabilities to provide a trailer-mounted Reverse Osmosis Water Purification Unit. The ROWPU trailer must be capable of removing at least 95% of PFOS, PFHxS, and PFOA substances from water intake with a stainless steel filter life of over 5 years. Preferred dimensions are a height of 6'10", width of 8', and length of 10'. The trailer should include a built-in diesel generator with commercial power connection, produce 530 gallons per hour of purified water, and include a minimum of 6 months of chemicals. It must have an external fuel connection and wireless monitoring capabilities to allow for remote control and automatic shutoff. Vendors able to meet these specifications or provide alternative solutions should contact the identified points of contact by email.

View the file

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DEPARTMENT OF THE AIR FORCE

35TH FIGHTER WING (PACAF)

MISAWA AIR BASE, JAPAN

12 Mar 24

REQUEST FOR INFORMATION

The 35th Contracting Squadron is seeking information regarding Reverse Osmosis Water Purification Unit (ROWPU) trailers. Any vendors that are capable of providing a ROWPU trailer with the following requirements are encouraged to contact the points of contact (POCs) in this request for information (RFI).

The ROWPU trailer must be capable of meeting the following:

1. 95%-99% PFOS, PFHxS, and PFOA substance removal from water intake.

2. Stainless Stell filters requiring a maximum of backwash for upkeep, must have an effective life of 5 years or more.

3. Trailer mounted for towing.

4. Preferred dimensions of H: 6’10”, W: 8’, L: 10’

5. Shall include a built in generator using diesel fuel, in addition to having commercial power connection capabilities.

6. 530 GPH flow rate.

7. A minimum 6 months of chemicals would be required to be included.

8. External fuel connection for the generator in item 5 that allows for refueling.

9. Wireless transmitter capabilities that can be used with a SCADA system. Shall allow for remote monitoring and control, along with an automatic shut off in case of system failure.

If your company is capable of providing the above, or if the specifications above are unfeasible, please reach out to SSgt Elijah Braly, elijah.braly@us.af.mil , and SrA Aiyana Scott, aiyana.scott.2@us.af.mil. This is not a solicitation and interested parties shall not operate under the assumption that this RFI will lead to a solicitation.