Statement of Work For Structure Replacement for 354th Aircraft Maintenance Squadron

1. Structure must be 40 feet long, 20 feet wide. Height must not exceed 14 feet, but must be a minimum of 12 feet.

2. Structure shape roof may be domed or gable.

3. Structure must have a garage style door at one end. Door must be at least 8 feet wide and at least 10 feet tall. Door must be able to be secured with an external padlock. No other doors are necessary.

4. Structure must withstand typical snow loads, 40 pounds per square foot, encountered at Eielson AFB.

5. Structure material must withstand typical temperature extremes, -60*F to 90*F, encountered at Eielson AFB.

6. Structure will require a method to secure it to the asphalt. Securing device must be able to be adjusted over time to account for expansion and contraction of the structure.

7. Structure must not be permanent. Structure will have to be move in the future.

8. Structure does not require insulation.

9. Structure does not require electrical power.