This document is an attachment titled "Salient Characteristics - ACE ISU" that provides detailed requirements for a customized expandable ISU-style workshop. The key details are:
The Air Force requires a rapidly deployable, all-weather shelter system with a 463L pallet footprint to support sensitive equipment in austere environments. The design must include an expandable side wall with a minimum of 120 sq. ft. of working space, double entry personnel doors, canvas end walls, extensive tie-down points, storage cabinets and workbenches, electrical power and lighting, and an integrated HVAC system. The workshop must meet all applicable ATTLA certifications. This requirement is part of Solicitation FA500024Q0073 issued by the Department of the Air Force Pacific Air Forces for the purchase and delivery of this customized ISU workshop to Joint Base Elmendorf-Richardson in Alaska.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| FA500024Q0073 - Attachment 1 - Salient Characteristics - ACE ISU_Redacted AMEND 01.pdf | ||
| FA500024Q0073 - ACE ISU Combo AMEND 01.pdf | ||
| FA500024Q0073 - Attachment 2 - Pricing Schedule - ACE ISU.pdf | ||
| FA500024Q0073 - ACE ISU Combo.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DEPARTMENT OF THE AIR FORCE
3rd WING (PACAF)
JOINT BASE ELMENDORF-RICHARDSON, ALASKA
20 Aug 24
MEMORANDUM FOR 673 CONS
1. 3 MUNS Futures requires rapidly deployable, all weather shelter systems for working with sensitive equipment in austere environments. Weather conditions at ACE locations are unknown, and these structures will provide a covered space for sensitive test equipment, an area that maintenance can be performed even during inclement weather, as well as secure, rapid, ready to operate cargo space.
2. The following are characteristics required in the design:
a. ISU platform with a single 463L pallet footprint of 88”w x 108”l x 102”h in shipping configuration.
b. Maximum weight with all requirements of 6000 lbs. Minimum load rating of 10000 lbs.
total weight with loaded equipment.
c. One expandable side wall using the hard surface as a floor with pop out canvas walls, with a solid wall opposite. Minimum of 120 sq. ft. of working space when expanded.
d. Double entry personnel doors.
e. Canvas end wall with zip open and rollable side walls.
f. 25-40 recessed tie down points integrated into the floor for securing cargo during shipping.
g. 25-40 recessed tie down points integrated into the ceiling and ceiling perimeter for securing cargo during shipping.
h. Setup and stowage instruction placards.
i. Removable awning over double doors.
j. Protective metal curtain to protect canvas when in shipping configuration.
k. ISU will meet all ATTLA certifications from manufacturer. Manufacturer will provide all necessary analysis and reports to the user to be submitted to ATTLA for approval.
l. Two (2) each approximately 40”h x 18”d x 36”w shelves on solid end wall.
m. One (1) each approximately 40”h x 18”d x 30”w cabinet with two (2) shelves on solid end wall.
n. One (1) each approximately 40”h x 18”d x 30”w 7 drawer tool box and one (1) each approximately 40”h x 18”d x 24”w 7 drawer tool box along back wall.
o. Metal tabletops with integrated grounding on cabinets and workbenches installed IAW AFMAN 32-165 para 11.1, 11.1.1, & 11.1.2.
p. Minimum 39” wall mounted LED TV with protective cover for shipping
q. LED ceiling lighting.
r. Integrated 40A 120/240V 60Hz single phase electrical system to power LED lighting, AC unit, TV/computer monitors, and computer/tablets with a minimum of 8 receptacles, spaced throughout the working space.
s. Wrist strap grounding wire across front of grounded work surfaces installed IAW AFMAN 32-165 para 11.1, 11.1.1, & 11.1.2.
t. Static bus bar installed IAW AFMAN 32-165 para 11.2
u. Integrated connection points for external power from MEP generator, and two (2) minimum 4”x4” closable ports with rubber bungs to route communication system wiring and grounding cables separate from each other.
v. 8k BTU slide-in/slide out AC unit.
CUI