PowerCables_ClarifyingQuestions.pdf
PDF 63 KB Posted
- Attached to
- High Amp Extension Power Cables - Amend 1 Federal contract opportunity
- Solicitation number
- FA500023Q0113
About this file
This document contains clarifying questions and answers regarding a federal solicitation for high amp extension power cables. The solicitation seeks color-coded Type K EPDM jacketed cables rated to 600V and -40C for use in an arctic environment. While black cables may be offered, the preference is for entire cables to be color coded for ease of routing. A 50-foot, 125/250V extension cord with 100 amp connectors is also required. The related solicitation was issued by the Department of the Air Force Pacific Air Forces for high amp extension power cables and is identified as solicitation number FA500023Q0113.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Salient Characteristics_PowerCables.pdf | ||
| Power_Cables_Combo.pdf | ||
| Attachment 1 - Pricing Schedule_PowerCables.docx | DOCX document |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1. Is there a specified AMP rating for the Type K 4/0 Cable 400 AMPS?
a. Answer: I’m not sure about amperage but we require cables to be rated to 600V.
2. Type K EPDM Jacketed Cables are rated to -40 C. Given the arctic environment, is the end user requesting cables that are rated -60C ?
a. Answer: -40C would be adequate.
3. The salient characteristics state the cables are to be color coded. Given the cam locks are color coded can the end user offer black cable or is the end user requesting solid colors for each phase, neutral, ground cable?
a. Answer: We would prefer the entire cable to be color coded. This would ease routing in a rats nest configuration which will inevitably happen. If unable that’s okay too.
4. What are the connector specifications for the 50 amp extension cord?
a. Answer: 100ft length, 125/250 V