EMERGENCY LQM

Catalog Number

Notes

Type

ORDERING INFORMATION

Example: LQM S W 3 R 120/277 EL N Example: LQM S W 3 R MVOLT EL N SD

Example: LQM S W 3 R MVOLT EL N SD CLSR

LQM

Family Face type Housing color Number of faces Letter color Input voltage Operation Options

LQM 1 S Stencil (blank) Black W White

3 Single face with extra faceplate and color panel

R Red G Green

120/277 Dual voltage MVOLT Multi volt 120-277, 50/60hz 2

(blank) AC only X2 Primary and secondary

AC inputs provided 3

EL N Nickel cadmium battery

(blank) None NOM NOM certified for Mexico 4

SD Self-diagnostics 5

CLSR Connected Life Safety Radio 6

7-5/8 (19.3)

11-3/4 (29.8)

(5.1)

All dimensions are inches (centimeters) unless otherwise specified.

Specifications

Length: 11-3/4 (29.8)

Depth: 2 (5.1)

Height: 7-5/8 (19.3)

Weight: 2.6 lbs (1.2 kgs)

Accessories: Order as separate item.

ELA WG1 Back-mount wireguard 7 ELA WGEXE End-mount wireguard 7

ELA WGEXT Top-mount wireguard 7 ELA LQMUS12 12" stem kit 8

FEATURES & SPECIFICATIONS

INTENDED USE — Ideal for applications requiring attractive, quick-installation exit signs and low energy consumption. Certain airborne contaminants can diminish the integrity of acrylic and/ or polycarbonate. Click here for Acrylic-Polycarbonate Compatibility table for suitable uses.

CONSTRUCTION — Engineering-grade thermoplastic housing is impact-resistant, scratch-resistant, and corro-sion-proof. UL94V-0 flame rating. UV-stable resin resists discoloration from natural and man-made light sources.

Rugged unibody housing snaps together with no additional mechanical fasteners. Faceplate and back cover are inter-changeable on housing. Positive snap-fit tabs hold faceplate securely, yet easily removable for lamp compartment access.

Universal directional Chevron inserts are easily removed and reinserted. Uniform illumination without shadows or hot spots. Reinforced, impact-resistant color panels. Letters 6” high with 3/4” stroke, with 100

ft. viewing distance rating, based upon UL924 standards.

U.S. Patent No. 5,526,251; 5,611,163; 5,739,639; 5,954,423; 5,988,825; 6,152,581; D383,501 ;

D495,751 and 6,502,044. Other patents pending.

OPTICS — LEDs mounted on printed circuit boards. Low energy consumption – less than one watt. LED lamp operates in normal (AC input) and emergency (DC input) modes.

The typical life of the exit LED lamp is 10 years.

ELECTRICAL — Dual voltage input capability (120/277V) and 120V through 277V for MVOLT with SD.

Low-voltage disconnect prevents excessively deep discharge that can permanently damage battery. Conve-niently located test switch and LED provide visual and manual means of monitoring system.

Constant-current series charger minimizes energy consumption and provides low operating costs. Printed circuit boards are 100% quality tested during manufacturing. Current-limiting charger circuitry protects printed circuit boards from shorts.

AC/LV reset (line latch) allows battery connection before AC power is applied and aids in preventing battery damage from deep discharge.

Crystal oscillator timing system with watchdog protection for precision accuracy.

Brownout protection is automatically switched to emergency mode when supply voltage drops below 80% of nominal.

Battery: Sealed, maintenance-free nickel-cadmium battery delivers 90-minutes capacity to emergency lamps.

Two-state constant-current charge maximizes battery life and automatically recharges after battery discharge.

Diagnostics: Single-point microcomputer control for all electronic features.

Single multi-chromatic LED indicator to display two-state charging, test activation and three-state diag-nostic status.

Test switch provides manual activation of 30-second diagnostic testing for on-demand visual inspection.

Self-diagnostic testing for five minutes every 30 days and 90 minutes every six months.

Diagnostic evaluation of LED light source, AC to DC transfer, charging and battery condition. Continuously monitors AC functionality.

CLSR option: Connected Life Safety radio transmits monthly and annual test results and diagnostics informa-tion for automated reporting requirements.

INSTALLATION — Universal (top-, end-, or back-) mounting. Easily removed mounting knockouts. J-box pattern on back panel. Housing snaps to canopy with four positive-locking tabs. Cam-locking pin tightly secures housing to canopy.

Ships standard with additional face plate.

LISTINGS — UL damp location listed 50°-104°F (10°-40°C) standard. NOM Certified (see options). Meets UL924, NFPA 101 (current Life Safety Code), NEC and OSHA illumination standards. Meets all applicable FCC Title 47, Part 15, Subpart B requirements.

Thermoplastic Exits

LQM

LED LAMPS

For shortest lead times, configure product using bolded options.

WARRANTY — 5-year limited warranty. (Battery is prorated.) Complete warranty terms located at:

www.acuitybrands.com/support/customer-support/terms-and-conditions Note: Actual performance may differ as a result of end-user environment and application.

All values are design or typical values, measured under laboratory conditions at 25 °C.

Specifications subject to change without notice.

† Exit Signs Certified in the CA Title 20 Appliance Efficiency Database.

Looking for Contractor Select readily available configurations? Click here to visit Contractor Select™ spec sheet or go to www.contractorselect.com

Notes 1 LQM available with Custom Signage. See spec sheet, Custom-Signage.

2 Only available with EL N SD. See Example for ordering.

3 Not available with other options. Both circuits can be energized at the same time.

4 Available with stencil face and white housing only. Not available with MVOLT EL N SD configuration.

5 Only available with MVOLT and EL N operation. See Example for ordering.

6 Only available with MVOLT EL N SD. Connected Life Safety radio transmits monthly and annual test results and diagnostics information for automated reporting requirements.

7 See spec sheet ELA-WG.

8 See spec sheet ELA-Stemkits.

https://pdmassets.azureedge.net/library/ll/documents/specsheets/acrylic-polycarbonate-compatibility.pdf http://www.acuitybrands.com/support/customer-support/terms-and-conditions https://www.acuitybrands.com/products/detail/999297/lithonia-lighting/contractor-select-lqm/quantumr-led-exit-sign https://www.acuitybrands.com/products/detail/47579/lithonia-lighting/lqm/quantumr-led-exit-sign https://www.acuitybrands.com/products/detail/47579/lithonia-lighting/lqm/quantumr-led-exit-sign https://www.acuitybrands.com/products/detail/47579/lithonia-lighting/lqm/quantumr-led-exit-sign

LQM

EMERGENCY: One Lithonia Way Conyers, GA 30012 Phone: 1-800-705-SERV (7378) techsupport-emergency@acuitybrands.com www.lithonia.com © 1993-2020 Acuity Brands Lighting, Inc. All rights reserved. Rev. 12/01/20

LQM LED, Quantum®

MOUNTING

All dimensions are inches (centimeters) unless otherwise specified.

Shipping weight: 2.6 lbs. (1.2 kgs.)

SPECIFICATIONS

5-5/8 (14.7)

7-5/8 (19.3)

7-5/8 (19.3)

3-7/8 (9.6)

8-3/8 (21.3)

11-3/4 (29.8)

11-3/4 (29.8)

5-7/8 (14.9)

4-1/2 (11.4)

(5.1)

Top Mounting

End Mounting

Back Mounting

ELECTRICAL

Primary Circuit

Type1 Typical LED life2

Supply voltage

Input watts

Max.

amps

Red LED AC Only 10 years 120 .62 .05 277 .69 .06

Green LED AC Only 10 years 120 .62 .05 277 .74 .06

Red LED Emergency 10 years 120 .71 .05 277 .92 .06

Green LED Emergency 10 years 120 .66 .05 277 .70 .06

BATTERY

Nickel Cadmium

Voltage Typical shelf life3 Typical life3 Maintenance4 Temperature range5

1.2 3 years 7-9 years none 50°F - 104°F (10°C - 40°C)

Notes 1 LED lamps operate in normal (AC input) and emergency (DC input) modes.

2 Based on continuous operation. The typical life of the exit LED lamp is 10 years.

3 At 77°F (25°C).

4 All life safety equipment, including emergency lighting for path of egress must be maintained, serviced and tested in accordance with all National Fire Protection Association (NFPA) and local codes. Failure to perform the required maintenance, service, or testing could jeopardize the safety of occupants and will void all warranties.

5 Optimum ambient temperature range where unit will provide capacity for 90 minutes. Higher and lower tempera-tures affect life and capacity.

http://www.lithonia.com

Text Field 1:
Text Field 2:
Text Field 3:
Text Field 4: S
Text Field 5: W
Text Field 6: 3
Text Field 7: G
Text Field 8: 120/277
Text Field 9: EL N
Text Field 10:
Text Field 11: