SPECS for Stock Picker.pdf

PDF 141 KB Posted

Attached to
LRS Material Handling Equipment
Solicitation number
FA489726Q0016
Issued by

About this file

This is a specification sheet for Material Handling Equipment issued by the 366th Logistics Readiness Squadron at Mountain Home Air Force Base, Idaho, dated 5 February 2026.

The requirement is for one stock picker unit for warehouse operations. The equipment must meet detailed minimum specifications across physical characteristics, including a UL Type EE/E rated unit with 24-volt battery power, TT mast type, 240-inch lift height, and standard straddle configuration. Key physical specifications include collapsed height of 107 inches, extended height of 334 inches, programmable lift/lower cutout, standard lead acid battery power source, and 2"x4" solid forks with 36-inch length and adjustable 24-30 inch spread. Additional required features include an 84-inch operator compartment height, steel slat overhead guard, key switch control, fixed height power unit facing with adjustable 7-inch color capacitive touchscreen display, ergo floor mat, full body harness with retractable tether, wire mesh visibility windows, rail guidance system with standard profile guide wheels, and integrated InfoLink hardware. The equipment must include a one-year/unlimited hours warranty. Shipping must be included in all quotations, with delivery required to Building 1132, 270 Aardvark Avenue, Mountain Home AFB, Idaho 83648, no later than 30 days after contract award. No installation or training is required as this constitutes an upgrade from previously procured equipment.

View the file

Other files

File Type Posted
SPECS for Work Assist Vehicle.pdf PDF
Solicitation - FA489726Q0016.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SPECIFICATION SHEET

Mountain Home AFB, ID

Material Handling Equipment (MHE) 366 LRS 5 Feb 2026

1. GENERAL: The 366th Logistics Readiness Squadron located at Mountain Home AFB, ID requires 1 Stock Picker for the Warehouse.

2. MHE MINIMUM SPECIFICATIONS: The Material Handling Equipment must (at a minimum) comply with the following salient characteristics:

2.1. Physical Characteristics

2.1.1 UL Type EE Rated UL E Rated (Standard)

2.1.2 Battery Voltage 24

2.1.3 Mast Type TT

2.1.4 Straddle Standard

2.1.5 Lift Height 240"/6095mm

2.1.6 Collapsed Height 107"/2720mm

2.1.7 Extended Height 334"/8485mm

2.1.8 Lift/Lower Cutout Programmable Lift/Lower Cutout

2.1.9 Hydraulic Performance Package Standard Lower with Regenerative Lowering

2.1.10 Lift Speed Standard

2.1.11 Power Source Type Standard Lead Acid Battery

2.1.12 Platform Step Height STD 8.10"/205mm Step Platform

2.1.13 Environmental Package Standard Environmental Package

2.1.14 Cold Conditioning Oil 100% Standard Hydraulic Oil

2.1.15 Operator Compartment Depth 27"/685mm

2.1.16 Operator Compartment Height 84"/2135mm

2.1.17 Operator Compartment Width 48"/1220mm

2.1.18 Overhead Guard Options Steel Slats

2.1.19 Keyless On/Off Switch Key Switch

2.1.20 Fork Type 2"x4"/50mm x 100mm Solid Forks

2.1.21 Fork Length 36"/915mm

2.1.22 Adjustable Fork Spread 24" - 30"/610mm - 762mm

2.1.23 Outrigger Outside Dimension 42"/1065mm

2.1.24 Battery Compartment B Compartment

2.1.25 Battery Spacer / Max. Batt Size B58 14.06" x 36.25" x 31" / 357mm x 921mm x

787mm

2.1.26 Battery Connector Type SB350

2.1.27 Battery Connector Color Red

2.1.28 Operator Controls Fixed Height Power Unit Facing

2.1.29 Display Options Adjustable RAM Mounted 7"/178mm Color

Capacitive Touchscreen Display

2.1.30 Display Location Right Side - Power Unit Facing

2.1.31 Floor Mat Ergo Mat

2.1.32 Pallet Grab Manual - 1.5"/40mm Wide Stringer

2.1.33 Body Harness Full Body Harness L/XL

2.1.34 Tether Retractable Tether

2.1.35 Tether Location Alternative Tether Attachment Locations

2.1.36 Upper Visibility Window Wire Mesh Screen

2.1.37 Middle Visibility Window Wire Mesh

2.1.38 Center Floor Visibility Window Yes

2.1.39 Side Floor Slot Visibility Windows Yes

2.1.40 InfoLink® Ready System Integrated InfoLink Hardware

2.1.41 Guidance System Rail Guidance

2.1.42 Guide Wheel Profile Standard Profile Guide Wheels

2.2. Warranty

2.2.1. Standard: One year/Unlimited Hours

3. INSTALLATION: No installation needed.

4. TRAINING: No training is needed these are just upgrades from previous years.

5. SPECIFICS:

3.1. Shipping must be included in the quotation.

3.1.1. Contractor shall deliver to Bldg. 1132 – 270 Aardvark Ave Bldg 1132, Mountain Home AFB ID, 83648

3.1.2. Delivery will be no later than 30 days after date of contract (ADC).

File details come from the government source that posted it. Updated .