Key requirements include: 36 feet of crash-rated, modular portable barrier system with pivot capability and storage case; minimum 7.5-ton truck at 30 mph impact protection; ability to connect barriers for continuous coverage; option to pivot into an operational gate; safety yellow color for visibility; easy assembly with no tools required; and an open structure design to avoid active shooter cover. Delivery is required within 60 days of contract award to the Main Gate at Mountain Home AFB, ID. Shipping is to be included in the quotation.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SPECIFICATION SHEET

Mountain Home AFB, ID

Modular Barriers 8/26/2024

AMENDMENT 1

1. GENERAL: The 366th Security Forces Squadron located on Mountain Home AFB, ID requires a portable barrier system to be used for special events.

1.1. Certification: IAW DoDI o-2000.16/V1-DAFI 31-145-0/Antiterrorism (AT) Program Implementation anti-vehicle barriers must be designed to comply with UFC 4-022-02, Selection and Application of Vehicle Barriers. IAW UFC 4-022-02/Selection and Application of Vehicle Barriers, only barriers on either the DoS list or DoD list are approved for use on DoD projects.

Therefore, the portable barriers must be on the current DoD Anti-Ram Barrier List (attached).

2. PORTABLE BARRIERS SPECIFICATIONS: The Barriers must (at a minimum) comply with the following salient characteristics.

2.1. 36 feet of Crash rated portable barrier system with barrier pivot system and storage case.

2.2. Physical Characteristics:

2.1.1. Must provide a minimum of protection from a 7.5-ton truck at 30 MPH.

2.1.2. Barrier system must be modular and adaptable to any road width.

2.1.3. Multiple traffic lanes of continuous coverage must be able to be assembled without the use of cables.

2.1.4. Must have ability to connect the barriers to each other to ensure continuity in the barrier integrity and stopping capability.

2.1.5. Units must have the option to pivot and transition into an operational gate that can be operated by one individual.

2.1.5. The Barriers MUST be painted Safety Yellow in color for maximum visibility. Barrier may be deployed in roadways and must meet traffic safety requirements for visibility.

2.1.6. Easy to assemble, deploy and dismantle. No tools required for assembly.

2.1.7. Must have an open structure design, with no solid metal/bullet resistant piece being more than 18” in width, as to not provide an active shooter cover and concealment.

2.1.8. Individual barrier units must fold for easy carrying. storage, and transportation.

2.1.9. Bottom edges of the barriers must be protected by aluminum covers (for pedestrian safety).

3. SPECIFICS:

3.1. Shipping must be included in the quotation.

3.2. Contractor shall deliver and install the system at the Main Gate (Bldg. 6410) on Mountain Home AFB ID, 83648

3.3. Delivery will be no later than 60 days after date of contract (DOC).