Power Cart Salient Characteristics Sheet.pdf
PDF 79 KB Posted
- Attached to
- Solicitation - Mobile Aircraft Power Carts
- Solicitation number
- FA487725QA151
About this file
This is a Salient Characteristics document specifying the minimum requirements for Mobile Aircraft Power Carts to be delivered to the 55th RGS, as part of solicitation FA487725QA151 for the Department of the Air Force Air Combat Command.
The required power cart must meet specific electrical requirements including 380-480V 3-phase input with 93A full load current at 480 VAC, and 115V L-N/200V L-L 3-phase 400Hz output. Key features include a built-in maintenance diagnostic system, digital touch screen control panel, USB communications port, internal step-up transformer, surge protection, IGBT active front end, and aircraft safety interlock. The unit must come with a maintenance-free wheel kit, electronic manual, 100-foot input cable with HBL4100P7W plug, and 60-foot AC output cable with aircraft plug and safety interlock. A one-year warranty is required.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Solicitation-Mobile Aircraft Power Carts.pdf | ||
| Provisions and Clauses_Power Carts.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SALIENT CHARACTERISTICS
FOR
Mobile Aircraft Power Cart
1.0. SCOPE OF WORK:
All proposed products shall meet or exceed the following minimum specifications outlined in this Salient Characteristics. All items shall be delivered to the 55th RGS.
1.1. PRODUCT PERFORMANCE SPECIFICATION:
Item must meet the following minimum specifications:
SPECIFICATIONS
Headers Please adjust Headers to item requirement
Electrical
Requirement:
• Input: 380 to 480 V +10%/-15%, 3-phase, 50/60 Hz; full load input current 93 A (at 480 VAC)
• Output: 115 V L-N / 200 V L-L, 3-phase, 4-wire, 400 Hz
Warranty: • 1 Year
Features: • Built-in maintenance diagnostic system
• Digital touch screen control panel
• External communications port access, front panel USB
• 208 to 480 V internal step up transformer
• Input surge protection IAW IEEE C62.41, Category B
• 5% Max. AC input current distortion, IGBT active front end
• AC output contactor “connect/disconnect” device with aircraft safety interlock
• Maintenance free wheel kit
• Electronic Operator and Maintenance Manual
Accessories: • 100 feet input cable, single jacket 3-conductor with ground and
HBL4100P7W plug
• AC output cable, 60 feet, banded multiple conductors with aircraft plug and safety interlock
File details come from the government source that posted it. Updated .