This document is a Question and Answer (Q&A) document related to Request for Quote (RFQ) #FA487724QA318 for a Security Camera System. The key details are:
The RFQ is for the procurement of a security camera system for the 355th Air Mobility Squadron (AMXS) at Nellis Air Force Base, Nevada. The system requires 10 cameras, which will replace the existing 7 cameras. The new cameras can reuse the existing mounts and cabling where possible. The customer will not disclose the nature of the existing system failure. All cameras are mounted inside the building on poles. The system does not require a monitor, mouse, or keyboard, but does require USB ports for a mouse and keyboard. The recorder will not be stored in a lockable enclosure, as it will be located in an environmentally controlled building.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 5. 355 AMXS SECURITY CAMERA SYSTEM Q&A II.pdf | ||
| 4. Customer Photos of Existing System_Redacted.pdf | ||
| 2. CLS FA487724QA318 355 AMXS SEC CAMERAS FINAL I.pdf | ||
| 3. RFQ FA487724QA318 COMMON QUESTION AND ANSWERS V1.pdf | ||
| 1. Salient Characteristics SECURITY CAMERA SYSTEM_Redacted.pdf | ||
| SOLICITATION 355 AMXS SECURITY CAMERA SYSTEM FA487724QA318.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
QUESTIONS AND ANSWERS II
RFQ# FA487724QA318
SECURITY CAMERA SYSTEM
Received: 24 July 2024
QUESTION 1: The current system (based on the pictures) has 7 cameras. The project is also described as 8 to 10 cameras. Please confirm the quantity of cameras requested.
ANSWER: Customer recounted, and 10 cameras are needed.
QUESTION 2: Please confirm that the new cameras are replacing the existing cameras and can re-use the mounts (where possible) and cabling.
ANSWER: New cameras are replacing existing cameras
Customer intends to re-use mounts, if supported by new cameras
Customer intends to re-use cabling, if supported by new cameras
QUESTION 3: Please describe the nature the failure of the existing system (e.g., is the recorder failed? Are the cameras failed? Is the cabling still working?)
ANSWER: This information will not be disclosed as it is not required to submit a quote
QUESTION 4: The existing (and therefore new) cameras are described as inside vice outside mounting. The pictured camera is mounted on a pole. This is normally an outside, not inside mounting technique. Please confirm that all of the cameras being replaced are inside and pole mounted.
ANSWER: The location of all cameras are inside the building
Customer have poles installed inside the building because it is a warehouse, and this set up best suits the configuration of our building
QUESTION 5: The specifications do not describe any monitor, keyboard, or mouse. Please confirm that these are not required.
ANSWER: Customer does not require monitor, mouse or keyboard
Customer does require USB ports for a mouse and keyboard
QUESTION 6: Due to the security nature of the camera system, please clarify if the recorder needs to be in a lockable, ventilated enclosure.
ANSWER: The unit will not be stored in a lockable enclosure. It will be located in an environmentally controlled building