Attachment_Q and A Form.pdf
PDF 135 KB Posted
- Attached to
- Wheel Washer
- Solicitation number
- FA483026Q0051
About this file
This is a Questions and Answers (Q&A) form documenting government responses to contractor inquiries regarding a C-130 wheel washing equipment procurement at Moody Air Force Base, Georgia.
The solicitation addresses a wheel washing system for C-130 aircraft with the following specifications: wheels measuring 24.5 inches in diameter, 17 inches in height, and weighing 175 pounds maximum. The equipment cabinet or tank must be constructed of stainless steel. While no specific wash-cycle time is mandated, the government prefers a minimum capacity of one wheel per 30 minutes. Wash temperature, spray pressure, and flow specifications are not defined beyond a requirement for heated water. The system must operate on 480V, 3-phase, 50-60Hz power. Water and compressed-air supply are available on-site at Building 644, Moody AFB GA 31699-1509; drainage will be handled by Hazardous Materials (HAZ) personnel, and ventilation requirements are not specified. While no specific filtration or wastewater-recycling features are mandated, the government prefers oil separation and filtration capabilities. No cleaning solution is required as part of the contract, and no safety certifications (UL, OSHA, ANSI, or NFPA) are mandated. None of the government responses resulted in changes to the Statement of Work or design drawings.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Wheel Washer Statement of Work.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
23 CONS Questions & Answers Form
Solicitation Reference Question/Comment Government Response
Resulted in change of SOW or drawings?
Change Reference
# Example: Atch 1 - SOW, Para. 2.4.(c)
Example: Please confirm the submission requirement for a detailed design IAW Phase 3 or Phase 5 (final design), prior to award.
Yes/No
Example:
Atch 1 – SOW, para # or Atch 2 – Design Drawings, pg#
Maximum C-130 wheel dimensions and weight
24.5 inches diameter, 17 inched height, 175 pounds
No
Required cabinet or tank material and steel grade stainless steel No
Required wash-cycle time or wheels-per-hour capacity no specific requirement, preference would be (1 wheel per 30 minutes minimum)
No
Required wash temperature, spray pressure, and flow no specific requirement, the only specification is for it to be heated
No
Required voltage, phase, amperage, and frequency 480V, 3 phase, 50-60hz No
Water-supply, drainage, compressed-air, and ventilation requirements
There is water and air supply in the room, no drainage as HAZ will come and drain it, no vent requirements
No
Required filtration, oil-separation, or wastewater-recycling features
There are no specific requirements, prefer oil separation and filtration
No
Exact installation and delivery address, including the building number
8009 Sijan St. Bldg 644 Moody AFB GA 31699-
No
Whether the cleaning solution must be included with the equipment
No solution required, we procure what is specified for us to use
Any required safety certifications, such as UL, OSHA, ANSI, or
NFPA
There are no requirements
23 CONS Questions & Answers Form
File details come from the government source that posted it. Updated .