785asbestos.pdf
PDF 736 KB Posted
- Attached to
- QSEU 12-2002, Repair Infrared Heaters
- Solicitation number
- FA4830-13-B-0002
About this file
BLDG 785 Asbestos Report
View the file
Other files
Show all 44
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Moody AFB, Selected Buildings Asbestos Inspection Report February 2010
4.15 Building MB 785 (Sheet Metal and Battery Shop)
Building MB 785 is a large building containing a variety of aircraft maintenance shops. The building was constructed by the U.S. military in 1966. Photograph available here.
A total of 54 samples were collected from 7 different material types in Building 785 during the inspection visit of 5 and 6 November 2009. Sampled materials included gypsum board and finishing compound, vinyl wall covering, vinyl cove molding and mastic, vinyl floor tiles and mastics, ceiling tiles, thermal system insulation, and duct insulation mastic. Table MB 785-1 provides a listing of the samples with their analytical results. Figures MB 785A-loc and MB 785B-loc show a floor plan of the building showing the sample locations.
Table MB 785-1 Suspect ACBM Samples in Building MB 785
Sample ID Sample Material Sample Location Analytical Result
MB-785-01-001 Gypsum board and finishing compound –
Type I
Room 42, behind W wall access door locking jamb above molding
NAD
MB-785-01-002 Gypsum board and finishing compound –
Type I
Room 32, behind door in SE corner, above cove molding
NAD
MB-785-01-003 Gypsum board Room 14, bottom of electrical panel on W wall
NAD
MB-785-01-004 Gypsum board w/vinyl wall covering – Type II
Room 31, N wall in area previously damaged
NAD
MB-785-01-005 Gypsum board w/vinyl wall covering – Type II
Room 30, W wall by access door locking jamb above molding
NAD
MB-785-02-001 2’ x 2’ ceiling tile w/fissures and pits –
Type I
Room 1, ceiling in alcove between rooms 13 and 4, by S wall
NAD
MB-785-02-002 2’ x 2’ ceiling tile w/fissures and pits –
Type I
Room 4, first floor, ceiling above east entry doors
NAD
MB-785-02-003 2’ x 4’ ceiling tile w/fissures and pits –
Type II
Room 32, first floor, ceiling above fixed bench, NW corner
NAD
MB-785-02-004 2’ x 4’ ceiling tile w/fissures and pits –
Type II
Room 1, ceiling in alcove between Rooms 13 and 4, by S wall
NAD
NAD=No asbestos detected
Sample ID Sample Material Sample Location Analytical Result
MB-785-02-005 2’ x 2’ ceiling tile, smooth– Type III
Room 44A, first floor, Ceiling by S wall, 6’ from W wall
NAD
MB-785-02-006 2’ x 2’ ceiling tile, smooth– Type III
Room 44A, first floor, ceiling by E wall, 6’ from S wall
NAD
MB-785-03-001 Beige 12” x 12” floor tile
– Type I
Floor at entry door alcove to Room 13
NAD
MB-785-03A-001 Black mastic for beige 12” x 12” floor tile
Floor at entry door alcove to Room 13
NAD
MB-785-03-002 Beige 12” x 12” floor tile
– Type I
Floor at N entry door to Room 4 in NW corner
NAD
MB-785-03B-002 Black mastic for beige 12” x 12” floor tile
Floor at N entry door to Room 4 in NW corner
NAD
MB-785-03-003 Green 12” x 12” floor tile – Type II
Room 19A, N end of hallway, floor at locking jamb of W access door
NAD
MB-785-03C-003 Clear mastic for green 12” x 12” floor tile
Room 19A, N end of hallway, floor at locking jamb of W access door
NAD
MB-785-03-004 Green 12” x 12” floor tile – Type II
Room 19A, floor at doorway to cleaning room, S end of hallway
NAD
MB-785-03D-004 Clear mastic for green 12” x 12” floor tile
Room 19A, floor at doorway to cleaning room, S end of hallway
NAD
MB-785-03-005 Scored 12” x 12” floor tile – Type III
Room 12, floor at access doorway on W wall
2% Chrysotile
MB-785-03E-005 Mastic for scored 12” x 12” floor tile
Room 12, floor at access doorway on W wall
5% Chrysotile
MB-785-03-006 Scored 12” x 12” floor tile w/carpet mastic pattern– Type III
Room 25, floor at access doorway on N wall
NAD
MB-785-03F-006 Black Mastic for scored 12” x 12” floor tile
Room 25, floor at access doorway on N wall
NAD
MB-785-03FF-006 Yellow Mastic for scored 12” x 12” floor tile
Room 25, floor at access doorway on N wall
NAD
MB-785-03-007 Beige 12” x 12” floor tile w/red streaks– Type IV
Room 41A, floor at S side of locker room entry doorway
NAD
MB-785-03G-007 Black Mastic for Beige 12” x 12” floor tile w/red streaks
Room 41A, first floor, S side of locker room entry doorway
NAD
MB-785-03-008 Beige 12” x 12” floor tile w/red streaks– Type IV
Room 41A, floor at S wall between lockers
NAD
MB-785-03H-008 Black Mastic for Beige 12” x 12” floor tile w/red streaks
Room 41A, floor at S wall between lockers
NAD
MB-785-03-009 Black 12” x 12” floor tile
– Type V
Room 40, floor at locking jamb of access door
NAD
MB-785-03I-009 Clear Mastic for Black 12” x 12” floor tile
Room 40, floor at locking jamb of access door
NAD
MB-785-03-010 Black 12” x 12” floor tile
– Type V
Room 19, floor in SW corner NAD
MB-785-03J-010 Clear Mastic for Black 12” x 12” floor tile
Room 19, floor in SW corner NAD
MB-785-03-011 Light Brown 12” x 12” floor tile – Type VI
Room 13A, floor under metal shelf unit, NE corner
NAD
MB-785-03K-011 Mastic for light brown 12” x 12” floor tile
Room 13A, floor under metal shelf unit, NE corner
NAD
MB-785-03-012 Light Brown 12” x 12” floor tile – Type VI
Room 13A, floor under S end of shelf unit
NAD
MB-785-03L-012 Mastic for light brown 12” x 12” floor tile
Room 13A, floor under S end of shelf unit
NAD
MB-785-03-013 Dark brown 9” x 9” floor tile
Room 42, Floor near W wall doorway locking jamb
NAD
MB- 785-03M-013 Mastic for Dark brown 9” x 9” floor tile
Room 42, Floor near W wall doorway locking jamb
NAD
MB-785-03-014 Dark brown 9” x 9” floor tile
Room 42, Floor at E wall doorway to Room 44
NAD
MB-785-03N-014 Mastic for Dark brown 9” x 9” floor tile
Room 42, Floor at E wall doorway to Room 44
NAD
MB-785-04-001 Brown cove molding Room 4, W wall by entrance to locker room
NAD
MB-785-04A-001 Mastic for brown cove molding
Room 4, W wall by entrance to locker room
NAD
MB-785-04-002 Brown cove molding, no mastic present
Room 10, by locking jamb side of entry door
NAD
MB-785-04-003 Brown cove molding, no mastic present
Room 44A, at hinge jamb of access door
NAD
MB-785-06-001 Hard, white, friable joint mud on pipe elbow
Mechanical Room B, first floor, from elbow of scrap pipe found in Mechanical Room B on floor
65% Chrysotile
MB-785-06-002 Hard, white, friable pipe joint mud on pipe fitting
Mechanical Room B, first floor, NE corner 9’ above floor, elbow on 2” and 3” pipe
NAD
MB-785-06-003 Fiberglass Lagging w/cover
Mechanical Room B, first floor, NE corner, 9’ above floor, lagging near sample 002
NAD
MB-785-06-004 Elbow – fiberglass and foil w/white duct tape wrap
Room 6, first floor, SE corner above drop ceiling
NAD
MB-785-06-005 Hard, white, friable pipe joint mud on pipe fitting
Room 4, first floor, above entry door to Room 5, above drop ceiling, from elbow at capped end
65% Chrysotile
MB-785-06-006 Hard, white, friable pipe joint mud on pipe fitting
Room 35, first floor, SW corner from elbow on wall, turning towards heater
65% Chrysotile
MB-785-06-007 Hard, white, friable pipe joint mud on pipe fitting
Room 35, first floor, along S wall, 9’ above floor, 30’ E of SW corner, from 4” condensate trap line
45% Chrysotile
MB-785-06-008 Hard, white, friable pipe joint mud on pipe fitting
Room 37, first floor, from valve fitting above heater in SE corner
45% Chrysotile
MB-785-06-009 Hard, white, friable pipe joint mud on pipe fitting
Room 25, first floor, approx.
center of ceiling area – piping above ceiling (T-fitting)
15% Chrysotile
MB-785-07-001 Black duct insulation mastic
Approx. center of Room 4 above drop ceiling, E side of duct above ceiling disperser vent
7% Chrysotile
MB-785-07-002 Black duct insulation mastic
Room 14, first floor, approx center of N wall, above drop ceiling, from duct terminus
8 % Chrysotile
NAD=No asbestos detected
Of the sampled materials in Building MB 785, the following contained asbestos:
• 12” x 12” floor tile, unknown color, and black mastic found in a maintenance space (Room 12). NESHAPS Classification: Category I Non-friable ACM assessed as being in damaged condition. The floor tile had been overlain with carpet and carpet mastic; it contains 2% chrysotile asbestos and the mastic contains 5% chrysotile asbestos.
Photograph available here.
• Thermal System Insulation on piping in various locations throughout MB 785; the pipe insulation is fiberglass lagging with hard, troweled-on pipe-joint insulation. NESHAPS Classification: Friable RACM, removal required prior to repair, renovation or demolition.
The pipe joint mud contains chrysotile (15%-65%) asbestos; it was assessed as being in damaged condition and it lacks protective covering. The pipe insulation is normally accessible only to maintenance personnel, as it is either above drop ceiling systems or suspended high above open-ceiling shops. This material should be labeled, maintained and monitored for deterioration. Photograph available here.
• Black Duct Insulation Mastic found on duct insulation above Rooms 4, 13, 15, and 16.
NESHAPS Classification: Category I Non-friable ACM found in good condition. This material contains 7% to 8% Chrysotile asbestos but is relatively inaccessible to building occupants. HVAC maintenance personnel should be cautioned to avoid any work practices which would sand, grind, abrade, or pulverize the mastic. Photograph available here.
Table MB 785-2 lists the ACBM at Building MB 785, and Figure MB 785-ACBM shows the location and areal extent of the material.
Table MB 785-2 ACBM at Building MB 785
Material Sample ID Condition Potential for Disturbance
Material Quantity
NESHAPS
Class
12” x 12” Unknown color floor tile and black FT mastic
MB-785-03-005 Damaged High ~300 SF Category I Non-friable
ACM
TSI, Pipe Joint Insulation w/fiberglass lagging
MB785-06-001,
005,006,007,008 and 009
Damaged Moderate >100 Fittings, >1000 Linear
Feet
RACM
Black Duct Insulation
Mastic
MB-785-07-001
and 002
Good Low 125 LF Category I Non-friable
ACM
SF = Square feet LF= Linear Feet
Figure MB 785A-loc
Figure MB 785B-loc
Figure MB 785-ACBM
Moody AFB, Selected Buildings February 2010 Asbestos Inspection Report
Moody Air Force Base Building 785
South Elevation
Sample ID: MB-785-03-005; Doorway into Room 12
Description: Unknown color 12” x 12” floor tile and black floor tile mastic
Sample ID: MB-785-06-001; Scrap on floor of Mechanical Room B
Description: TSI, Fiberglass pipe lagging and mudded pipe joint insulation in canvass wrap
Sample ID: MB-785-06-009; above ceiling in Room 25
Description: TSI, Fiberglass pipe lagging and mudded pipe joint insulation in canvass wrap
Sample ID: MB-785-07-001; Approximate center of Room 4, above drop ceiling at disperser
Description: Black duct insulation mastic on foil/fiberglass duct insulation
| TABLE OF CONTENTS |
| TABLES |
| ACRONYMS AND ABBREVIATIONS |
| 1.0 PURPOSE, SCOPE, AND LIMITATIONS |
| 1.1 Purpose |
| 1.2 Site Information |
| Table 1-1 |
| 1.3 Scope of Services |
| 1.4 Refocusing the Scope of Services |
| 1.5 Limitations |
| 2.0 ASBESTOS BACKGROUND INFORMATION |
| 3.0 ASBESTOS INSPECTION |
| 3.1 Modification of AHERA Inspection Method |
| 3.2 Previous Investigation Reports |
| 3.3 Sampling of Suspect ACBM |
| 3.4 Sample Numbering |
| 3.5 Assumed ACBM |
| 3.6 Room Nu |
| 3.7 Recommendations |
| 4.0 INSPECTION RESULTS – MOODY AIR FORCE BASE |
| 4.1 Building MB 104 (Child Development Center) |
| Table MB 104-1 |
| Table MB 104-2 |
| 4.2 Building MB 112 (Accounting and Finance |
| Table MB 112-1 |
| 4.3 Building MB 134 (Moody AFB Post Office) |
| Table MB 134-1 |
| Table MB 134-2 |
| 4.4 Building MB 325 (Moody Inn Dormitory) |
| Table MB 325-1 |
| Table MB 325-2 |
| 4.5 Building MB 571 (Dining Hall) |
| Table MB 571-1 |
| Table MB 571-2 |
| 4.6 Building MB 574 (Air Conditioning Plant) |
| Table MB 574-1 |
| Table MB 574-2 |
| 4.7 Building MB 617 (Security/Police) |
| Table MB 617-1 |
| 4.8 Building MB 717 (Paint Hangar) |
| Table MB 717-1 |
| Table MB 717-2 |
| 4.9 Building MB 757 (Communications) |
| Table MB 757-1 |
| Table MB 757-2 |
| 4.10 Building MB 768 (Painting Hanger/Storage) |
| Table MB 768-1 |
| Table MB 768-2 |
| 4.11 Building MB 769 (Refueling Maintenance Shop) |
| Table MB 769-1 |
| 4.12 Building MB 770 (A10 AMU) |
| Table MB 770-1 |
| 4.13 Building MB 772 (A-10 Parts Store) |
| Table MB 772-1 |
| 4.14 Building MB 776 (CAMS Office) |
| Table MB 776-1 |
| 4.15 Building MB 785 (Sheet Metal and Battery Shop) |
| Table MB 785-1 |
| Table MB 785-2 |
| 4.16 Building MB 788 (A10 Fuels System MX and MX Hangar) |
| Table MB 788-1 |
| Table MB 788-2 |
| 4.17 Building MB 803 (COMM BIDDS Switching) |
| Table MB 803-1 |
| 4.18 Building MB 804 (Thrift Shop) |
| Table MB 804-1 |
| Table MB 804-2 |
| 4.19 Building MB 841 (Base General Storage Facility) |
| Table MB 841-1 |
| 4.20 Building MB 901 (Moody Field Club) |
| Table MB 901-1 |
| 4.21 Building MB 907 (Equipment Rental/MWR Warehouse) |
| Table MB 907-1 |
| Table MB 907-2 |
| 4.22 Building MB 908 (Airman’s Attic and Multi-purpose Storage Building) |
| Table MB 908-1 |
| Table MB 908-2 |
| 4.23 Building MB 917 (Army COE) |
| Table MB 917-1 |
| Table MB 917-2 |
| 4.24 Building MB 918 (Headquarters 23rd CES) |
| Table MB 918-1 |
| Table MB 918-2 |
| 4.25 Building MB 921 (SABER Contractor) |
| Table MB 921-1 |
| 4.26 Building MB 932 (Supply, Contracting and 820thSFS) |
| Table MB 932-1 |
| Table MB 932-2 ACBM at Building MB 932 |
| 4.27 Building MB 934 (Base Supply, Paint and HazMat Storage) |
| Table MB 934-1 |
| Table MB 934-2 |
| 4.28 Building MB 976 (Motor Pool Special Purpose and Heavy Equipment VehicleMaintenance) |
| Table MB 976-1 |
| 4.29 Building MB 978 (CE Storage) |
| 4.30 Building MB 979 (Honor Guard and CEH Warehouse) |
| Table MB 979-1 |
| 4.31 Building MB 980 (CE Material Control Office and Warehouse) |
| Table MB 980-1 |
| Table MB 980-2 |
| 4.32 Building MB 1107 (Rocket Test Cell) |
| Table MB 1107-1 |
| 4.33 Building MB 1108 (Missile Assembly Shop) |
| Table MB 1108-1 |
| Table MB 1108-2 |
| 4.34 Building MB 1111 (Munitions Maintenance Administration Building) |
| Table MB 1111-1 |
| Table MB 1111-2 |
| 4.35 Building MB 1219 (PME Storage) |
| Table MB 1219-1 |
| Table MB 1219-2 |
| 4.36 Building MB 1220 (Youth Center and CE Storage) |
| Table MB 1220-1 |
| Table MB 1220-2 |
| 4.37 Building MB 1500 (820th Security Forces Group) |
| Table MB 1500-1 |
| 4.38 Building MB 1501 (Communications Receiver Building) |
| Table MB 1501-1 |
| 4.39 Building MB 1806 (Golf Course Clubhouse) |
| Table MB 1806-1 |
| APPENDIX A FLOOR PLANS FOR INSPECTED BUILDINGS |
| Figure MB 104-loc 1 |
| Figure MB 104-ACBM |
| Figure MB 112-loc |
| Figure MB 134-loc |
| Figure MB 134-ACBM |
| Figure MB 325A-loc |
| Figure MB 325B-loc |
| Figure MB 325A-ACBM |
| Figure MB 325B-ACBM |
| Figure MB 571-loc |
| Figure MB 571-ACBM |
| Figure MB 574-loc |
| Figure MB 574-ACBM |
| Figure MB 617-loc |
| Figure MB 717A-loc |
| Figure MB 717B-loc |
| Figure MB 717A-ACBM |
| Figure MB 717B-ACBM |
| Figure MB 757-loc |
| Figure MB 757-ACBM |
| Figure MB 768-loc |
| Figure MB 768-ACBM |
| Figure MB 769-loc |
| Figure MB 770-loc |
| Figure MB 772-loc |
| Figure MB 776-loc |
| Figure MB 785A-loc |
| Figure MB 785B-loc |
| Figure MB 785-ACBM |
| Figure MB 788-loc |
| Figure MB 788-ACBM |
| Figure MB 803-loc |
| Figure MB 804-loc |
| Figure MB 804-ACBM |
| Figure MB 841-loc |
| Figure MB 901-loc |
| Figure MB 907-loc |
| Figure MB 907-ACBM |
| Figure MB 908-loc |
| Figure MB 908-ACBM |
| Figure MB 917-loc |
| Figure MB 917-ACBM |
| Figure MB 918A-loc |
| Figure MB 918B-loc |
| Figure MB 918C-loc |
| Figure MB 918A-ACBM |
| Figure MB 918B-ACBM |
| Figure MB 918C-ACBM |
| Figure MB 921-loc |
| Figure MB 932A-loc |
| Figure MB 932B-loc |
| Figure MB 932C-loc |
| Figure MB 932D-loc |
| Figure MB 932A-ACBM |
| Figure MB 932B-ACBM |
| Figure MB 932C-ACBM |
| Figure MB 932D-ACBM |
| Figure MB 934-loc |
| Figure MB 934-ACBM |
| Figure MB 976-loc |
| Figure MB 978-loc |
| Figure MB 979-loc |
| Figure MB 980A-loc |
| Figure MB 980B-loc |
| Figure MB 980A-ACBM |
| Figure MB 980B-ACBM |
| Figure MB 1107-loc |
| Figure MB 1108-loc |
| Figure MB 1108-ACBM |
| Figure MB 1111-loc |
| Figure MB 1111-ACBM |
| Figure MB 1219-loc |
| Figure MB 1219-ACBM |
| Figure MB 1220-loc |
| Figure MB 1220-ACBM |
| Figure MB 1500-loc |
| Figure MB 1501-loc |
| Figure MB 1806-loc |
| APPENDIX B PHOTOGRAPHS OF ACBM |
| Moody Air Force Base Building 104 |
| Moody Air Force Base Building 112 |
| Moody Air Force Base Building 134 |
| Moody Air Force Base Building 325 |
| Moody Air Force Base Building 571 |
| Moody Air Force Base Building 574 |
| Moody Air Force Base Building 617 |
| Moody Air Force Base Building 717 |
| Moody Air Force Base Building 757 |
| Moody Air Force Base Building 768 |
| Moody Air Force Base Building 769 |
| Moody Air Force Base Building 770 |
| Moody Air Force Base Building 772 |
| Moody Air Force Base Building 776 |
| Moody Air Force Base Building 785 |
| Moody Air Force Base Building 788 |
| Moody Air Force Base Building 803 |
| Moody Air Force Base Building 804 |
| Moody Air Force Base Building 841 |
| Moody Air Force Base Building 901 |
| Moody Air Force Base Building 907 |
| Moody Air Force Base Building 908 |
| Moody Air Force Base Building 917 |
| Moody Air Force Base Building 918 |
| Moody Air Force Base Building 921 |
| Moody Air Force Base Building 932 |
| Moody Air Force Base Building 934 |
| Moody Air Force Base Building 976 |
| Moody Air Force Base Building 978 |
| Moody Air Force Base Building 979 |
| Moody Air Force Base Building 980 |
| Moody Air Force Base Building 1107 |
| Moody Air Force Base Building 1108 |
| Moody Air Force Base Building 1111 |
| Moody Air Force Base Building 1219 |
| Moody Air Force Base Building 1220 |
| Moody Air Force Base Building 1500 |
| Moody Air Force Base Building 1501 |
| Moody Air Force Base Building 1806 |
Figure MB 803-loc
File details come from the government source that posted it. Updated .