Solicitation Amendment FA480924Q00630002 SF 30.pdf
PDF 582 KB Posted
- Attached to
- TRANE HVAC systems Federal contract opportunity
- Solicitation number
- FA480924Q0063
About this file
This document is a Solicitation Amendment to Solicitation FA480924Q0063 for TRANE and Carrier HVAC systems. The amendment corrects the model numbers for two contract line items (CLINs 0001 and 0002) for a building located at Seymour Johnson AFB. The overall requirement is for HVAC systems across 5 different buildings on the base, including 20-130 ton air-cooled chillers and rooftop units. Key details include the CLIN descriptions, brands, model numbers, performance specifications, and warranty information. The solicitation is being administered by the Department of the Air Force Air Combat Command. The amendment extends the offer due date but does not change the award date.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Solicitation Amendment FA480924Q00630003 SF 30.pdf | ||
| Solicitation Amendment - FA480924Q00630003.pdf | ||
| Solicitation Amendment - FA480924Q00630002.pdf | ||
| Solicitation Amendment FA480924Q00630001 SF 30.pdf | ||
| Solicitation Amendment - FA480924Q00630001.pdf | ||
| Carrier Brand Name Justification - Redacted.pdf | ||
| Solicitation - FA480924Q0063.pdf | ||
| Tab 2A - HVAC Chiller System Justification and Approval 7 Aug 19 Redacted.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
R
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers is extended. is not extended.
Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended, by one of the following methods:
(a) By completing items 8 and 15, and returning copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;
or (c) By separate letter or electronic communication which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by letter or electronic communication, provided each letter or electronic communication makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
12. ACCOUNTING AND APPROPRIATION DATA (If required)
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.
IT MODIFIES THE CONTRACT/ORDER NUMBER AS DESCRIBED IN ITEM 14.
CHECK ONE A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT ORDER
NUMBER IN ITEM 10A.
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation data, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER (Specify type of modification and authority)
E. IMPORTANT: Contractor is not is required to sign this document and return copies to the issuing office.
14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15A. NAME AND TITLE OF SIGNER (Type or print) 16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)
15B. CONTRACTOR/OFFEROR
(Signature of person authorized to sign)
15C. DATE SIGNED 16B. UNITED STATES OF AMERICA
(Signature of Contracting Officer)
16C. DATE SIGNED
Previous edition unusable STANDARD FORM 30 (REV. 11/2016) Prescribed by GSA FAR (48 CFR) 53.243
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT 1. CONTRACT ID CODE PAGE OF PAGES
2. AMENDMENT/MODIFICATION NUMBER 3. EFFECTIVE DATE 4. REQUISITION/PURCHASE REQUISITION NUMBER 5. PROJECT NUMBER (If applicable)
6. ISSUED BY CODE 7. ADMINISTERED BY (If other than Item 6) CODE
8. NAME AND ADDRESS OF CONTRACTOR (Number, street, county, State and ZIP Code) (X) 9A. AMENDMENT OF SOLICITATION NUMBER
9B. DATED (SEE ITEM 11)
10A. MODIFICATION OF CONTRACT/ORDER NUMBE
10B. DATED (SEE ITEM 13)
CODE FACILITY CODE
SECTION SF 30 BLOCK 14 CONTINUATION PAGE
SUMMARY OF CHANGES
Supplies or Services & Prices or Costs
The following CLIN(s) / SLIN(s) / ELIN(s) were modified:
INFORMATION FROM TO CHANGED BY
Model Number CRMANDPR011A00 48-50FC-8-16-01PD
INFORMATION FROM TO CHANGED BY
Model Number 48-50FC-8-16-01PD CRMANDPR011A00
Description/Specifications/Statement of Work
Miscellaneous text in this section has been modified to:
CLIN Description Expanded:
CLIN 0001 / Building 2402
Description: 15 Ton WeatherMaker Single Packaged Rooftop Unit, Low gas heat, 15 Tons, Single circuit, two stage cooling, Standard Packaging, Direct drive, EcoBlue, medium static fan, Al/Cu cond. coil - Al/Cu evap coil, Electro-Mechanical Ctl W7212
Brand: Carrier
Model #: 48-50FC-8-16-01PD
CLIN 0002 / Building 2402
Description: Manual Damper, ACC SRT, 50% F/O AIR DAM
Brand: Carrier
Model #: CRMANDPR011A00
CLIN 0003 / Building 2402
Description: Compatible Curb Adapter
Brand: Aladdin or equal
Model #: CACA1075 or equal item.
CLIN 0004 / Building 2121
Description: 20 - 130 Ton Air Cooled (CGAM), 60 hertz, 460 volt 3 phases, high efficiency/performance, full factory refrigerant charge (R-454B) with factory installed freeze protection, refrigerant isolation valves (discharge valve), UL listed to US and Canadian safety standard, ASHRAE 90.1 all versions up to 2016, AHRI certified, Factory installed flow switch - set point 60 cm/sec, Std cooling (40 to 65F/4.44 to 18C), grooved pipe connection, factory insulation 0.75", peromance based on water, wide ambient (0 to 125F/-18 to 52C), lanced aluminum fins, across the line starter /direct on line, single point connection main line unit power-ancillary items require other power, Circuit breaker-high fault rated control panel, enclosure type UL 1995 rated for outdoor applications, LonTalk/Tracer Summit interface, High A short circuit rating, elastomeric isolators, with
FA480924Q00630002
water strainer factory installed, super quiet, architectural louvered panels, 5 year parts warranty whole unit, 5 year labor warranty whole unit, 5 year refrigerant warranty.
Brand: Trane
Model #: CGAM130F2--2AXD2A1A1A1AX-A1D1A2XXX8BXB1A3A1D1XXL-X
CLIN 0005 / Building 4817
Description: 20 - 130 Ton Air Cooled (CGAM), Air-Cooled Scroll Packaged Chiller, Startup Included - Trane Service must start equipment for warranty to be honored, 30 nominal tons, Factory Assigned, 60 hertz, 208 volt 3 phases, Extra efficiency/performance, Refrigerant Charge R-454B, With factory installed freeze protection, Refrigerant isolation valves (discharge valve), UL Listed to U.S. and Canadian safety std via ETL - 2019, ASHRAE 90.1/CSA C743 - No Compliance, AHRI certified, Factory installed flow switch - set point 60 cm/sec, Standard Cooling, Grooved pipe connection, Factory insulation 0.75", Performance based on water, Wide Ambient, Lanced aluminum fins, Across the line starter/direct on line, Single point connection main line unit power-ancillary items require other power, Circuit breaker, Enclosure Type UL 60335 Rated for Outdoor Applications, Dual high head pump, Pump flow ctrl by var speed drive, With buffer storage tank, Default A short circuit rating, Elastomeric isolators, With water strainer factory installed, Super quiet, Architectural louvered panels, 5 year parts warranty whole unit, 5 year refrigerant warranty, 5 year labor warranty whole unit.
Brand: Trane
Model #: CGAM030A2**3EXD2A1A3A1AX*A1C2BXXXXX8B1A1A3A1D1XXLXX
CLIN 0006 / Building 3811
Description: 52 Ton Air Cooled (CGAM), Air-Cooled Scroll Packaged Chiller, Startup Included - Trane Service must start equipment for warranty to be honored, 52 nominal tons, 208 volt 3 phases 60 hertz, Extra efficiency/performance, Refrigerant charge (R-454B), With factory installed freeze protection, Refrigerant isolation valves (discharge valve), ETL listed to US and Canadian safety standard,ASHRAE 90.1/CSA C743 - 2019 Compliance, AHRI certified, Factory installed flow switch - set point 60 cm/sec, Std cooling, Grooved pipe connection, Factory insulation 0.75", Performance based on water, Wide ambient, Lanced aluminum fins, Across the line starter/direct on line, Single point connection main line unit power-ancillary items require other power, Circuit breaker, Enclosure Type UL 60335 Rated for Outdoor Applications, BACnet MS/TP Interface, Dual high head pump, Pump flow ctrl by var speed drive, With buffer storage tank, Default A short circuit rating, Elastomeric isolators, With water strainer factory installed, Super quiet, Architectural louvered panels, 5 year parts warranty, 5 year refrigerant warranty, 5 year labor warranty whole unit.
Brand: Trane
Model #: CGAM060a2--2AXD2A1A1A1AX-A1A1A2XXXXXXA1A3A1D1XXL-X
CLIN 0007 / Building 4916
Description: 20 - 130 Ton Air Cooled (CGAM), Air-Cooled Scroll Packaged Chiller, Startup Included - Trane Service must start equipment for warranty to be honored, 120 nominal tons, 460 volt 3 phases 60 hertz, High efficiency/performance, Refrigerant Charge R-454B, With factory installed freeze protection, Refrigerant isolation valves (discharge valve), ETL Listed to US/Canadian Safety Standard, ASHRAE 90.1/CSA C743 - 2019 Compliance, AHRI certified, Factory installed flow switch - set point 60 cm/sec, Standard Cooling, Grooved pipe connection, Factory insulation 0.75", Performance based on water, Wide Ambient, Lanced aluminum fins, Across the line starter/direct on line, Single point connection main line unit power-ancillary items require other power, High Fault Circuit Breaker, Enclosure Type UL 60335 Rated for Outdoor Applications, BACnet MS /TP Interface, No Wireless Options, Default A short circuit rating, Elastomeric isolators, With water strainer factory installed, Super quiet, Architectural louvered panels, 5 year parts warranty whole unit, 5 year refrigerant warranty, 5 year labor warranty whole unit.
Brand: Trane
Model #: CGAM120F2**2EXD2A1A3A1AX*A1A2B4XXXXXXA1A3A1D1XXLXX
FA480924Q00630002
| IDCode: J |
| Page: 1 |
| Pages: 3 |
| AmendNo: 0002 |
| EffDate: 09 Sep 2024 |
| ReqNo: |
| ProjNo: |
| IssCode: FA4809 |
| AdmCode: |
| IssuedBy: FA4809 4TH CONS SQDN CC |
1570 WRIGHT BROTHERS AVE BLDG 2903, CP 919 722 5417
SEYMOUR JOHNSON AFB, NC 27531-2456
UNITED STATES
JONATHAN TRUSLOW, Email: jonathan.truslow@us.af.mil Telephone: 722-1728 AdminBy:
SCD: PAS:
| ContractorNameAdd: |
| Code: |
| FacCode: |
| SolChg: 1 |
| SolNo: FA480924Q0063 |
| SolDate: 27 Aug 2024 |
| AwardChg: Off |
| AwardNo: |
| AwardDate: |
| Amended: 1 |
| OffrExt: Off |
| OffrNoEx: 1 |
| NoCopies: 1 |
| ApprData: See Section G - Contract Administration Data |
| ChgeOrd: Off |
| ChgeOrder: |
| Modify: Off |
| SuppAgre: Off |
| SuppAuth: |
| ModOthr: Off |
| OthrSpec: |
| NoReq: Off |
| Require: Off |
| Copies: |
| Descript: The purpose of this amendment is to correct the model numbers for CLINs 0001 and 0002. |
| ContNameTitle: |
| CoNameTitle: Aaron A. Vanvynckt |
| ContDate: |
| CODate: 10 Sep 2024 |