Salient Characteristics - VM Pilot Unit UTC Mobile Workshop.pdf

PDF 103 KB Posted

Attached to
UFR #59 VM Mx Pilot Unit UTC Mobile Workshop
Solicitation number
FA480324QB054
Issued by

About this file

This document contains the Salient Characteristics for an Expandable Deployment Workshop required under a federal contract opportunity. The key details are:

The expandable workshop must be configured to fit within the military's 463L cargo management system, with the ability to expand the working area by 300% when deployed. It must have secure access panels, electrical power connections for 110/220V single-phase power, a compressed air system, and LED lighting. The workshop is required to support vehicle maintenance operations and be air-transportable in a single pallet position.

The related federal contract opportunity is Solicitation Number FA480324QB054 for an "UFR #59 VM Mx Pilot Unit UTC Mobile Workshop", issued by the Department of the Air Force Air Combat Command. The contractor shall provide the Expandable Industrial Shop Unit meeting the stated salient characteristics.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SALIENT CHARACTERISTICS

FOR

EXPANDABLE DEPLOYMENT WORKSHOP

Airlift Worthiness

Expandable workshop must be configured to fit within the military’s 463L cargo management system.

Specifically, it must have the size and fixtures that allow it to be secured into a military cargo aircraft roller and rail system. It must also be equipped with tie-down and sling points that will permit transport by truck and by helicopter sling movement.

Accessibility

The expandable workshop must be configured with panels, hinged and the bottom, that when opened expand the working area of the workshop an additional 300%. Specifically, each of the two 88” (463L system) sides must fold down, allowing a workspace that more than 240 inches. Unit must be configured with one divider (approx. 108”) to create two separate workspaces and provide mounting points for electrical fixtures, compressed air plumbing and fittings, as well as lighting. Unit must be configured with a cover over each side, covering all sides, when the shelter is expanded.

Security

All access openings and drop panels must be securable with a durable, military-grade latch and locking system.

Electrical Power

The expandable workshop must be configured with suitable electrical connections and power management equipment to permit 110/220-volt single phase power. Unit must have suitable connections for external power supply from surrounding military bare base or commercial power grid as well as internal connections for an internal generator with sufficient cable length to operate the generator a safe distance from the workshop. Unit must have a suitable load/circuit breaker panel in addition to conduit and receptacles to connect to tool and equipment.

Compressed Air Capability

The expandable workshop must be configured with compact, scroll type air compressor capable of approximately 8 cubic feet per minute at 100 PSI. System must include a separate air receiver/storage tank, 20 gallons minimum. System must provide plumbing and fittings to both side of the shelter.

Lighting

The expandable workshop must be configured with LED lighting in each side of the workshop sufficient to safely light the work area.

File details come from the government source that posted it. Updated .