The document is a Salient Characteristics specification for a Military Working Dog (MWD) Trailer, detailing precise requirements for a 10-stall tandem axel stainless steel transport trailer. The trailer must accommodate military working dogs with specific design features including secure enclosures, climate control capabilities maintaining temperatures between 45-85 degrees, individual stall dimensions of 29" X 40" X 36", and comprehensive environmental controls such as ducted air conditioning, ventilation, and drainage systems.

Key technical specifications include a secondary air conditioner, hot dog pager alarm system to monitor temperature extremes, welded interior bar doors with latching mechanisms, uniformly diffused lighting, and exterior placards reading "Caution: Military Working Dog" in black or red lettering. The trailer design emphasizes animal safety and comfort, with requirements for floors that protect dogs' feet, allow easy cleaning and sanitization, provide sufficient movement space, and shield animals from extreme weather conditions. This specification is part of a Sources Sought notice by the Department of the Air Force Global Strike Command to conduct market research for potential trailer manufacturers under NAICS code 336212 Truck Trailer Manufacturing.

View the file

Other files

File Type Posted
Sources Sought MWD Transport trailer.docx DOCX document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Military Working Dog Trailer – Salient Characteristics

ITEM

NUMBER

Description
QUANTITY
UNIT
0001
10 Stall Tandem Axel Stainless Steel Trailer

• No sharp points or edges inside enclosure

• Must contain animal securely

• Enable animal to remain dry and clean

• Provide shelter in extreme temperatures and weather conditions

• All contact surfaces inside enclosure must enable regular cleaning and sanitizing

• Floor must be constructed in a manner that protects animal’s feet and legs from injury, and do not allow animals feet to pass through any openings

• Provide sufficient space for animals to turn about freely, to stand, sit, and lie down comfortably

- Climate Control

• Ambient temp must range between 45-85 degrees

- Large Stall (10)

• Must meet dimensions of 29” X 40” X 36” per stall

- Secondary Air Conditioner

• Required for size of trailer (10 stalls)

- Hot Dog Pager

• Offers an audio alarm via pager to notify staff if ambient temperature inside the stall reaches over 85 degrees or below 45 degrees.

-Ducted Air Conditioning

• One per stall (10 total)

• Must be recessed

- Drainage

• Drain holes in each stall floor

• Must allow for water, urine, and cleaning solution to be pushed through hole

- Lettering/Decal

• Must be placarded on all four sides

• Must read “Caution: Miliary Working Dog”

• Must be colored in black or red lettering

- Welded Inner Bar Doors

• Placed on the interior behind outside door

• Must have latching/locking mechanism

• One per stall

- Ventilation

• Requires auxiliary ventilation in form of fans, blowers, or air conditioning

• Must be adequate to minimize odors, drafts, ammonia levels, moisture condensation, and exhaust fumes.

-Lighting

• Must be lighted well enough to permit proper cleaning and inspection of the facility, and observation of dogs.

• Must be regular diurnal lighting cycle of either natural or artificial light.

• Must be uniformly diffused throughout facility and provide sufficient illumination to aid in maintaining good housekeeping practices, cleaning, and inspection of animals.