CATM_Lighting_Layout.pdf

PDF 749 KB Posted

Attached to
LED Lighting Fixtures Federal contract opportunity
Solicitation number
FA4659-16-Q-0026
Issued by
Department of the Air Force Air Mobility Command

About this file

Lighting Layout.

View the file

Other files for this federal contract opportunity

Other files attached to LED Lighting Fixtures, newest first.
File Type Posted
Product_Specs.pdf PDF
LED-Combo.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

J

PC

A-1.7 A-3.5

AA

R-6

1 2 3 4 5 6 7 8 9 10

A-3

B

A

RA

RB

A-2

RC

RD

RE

RF

RG

RH

RJ

RK

ELECTRICAL

FIRING

PLATFORM

DOWNRANGE

STORAGE

R-1

7 METER

15 METER

25 METER

L2

E1 31

C2 A2

A2

F2 F2 31

C2

A1

C2

C2

A1

A2

F1

F2

A2

C2

E1

L1

L1

L1

A2

L2

L2

L2

C1

C1

C1

C1

C1

C1

C1

C1

C1

C1

C1

T1

T1

T1

T1

T1

T1

T1

T1

T1

T1

T1

T1

T1

T1

T1

T1

T1

T1

T1

T1

T1

T1

34,36 T2

34,36 T2

34,36 T2

34,36 T2

34,36 T2

34,36 T2

38,40 T2

38,40 T2

38,40 T2

38,40 T2

38,40 T2

T1

T1

T1

T1

T1

T1

T1

T1

T1

T1

T1

T1

T1

T1

T1

T1

T1

T1

T1

T1

T1

T1

30,32 T2

30,32 T2

30,32 T2

30,32 T2

30,32 T2

T1

T1

T1

T1

T1

T1

T1

T1

T1

T1

T1

T1

26,28 T2

26,28 T2

26,28 T2

T1

T1

T1

T1

T1

26,28 T2

26,28 T2

26,28 T2

T1 2

T1 T1

T1

T1

F1

A2

A2

A2

A2

A2

A2

A2

A2

A2

A1

A1

A1

C2

C2

C2

C2

A1

C2 29

A1

A1

A1

C2

A1

C2

A1

C2

A1

A1

C2

C2

A19'AFF

7'-6"AFF 7'-6"AFF

9' AFF

7'-6"AFF7'-6"AFF

EL01

EL01

EL02

B1

EL03

EL04

EL04

L-2 L-1

LP-1

a,b c,d e,f,g,h eee e e e e e e e e e e e e e e e e e e e fff f f f f f f f f f f f f f f f f f f f ggg g g g g g g g g g g g g g g g g g g g h h h h h h h h h h h h h h h h h h h h h h a b b b b b b b b b b b aaaa aa a a a a a a a a c c c c c c c c c c c c c c c c dd

TRAP

MAINTENANCE

L-1

SEE DETAIL 2/E-111.

EL05

EL06"h"

"e","f","g"

L-1

L-1

L-1

L-1

L-1 6 L-1

8EL07

EL07

EL07

EL07

L-1

L-1

L-1

L-1

16EL07EL07EL07

EL07

L-1

L-1

L-1

L-1

24EL07EL07EL07

EL07

L-1 26,28 L-1

30,32EL07EL07

L-1 34,36

L-1

38,40EL07

EL07

EL08

L-1

EL10

EL09

L-1

EL10

EL11EL11EL11

INFRARED HEATERS (TYP)

(SEE MECHANICAL PLAN)

GAS UNIT HEATER

(SEE MECHANICAL

PLAN)

GAS UNIT HEATER

(SEE MECHANICAL

PLAN)

L-1

#10

CHASE

CHASE

EL12 EL12

GENERAL NOTES

A. COORDINATE LIGHT FIXTURE LOCATIONS WITH OTHER

BUILDING COMPONENTS SUCH AS HVAC EQUIPMENT,

DUCTWORK, STRUCTURAL MEMBERS, BAFFLING, AND TARGET

EQUIPMENT.

B. PROVIDE DIGITAL WALL CONTROL STATIONS, POWER PACKS,

RELAY PACKS, AND CAT-5E CABLING AS REQUIRED FOR

COMPLETE AND FULLY OPERATIONAL LIGHTING CONTROL

SYSTEM.

D. PROVIDE #12 AWG, THHN/THWN, 0-10VDC CONNECTIONS AS

REQUIRED BETWEEN POWER / RELAY PACKS AND LIGHT

FIXTURES BEING CONTROLLED. ROUTE IN CONDUIT AS

RECOMMENDED BY THE MANUFACTURER.

E. PROVIDE DEDICATED NEUTRAL CONDUCTORS FOR EACH 20

AMP, SINGLE POLE, BRANCH CIRCUIT UNLESS OTHERWISE

NOTED. COLOR CODE EACH NEUTRAL TO IDENTIFY

CORRESPONDING PHASE CONDUCTOR.

C. PROVIDE CONDUIT FOR CAT-5E LIGHTING CONTROL CABLING.

COORDINATE WITH LIGHTING CONTROLS MANUFACTURER.

F. AIM FLOODLIGHTS FOR TARGETS AS DIRECTED BY THE

OWNER.

ON OFF

ON OFF

ON OFF

ON OFF

ON/OFF

ON/OFF

ON/OFF

ON/OFF

LED NIGHTTARGETS

G

FL

RM

RED

NOTE:

COORDINATE COVERPLATE ENGRAVING WITH USER.

COVERPLATE LABELING KEY:

7 7 METER FLOODLIGHTS

15 15 METER FLOODLIGHTS

25 25 METER FLOODLIGHTS

G GENERAL TARGET AREA LIGHTS

FL FIRING LINE LIGHTS

RM RANGE MASTER STATION LIGHTS

RED FIRING LINE RED LIGHTS

25 25 METER DIMMABLE LIGHTS

LED INDICATOR

LIGHT (TYPICAL)

(e,f,g,h) (c,d) (a,b)

LEO A DALY Company 2014

A

B

C

D

A

B

C

D

2 3 4 5

P L

A N

N I N

G A

R C

H I T

E C

T U

R E

E N

G I N

E E

R I N

G I

N T

E R

I O

R S

ES

T

S ec o n d A ve n u e

So u th

Su it e

M in n ea p o li s, M N

-2

U

SA

T el

-3

-8

F ax

-3

-4

GR

AN

D

FO

RK

S

AF

B, N D

CO

NT

RA

CT

S

EL

EM

EN

T

9 C

IV

IL

EN

GI

NE

ER

S

QU

AD

RO

N

AI

R

MO

BI

LIT

Y

CO

MM

AN

D

DE

PA

RT

ME

NT

O

F

TH

E

AI

R

FO

RC

E

PR

OJ

EC

T

NU

MB

ER

PL

OT

S

CA

LE

A S

IN

DI

CA

TE

D

PL

OT

D

AT

E:

CH

K

BY

DW

N

BY

DE

SI

GN

ED

B Y:

FI

LE

N

AM

E:

DA

TE

1 2 3 4 5

Sheet of 36

/1

/2

:1

:0

A

M

LIG

HT

IN

G

PL

AN

E-111

JF

SD

A

DD

/R

EP

AI

R

SM

AL

L A

RM

S

RA

NG

E

GR

AN

D

FO

RK

S

AF

B, N

OR

TH

D

AK

OT

A

1-

5-

/23

/1

SW

N

RD

J

RD

J

ISSUED FOR BID/

CONSTRUCTION

JF

SD

_B

4_ E-

/23

/1

SCALE: 1/8" = 1'-0"E-111

1 LIGHTING PLAN - LEVEL 1

NTRUE

NORTH

FLOOR PLAN KEYNOTES

EL01 PROVIDE NLIGHT #NPODM-2P-DX-IV-LT (OR APPROVED EQUAL)

DIGITAL TWO CHANNEL, SIX BUTTON, CONTROL STATION WITH

ON/OFF AND RAISE/LOWER OPERATION FOR EACH CHANNEL.

PROVIDE DIGITAL CAT-5E CONNECTIONS AS RECOMMENDED BY

THE MANUFUACTURER.

EL02 PROVIDE NLIGHT #NPODM-4P-IV-LT (OR APPROVED EQUAL)

DIGITAL FOUR CHANNEL, EIGHT BUTTON, CONTROL STATION TO

CONTROL TARGET AREA LIGHT FIXTURES. PROVIDE DIGITAL

CAT-5E CONNECTION IN CONDUIT TO RELAY PANELS IN ROOM

102.

EL03 INTERLOCK EXISTING WARNING BEACON WITH HVAC SYSTEM.

COORDINATE WITH OWNER AND MECHANICAL CONTRACTOR.

PROVIDE 120V POWER CONNECTION FROM CIRCUIT SERVING

HVAC CONTROLLER.

EL04 PROVIDE NLIGHT NPODM-IV-LT (OR APPROVED EQUAL) DIGITAL

SINGLE CHANNEL, TWO BUTTON, CONTROL STATION WITH

ON/OFF OPERATION FOR CHANNEL. PROVIDE DIGITAL CAT-5E

CONNECTIONS AS RECOMMENDED BY THE MANUFUACTURER.

EL05 PROVIDE TWO NLIGHT #NPANEL-2-480 (OR APPROVED EQUAL)

RELAY PANELS TO CONTROL GENERAL DOWNRANGE LIGHTING

FIXTURES. RELAY PANELS TO HAVE 0-10V DIMMING CAPABILITIES

FOR FUTURE USE.

EL06 PROVIDE THREE NLIGHT #NPANEL-4 (OR APPROVED EQUAL)

RELAY PANELS, ONE EACH, TO CONTROL DOWNRANGE

FLOODLIGHT FIXTURES AT 7M, 15M & 25M RESPECTIVELY. RELAY

PANELS TO HAVE 0-10V DIMMING CAPABILITIES FOR FUTURE USE.

EL07 ROUTE HOMERUN TO PANELBOARD VIA APPROPRIATE LIGHTING

RELAY PANEL IN ROOM 102.

EL08 PROVIDE NLIGHT #NSP5-PCD-LT (OR APPROVED EQUAL) RELAY

PACK WITH DIMMING. MOUNT IN ROOM 102.

EL09 PROVIDE TORK #2001 (OR APPROVED EQUAL) PHOTOCONTROL

TO CONTROL EXTERIOR LIGHTING CIRCUIT. MOUNT ON SIDE OF

BUILDING AT APPROXIMATELY 10' AFF. AIM NORTH.

EL10 ROUTE TO PANELBOARD VIA PHOTOCONTROL.

EL11 REUSE EXISTING BRANCH CIRCUIT WIRING BETWEEN TYPE L1

LIGHT FIXTURES ON FRONT OF BUILDING.

EL12 REINSTALL AND RECONNECT EXISTING LIGHT FIXTURES AND

ASSOCIATED BRANCH CIRCUIT CONDUITS AND CONDUCTORS

BETWEEN GRIDS RA AND RH. EXTEND BRANCH CIRCUITING AS

REQUIRED TO ACCOMMODATE INSTALLATION TO ROOF

STRUCTURE AND BAFFLING. COORDINATE INSTALLATION WITH

GENERAL CONTRACTOR.

SCALE: NTSE-111

2 RANGE MASTER DIGITAL LIGHTING CONTROL STATION

N O

D

ES

C

R

IP

T

IO

N D

A T E

IS

SU

ED

F O

R B

ID

C

O N

ST

R U

C T

IO

N /2

/1

File details come from the government source that posted it. Updated .