Attachment_3-JFSD201139_Drawings.pdf
PDF 24 MB Posted
- Attached to
- Repair Fire Suppression, Barnes Hall Dorm 319 Federal contract opportunity
- Solicitation number
- FA4659-13-R-0003
About this file
Attachment 3-Drawings FA4659-13-R-0003/ JFSD 201139
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Amendment-Change_of_response_date_and_time.pdf | ||
| FA4659-13-R-0003-Solicitation-JFSD201139.pdf | ||
| Past_and_Present_Performance_Questionnaire-JFSD201139.pdf | ||
| Attachment_6-Financial_Institution_Reference_Sheet.docx | DOCX document | |
| Attachment_1-Wage_determination.pdf | ||
| Attachment_7-_Waiver_Green_Procurement.pdf | ||
| Attachment_2-JFSD201139_Specifications.pdf | ||
| Attachment_4-JFSD201139_Material_Submittal_Schedule.pdf | ||
| Solicitation_Cover_Letter-JFSD201139.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
JFSD201139GRAND FORKS AFB, NORTH DAKOTA
DEC 2012
ISSUED FOR BID/CONSTRUCTION
REPAIR FIRE SUPPRESSION
BARNES HALL DORM 319
1. CONTRACTOR SHALL PROTECT EXISTING BUILDING AND SITE MATERIALS SCHEDULED TO REMAIN, AND SHALL BE RESPONSIBLE FOR DAMAGE TO
SAME RESULTING FROM WORK UNDER THIS CONTRACT. CONTRACTOR SHALL RESTORE DAMAGED EXISTING BUILDING AND SITE MATERIALS TO
THEIR ORIGINAL CONDITION. CONTRACTOR SHALL REMOVE ALL CONSTRUCTION - RELATED MATERIALS AND DEBRIS FROM ALL BUILDING AND SITE
AREAS.
2. CONTRACTOR SHALL EXERCISE CAUTION TO AVOID ANY DAMAGE WHEN PERFORMING EARTHWORK, PAVING, OR ANY CONSTRUCTION IN THE
VICINITY OF EXISTING UTILITIES, BUILDINGS, AND LANDSCAPING. WHEN NEAR EXPECTED UTILITY LINE LOCATION, HAND-DIG OR HYDRO-EXCAVATE TO
LOCATE UTILITIES PRIOR TO MACHINE DIGGING.
3. ALL LANDSCAPED AREAS OF SITE WHICH ARE DISTURBED BY WORK OF THIS PROJECT SHALL BE RETURNED TO THEIR ORIGINAL CONDITION.
SODDED AREAS SHALL BE SODDED, BUSHES AND TREES SHALL BE REPLACED WITH SAME SPECIES AND SIZE MATERIAL, ETC.
4. CONTRACTOR SHALL INSPECT SITE AND FIELD VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO COMMENCING CONSTRUCTION. NOTIFY
CONTRACTING OFFICER IMMEDIATELY OF ANY DISCREPANCIES.
5. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS, AND SHALL BE RESPONSIBLE FOR THE SAME. COORDINATE ALL WORK AND SHOP DRAWINGS
WITH OTHER TRADES.
6. CONTRACTOR SHALL COORDINATE ON-SITE STORAGE OF BUILDING MATERIALS, EQUIPMENT, AND TRASH CONTAINERS WITH GOVERNMENT PRIOR TO
COMMENCEMENT OF WORK. SEE SPEC SECTION 01000 FOR ADDITIONAL REQUIREMENTS, INCLUDING REQUIRED TEMPORARY FACILITIES PLAN.
7. ALL WORK SHALL COMPLY WITH APPLICABLE CODES, REGULATIONS, AND ORDINANCES.
8. ALL MATERIALS AND EQUIPMENT OF THE SAME TYPE SHALL BE SUPPLIED BY THE SAME MANUFACTURER, AND SHALL BE NEW, OF THE BEST QUALITY
AND DESIGN, AND FREE FROM DEFECTS.
9. ALL ITEMS ARE NEW UNLESS SPECIFICALLY IDENTIFIED AS EXISTING.
10. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION OF ALL WORK. CONTRACTOR SHALL ANTICIPATE AREAS WHERE THE INSTALLATION OF
MECHANICAL AND ELECTRICAL WORK WILL BE RESTRICTED, CONGESTED, OR DIFFICULT TO INSTALL, AND SHALL COORDINATE INSTALLATION
BETWEEN THE TRADES.
11. CONTRACTOR SHALL COORDINATE ALL MECHANICAL AND ELECTRICAL ITEMS WITH THE GENERAL CONSTRUCTION.
12. CONTRACTOR SHALL COORDINATE AND SCHEDULE ALL NECESSARY UTILITY OUTAGES WITH THE GOVERNMENT CONSTRUCTION REPRESENTATIVE
PRIOR TO PROCEEDING WITH SUCH WORK TO INSURE THAT OPERATIONS IN ADJACENT OCCUPIED PORTIONS OF THE BUILDING ARE NOT
INTERRUPTED OR RESTRICTED WITHOUT PRIOR APPROVAL.
13. CONTRACTOR SHALL BE RESPONSIBLE FOR WEATHERTIGHTNESS OF THE EXISTING BUILDING AT ALL TIMES DURING CONSTRUCTION. CONTRACTOR
SHALL INCLUDE ALL NECESSARY PROVISIONS TO ACCOMPLISH THIS, INCLUDING, BUT NOT LIMITED TO, SEALING OF ALL ROOF AND WALL
PENETRATIONS AT THE END OF EACH WORKING DAY.
14. CONTRACTOR SHALL AVOID DISTURBING EXISTING COMMUNICATION LINES, CABLE TRAYS, FIRE ALARM SYSTEM COMPONENTS, ETC. LOCATED ABOVE
CORRIDOR CEILINGS. IF THESE ITEMS ARE DISTURBED THROUGH THE WORK OF THIS PROJECT, CONTRACTOR SHALL RESTORE DISTURBED ITEMS TO
THEIR ORIGINAL CONDITION.
NO SCALE
PROJECT LOCATION MAP
MINOT
BISMARCK
W E
S
N
WILLISTON
FORKS
JAMESTOWN
AFB
GRAND
FORKS
FARGO
GRAND
NO SCALE
STATE OF NORTH DAKOTA -
VICINITY MAP
G-001
C O
V E
R S
H E
E T
G R
A N
D F
O R
K S
A F
B
N D
C O
N T
R A
C T
S E
L E
M E
N T
C
IV
IL
E
N G
IN
E
E R
S Q
U A
D R
O N
A B C D E F G
Sheet of
NUMBER
REFERENCE
SHEET
A
IR
M O
B
IL
IT
Y
C O
M M
A N
D
D E
P A
R T
M E
N T
O F
T H
E A
IR
F
O R
C E
D R
A W
IN
G
N U
M B
E R
P L O
T S
C A
L E
T O
F O
R
/2 -S
IZ
E
P L O
T D
A T
E
C H
K B
Y
D W
N B
Y
D E
S
IG
N E
D B
Y
F
IL
E N
A M
E
D A
T E
S y m b o l
D e s c ri p tio n D a te
A p p ro v e d
S y m b o l
A p p ro v e d
D a te D e s c ri p tio n
D E
C
G J H
G J H
K L M
D E
C
IS
S
U E
D F
O R
B
ID
/C O
N S
T R
U C
T
IO
N
J F
S D
R E
P A
IR
F
IR
E
S U
P P
R E
S S
IO
N
B A
R N
E S
H A
L L D
O R
M
G R
A N
D F
O R
K S
A F
B N
O R
T H
D A
K O
T A
MAIN GATE
ACCESS
CONTRACTOR'S
1599 J St.
HOSPITAL
TO GRAND
FORKS, ND
PROJECT
LOCATION
H ST.
T U
S K
E G
E E
A
IR
M E
N
B
L V
D
EIELSON
STREET
U .S
H
IG
H
W A
Y
25TH ST NE
T H
A V
E
N S
W
E
SOUTH
GATE
J
JUNCTION
JOINT
JOIST
JUNCTION BOX
K
KICK PLATE
KEY LOCK
KITCHEN
KEYK
KP
JC
JB or J-BOX
JST
JCT
KL
kcmil or KCM
KCP
KIP
KIT
JT
F F
FA
FC
FCJ
FCG
F.D.
FE
FDN
FEC
FHC
FH
F.E.S
FEB
FD
C (cont.)
COMMUNICATIONS
COMPRESSIBLE
COMMON
COMBUSTION
COMBINATION
CORNER
COVERED
CONSTRUCTION JOINT
CONSTRUCTION
CONNECTION
CORRIDOR
CONTINUOUS
CONFERENCE
CONCRETE
FIRE HOSE CABINET
FOOT CANDLE
FRESH AIR
FAHRENHEIT
FACING
FIRE HYDRANT
FOUNDATION
FIRE DAMPER
FLOOR DRAIN
FIRE EXTINGUISHER CABINET
FLOOR CONSTRUCTION JOINT
FIRE EXTINGUISHER BRACKET
FLARED END SECTION
FIRE EXTINGUISHER
L
LABORATORY
LUMEN
KILOWATT
KILOVOLTS
LENGTH
LOADING
POUNDS
LUMBER
LAVATORY
LAUNDRY
LOAD
L kV kW kvar
LAB
kVA
LG
LD
LDG
LBR
LAT
LAV
LBS
LAU
LONG RADIUS
LIVING ROOM
LIGHT
LOW POINT
LONGITUDINAL
LINTEL
M
MAINTENANCE
THOUSAND
MACHINE
LIGHTING
LIGHT WEIGHT
M
LP
LT
LR
LONG
LNTL
LPS
L.R.
LIS
MAINT.
MACH
LT. WT.
LWT
LTG
LINEARLIN
FIN.
FIG.
FIX.
FLEX
FLG
FL or FLR
FLUOR
FLASH
FPM
FR
FPRF
F.S.
FTG.
FT.
FRG
FP
COURSE
CAST STONE TILE
COUNTER SINK
CEMENT PLASTER
CASEMENT
CARRIAGE
CENTER
TRANSFORMER
CABINET UNIT HEATER
CONDENSING UNIT
CEILING VENT
CUBIC YARDS
CARPET TILE
CERAMIC TILE or CURRENT
CYCLES PER SECOND (HERTZ)
CORROSIVE RESISTANT STEEL
GAS
G
FWC
G
G
GA
GALV
GAL
GEN
GFE
G.F.I. or GFI
G.C.O.
G.F.C.I.
D
DATUM
DOUBLE ACTING
CERAMIC WALL TILE
DRY BULB
CYLINDER
DOUBLE
DEGREE
DUMMY CONTOL JOINT
DIRECT CURRENT
DOOR CLOSER
DEPRESSION
DEPARTMENT
DOWELED CONTROL JOINT
PENNY (as in nail - 10d)
COLD WATER
FW
FLUORESCENT
FLOORING
FLEXIBLE
FLASHING
FIXTURE
FINISH
FLOOR
FIGURE
FIRE WATER
FOOTING
FULL SIZE
FURRING
FIRE PROOF
FEET PER MINUTE
FIRE PROTECTION
FEET
FRAME
GALVANIZED
GUTTER
GAGE or GAUGE
GALLON
GENERAL
GOVERNMENT FURNISHED
GOVERNMENT FURNISHED EQUIPMENT
GROUND FAULT INTERRUPTOR
GROUND CLEANOUT
FABRIC WALL COVERING
CONTRACTOR INSTALLED
COM
COMP
COMB
COMB
COMM
CONN
CONSTR
CONF.
COV
COR
CORR
CONT
CONC.
A
AB
A/C
AC
ACSR
ACI
AREA DRAIN
ACOUSTIC
AGGREGATE
ACST
A.D.
AD
A.F.F.
AGG
AHU
AFFF
ADMIN.
AIR CONDITIONING
ANCHOR BOLT
ACCESS DOOR
ADMINISTRATION/ADMINISTRATIVE
AMERICAN CONCRETE INSTITUTE
AQUEOUS FILM FORMING FOAM
AIR HANDLING UNIT
ABOVE FINISH FLOOR
STEEL REINFORCED
ALUMINUM CONDUCTOR
ALTERNATING CURRENT
CRG
CRES
C.P.S. ~
CPL
CSMT
CST
CRSE
CS
CTR
CTL
CU YD
CUH
CV
CU
CT
AREA INLET
ALTERNATE
ALUMINUM
AIC
A.I.
AISC
AL
ALT
A.L.
APPROVED
ANSI
AP
A.R.I.
ARCH
APPROX.
APPD
AMPEREAMP
ACTIVE LEAF
APPROXIMATE
ACCESS PANEL
ARCHITECTURAL OR ARCHITECT
STANDARDS INSTITUTE
AMERICAN NATIONAL
AMERICAN REFRIGERATION
STEEL CONSTRUCTION
AMERICAN INSTITUTE of
CAPACITY (SYM RMS)
AMPS INTERRUPTING
CWT
CYL
D d
DB
DA
D.C.J.
DCJT
DC
DBL
DEPR
DEPT
DEG
DCL
ASSISTANT
ASPHALT
ASBESTOS
AVERAGE
AUTOMATIC
ASPH
ASB
ATC
ASSIST.
AVG
AUTO
AWG
AWC
B
ANGLE
BOUNDARY
BOOKCASE
BOARD
BATT INSUL
BC
BDY
BD
BB BULLETIN BOARD
BATT INSULATION
ACOUSTICAL WALL COVERING
AMERICAN WIRE GAUGE
ACOUSTICAL TILE CEILING
INSTITUTE
CW
CONSTR JT.
METAL
MECHANICAL
MAXIMUM
MATERIAL
METAL LATH
MINIMUM
MANHOLE
MANAGEMENT
MANUFACTURER
MFG
M & B
MER
MET.
MECH
MCJ
MAX
MC
ML
MGMT
M.H.
MGT
MIN
MG
MFR
MAT or MATL
N
MOTOR
MOUNTED
MASTIC
MONOLITHIC
ASSOCIATION
NORTHN
MO
MT
MOT
MSTC
MTD
MONO
N.C.
NFPA
NEMA
NEC
NCO
MOULDINGMLDG
GL
GOVT.
GPM
GRS
GR
GSU
GRTG
GND or GRND
H
GWB
GWT
GYP
HB
HC
HBD
DOUBLE HUNG
DISSEMANATION
DUCT HEATER
DIRECTOR
DIMENSION
DIAGONAL
DIAMETER
DRINKING FOUNTAIN
DOWN
DRAIN
DOOR
DISCONNECT
DRESSED & MATCHED
DOWN SPOUT
DAMPPROOFING
DISTRIBUTION
HD
HDRL
HDR
HM
HP
HIP
H.PT.
HDW
HR
H.S.
HT
HTR
HTG
HW
H.W.
HSGYP
DOWELS
EAST
EACH
E
DIRECT EXPANSION
EXHAUST AIR
FINISH SYSTEM
EXPANSION JOINT
ELEVATOR
EMERGENCY EYEWASH & SHOWER
EXTERIOR INSULATION &
ELECTRIC or ELECTRICAL
ELEVATION - GRADE OR BUILDING
ENTERING AIR TEMPERATURE
ESTIMATED MAXIMUM DEMAND
DRAWING
HCD
GRATING
GOVERNMENT
GROUND
GRADE
HANDICAPPED
HEAD
HARDBOARD
HOSE BIBB
GYPSUM
HALON CONTAINMENT DAMPER
GALVANIZED RIGID STEEL CONDUIT
GRAZED STRUCTURAL UNITS
GLAZED WALL TILE
GYPSUM WALLBOARD
GALLONS PER MINUTE
HIGH PRESSURE
HIGH STRENGTH
HIGH POINT
HOUR
HEADER
HORSE POWER
HOLLOW METAL
HARDWARE
HANDRAIL
HEIGHT
HOT WATER
HEATER
HEADWALL
HEATING
HIGH-STRENGTH GYPSUM PLASTER
GLASS
NOT REQUIRED
NUMBERNU OR NO.
N.R.
N.O.
I
HYD
Hz
I.E.
I.D.
IC
I or EF
IN
IES
INT.
I.P.
INV.
INSUL.
EQUAL
ENTRANCE
EACH SIDE
ESTIMATE
EQUIPMENT
EXPLOSION PROOF
EXCAVATE
EXPLOSION
EXTERIOR
EXPANSION
EXPOSED
EXISTING
EXHAUST
EXIT DEVICE
ENTERING WATER TEMPERATURE
ELECTRIC WATER COOLER
HYDRAULIC
INCH
INVERT ELEVATION
INSIDE DIAMETER
INTERCOM
IRON
IRON PIPE
INTERIOR
INSULATION
ILLUMINATING ENGINEERING SOCIETY
INVERT or INVERTER
HERTZ
NIC
HOT WATER HEATER
ENCLOSURE
HWH
DIA or Ø
DH
DH
DF
DISSEM
DIR
DIM
DIAG
DISC
D & M
DN
DIST
DRN
DS
DR
DP
BUILDING
BLOCK
BITUMINOUS
BOTTOM OF
BLOCKING
BEAM
BIT
BLDG
BLK
BL
BM
BLKG
B.O.
B.M.
BOTTOM
BRIDGING
BRACING
BRACKET
BRICK
BENT
BEARING
BOT
BR
BRDG
BRCG
BRK
BT
BRKT
BRG
BENCH MARK
BUILDING LINE
BULLET RESISTANT
DWLS
DX
E
EA
EAT
EA.
EES
EIFS
EJ
ELEC.
EMD
ELEV
CAPACITY
C
BTUH
BUR
CAP
C or CND
CC
CEMENT
CHIMNEY
CAST IRON
CB
CE
CFM
CEM
CHIM
CFT
CI
C.I.
BTU PER HOUR
COVER ELEVATION
CURB INLET
CATCH BASIN (OR CIRCUIT BREAKER)
CONDUIT (FOR RACEWAY -
CERAMIC FLOOR TILE
CUBIC FEET PER MINUTE
CENTER TO CENTER
BUILT-UP ROOFING
DWG
BTU BRITISH THERMAL UNIT
ENT
EQ.
E.P.
ES
EWT
EWC
EST
EQUIP.
EXC
EXD
EXIST.
EXH
EXT
EXPN
EXPL
EXP
CIRCUIT
CHECKED
CAULKING
CLERK
CEILING
CJ
CKT
CKD
L
CLK
CLKG
CLG
C or CL
CLOSET
CLOSED
CLEANOUT
COUNTER
CLO
CLOS
CMP
CNTR
CMU
2CO
CO
CONTROL JOINT
CENTER LINE
CIRCUIT BREAKER
CARBON DIOXIDE
CONCRETE MASONRY UNITS
CORRUGATED METAL PIPE
COLUMNCOL
ENCL
CIRCULARCIR
EL or ELEV.
MASONRY
BEJ BRICK EXPANSION JOINT
MAS
GALVANIZED IRONGI
DET DETAIL
ABBREVIATIONS
MATTE - GLAZED TILE
MECHANICAL EQUIPMENT ROOM
MASONRY CONTROL JOINT
LEAVING WATER TEMPERATURE
LAWN IRRIGATION SYSTEM
LEAVING AIR TEMPERATURE
KILOVOLT AMPERES REACTIVE
KILOPOUND (1000 LBS)
KEENE'S CEMENT PLASTER
MANUFACTURERS ASSOCIATION
NATIONAL ELECTRICAL CODE
NON COMMISSIONED OFFICER
NATIONAL FIRE PROTECTION
MANUFACTURING
NORMALLY OPEN
NATIONAL ELECTRICAL
NOT IN CONTRACT
NORMALLY CLOSED
METAL THRESHOLD
MASONRY OPENING
MOTOR GENERATOR
MATCHED & BEADED
MEDICINE CABINET
LIGHT PROOF SHADE
KILOVOLT AMPERES
KILO CIRCULAR MIL
JANITOR CLOSET
MDF MEDIUM DENSITY FIBERBOARD
FCO FLOOR CLEANOUT
MOTOR STARTERMS
AECS AUTOMATED ENTRY CONTROL SYSTEM
ELECTRICAL SHEETS)
CPT CARPET
CTG CLEAR TEMPERED GLASS
CLEAR TEMPERED INSULATING GLASSCTIG
CATV CABLE TELEVISION
FOS FACE OF STUD
FSF FABRIC SILT FENCE
C.F.C.I. CONTRACTOR FURNISHED
CONTRACTOR INSTALLED
GOVERNMENT INSTALLED
CONTRACTOR FURNISHEDC.F.G.I.
G.F.G.I. GOVERNMENT FURNISHED
GOVERNMENT INSTALLED
HPL HIGH PRESSURE LAMINATE FLOORING
GLASS FIBER REINFORCED PLASTERGFRP
IDS INTRUSION DETECTION SYSTEM
F.O. FIBER OPTIC
D (cont.)
G-002
A B
B R
E V
IA
T
IO
N
S G
R A
N D
F O
R K
S A
F B
N
D C
O N
T R
A C
T S
E L E
M E
N T
C
IV
IL
E
N G
IN
E
E R
S Q
U A
D R
O N
A B C D E F G
Sheet of
NUMBER
REFERENCE
SHEET
A
IR
M O
B
IL
IT
Y
C O
M M
A N
D
D E
P A
R T
M E
N T
O F
T H
E A
IR
F
O R
C E
D R
A W
IN
G
N U
M B
E R
P L O
T S
C A
L E
T O
F O
R
/2 -S
IZ
E
P L O
T D
A T
E
C H
K B
Y
D W
N B
Y
D E
S
IG
N E
D B
Y
F
IL
E N
A M
E
D A
T E
S y m b o l
D e s c ri p tio n D a te
A p p ro v e d
S y m b o l
A p p ro v e d
D a te D e s c ri p tio n
D E
C
G J H
G J H
K L M
D E
C
IS
S
U E
D F
O R
B
ID
/C O
N S
T R
U C
T
IO
N
J F
S D
R E
P A
IR
F
IR
E
S U
P P
R E
S S
IO
N
B A
R N
E S
H A
L L D
O R
M
G R
A N
D F
O R
K S
A F
B N
O R
T H
D A
K O
T A
U
UNIT HEATER
UNDERGROUND
UNIT COOLER
UNEXCAVATED
V
VOLT
UNIT VENTILATOR
UTILITY
URINAL
UNFINISHED
UNDERWRITERS LABORATORIES
VITRIFIED CLAY PIPE
VOLUME
VESTIBULE
VENTILATOR
VENTILATION
VAULT DOOR
VERTICAL
VINYL COMPOSTION TILE
WITH
UC
UG
UH
UNEX
UL
UPS
UT
UR
V
VCP
UV
S
SOUTHS
SB
S.A.
S.B.
SCH
SCREW
SCT
SCR
SECT
SJI
S.D.
SDI
SCUT
SCIF
SECTION
INFORMATION FACILITY
SENSITIVE COMPARTMENTED
STEEL DECK INSTITUTE
STEEL JOIST INSTITUTE
STRUCTURAL CLAY TILE
SUBDRAIN
SCUTTLE
SECURITY BARS
SPLASH BLOCK
SCHEDULE
SUPPLY AIR
O
OBSURE
OBSCURE GLASS
OUTSIDE AIR
ON CENTER
OBSCURE WIRE GLASS
OVERHEAD
OFFICE
OPPOSITE
OPENING
OUTSIDE SCREW & YOKE
OPERATIONS
OBSERVATION RISER
OUTSIDE DIAMETER
ON CENTER EACH WAY
O.A.
OBGL
OBSC
OC
OB WG
OD
OH
OFF.
OPP
O.R.
OPS
OS & Y
OPNG
OCEW
V.C.T.
VD
VENT
VENT
VERT
VEST
VOL
SIMILAR
SHEET
SECY
SFU
S.F.
SEQ
SHTG
SHLD.
SIM
SHT.
SQUARE
SP
SPEC
SPF
SPKR
SQ or
SPL
SPH
SOV
STATIC PRESSURE
SPACE HEATER
SPECIFICATIONS
SHUT OFF VALVE
SPECIAL
SPEAKER
SOUNDPROOF
SQUARE FOOTAGE
STRUCTURAL FACING UNIT
SHEATHING
SHOULDER
SEQUENCE
SECRETARY
W/
STATION
STONE
STEEL
S. STL.
SSMR
STC
STA
STGR
STN
STL
STD
SWITCH
STWY
STRUCT
STOR
SW
SWBD
SVF
SUSP
STAIRWAY
STORAGE
STAINLESS STEEL
SOUND TRANSMISSION CLASS
STANDING SEAM METAL ROOFING
STRINGER
STANDARD
SHEET VINYL FLOORING
STRUCTURAL
SWITCHBOARD
SUSPENDED
SUB FLOOR
SQUAD SQUADRON
P
POLE
PARTICLE
PUBLIC ADDRESS
PIONT OF CURVATURE
PUSH BUTTON STATION
PHASE
PLATE
PHARMACY
POLYETHYLENE
PERFORATED
POST INDICATING VALVE
POINT OF INTERSECTION
PIECE
P
PA
PART
PBS
P.C.
P.C.C.
PERF
P.E.
PH or Ø
L
P.I.
P.I.V.
PL or P
PHAR
PC
PLUMBING
PLATFORM
PILING
PORCELAIN
PLYWOOD
POLISH
PANEL
PLASTIC LAMINATE
PAIR
PROJECT
PROCESSING
PRESSED STEEL
PREFINISHED
PREFABRICATED
PARTS PER MILLION
PLBG
PLG
PL
PLATF
PNL
PORC
POL
PLY. WD.
PR
P.P.M.
PREFIN
PREFAB
PROJ
P.S.
PRV
PROC
PLASTERPLAS
PRESSURE REGULATING VALVE
PORTLAND CEMENT CONCRETE
UNFIN
WATER PROOF
WITHOUT
WP
W/O
WPF
T
TREADT
TAN.
TC
TCA
T.E.
TBD
TOGGLE
THICK
TECH
TEMP
TER
TEL
TH
THK
TGL
TERM
TECHNICAL
THRESHOLD
TERMINAL
TERRAZZO
TEMPERATURE
TELEPHONE
TILE COUNCIL OF AMERICA
TOP ELEVATION
TOP OF CURB
TACK BOARD
TANGENT
TOILET
TYPICAL
TOIL
TOPO
TRANS
TV
TYP
T'STAT
TELEVISION
THERMOSTAT
TRANSVERSE
TOPOGRAPHY
T.O. TOP OF
PAVEMENT
PAINTED
PARTITION
TRANSFORMER
POINT OF TANGENCY
POLYVINYL-CHLORIDE
POUNDS/SQUARE INCH
Q
QUART
QUARTERS
PASS WINDOW
QUARTER ROUND
QUARRY TILE
PSI
PT
P.T.
PTD
PTN
PVMT
PVC
PW
QT
QTRS
1/4 RD
Q.T.
RISER
RADIUS
REMOTE CONTROL
RESILIENT BASE
RETURN AIR
RETURN AIR REGISTER
RETURN AIR GRILLE
RECEIVER
ROUND
RIDGE
REFERENCE
RECTIFIER
RECEPTACLE
ROOF DRAIN
RECREATION
R.A.
R or RSR
RAD or R
RB
RAR
RC
R.C.P.
RAG
RD
RCVR
RDGE
R.D.
RECP
RECR
REF
RECT.
R
REINFORCED CONCRETE PIPE
POINT or POTENTIAL (VOLTAGE)
REGISTER
REMOVABLE
ROOFING
REVISIONS
RESILIENT
REQUIRED
REPRODUCTION
REINFORCEMENT
RANGE
ROUGH
RUBBER
ROOM
RAISED FLOOR SYSTEM
RELATIVE HUMIDITY
REG
REM
REINF
REQD
RFG
REV
RESIL.
REPRO
RFS
RGE
RH
RGH
RM
RPM
RPRT
RUB
RAISED PATTERN RUBBER TILE
REVOLUTIONS PER MINUTE
REFRIGERATORREFR
PSF POUNDS/SQUARE FOOT
SYM SYMMETRICAL
ABBREVIATIONS
TOP OF STEELTOS
SK SINK
VFD VARIABLE FREQUENCY DRIVE
PP PAINTED PANEL
PAINT
P RUBBER TILERT
SC SPECIAL COATING
SS SOLID SURFACE
ST STAIN
TT TERRAZZO TILE
VINYL BASEVB
WEATHER PROOF
R (cont.)
W
ROADS
WALKS
CULVERT
77.2
77.2
SD
W
FW
S
FW
WD
OR OR
FM
SD
W
S
FW
FM
FW
WD
PIVPIV
BUILDINGS
CURB & GUTTER
RAILROAD
CONTOURS
STORM DRAIN
DIRECTION OF DRAINAGE
SPOT GRADE ELEVATIONS
SUBDRAIN
FIRE WATER LINE
FORCE MAIN
SANITARY SEWER
WATER LINE
SUBDRAIN OUTLET LINE
OBSERVATION RISER
UTILITY LINE
WASTE DRAIN
SUBDRAIN FLUSHING &
AREA INLET
FIRE HYDRANT
POST INDICATOR VALVE
CURB INLET
DEPENDING ON TYPE OF
OR SERVICE STOP & BOX
FIRE PROTECTION WATER LINE
MANHOLE SELF EXPLANATORY
GATE VALVE & VALVE BOX
NEWEXISTING
CIVIL LEGEND
GENERAL NOTES:
STANDARD NORTH ARROWS
N
N
TRUE
NORTHNORTH
PLAN
METALS
MASONRY
SITE
CONCRETE
STEEL CERAMIC OR QUARRY
(SMALL SCALE)
METAL STUD WALL
(LARGE SCALE)
(LARGE SCALE)
STRUCTURAL STEEL
OTHER
OR BOARD
TERRAZZO
ACOUSTICAL TILE
BRICK PAVERS
CARPET
TILE
LAMINATED WOOD
PROTECTION
THERMAL &
MOISTURE
GLAZING
FINISHES
OR E.J. FILLER
CUT STONE
LIGHTWEIGHT CONC.
COMPRESSIBLE
MASONRY
BRICK OR CLAY TILE
CONCRETE MASONRY
REINFORCEMENT
CEMENT GYPSUM
PRECAST
OR WATERPROFING
(LARGE SCALE)
GYP. BD. OR
(SMALL SCALE)
PLASTER
GLASS
GLASS
INSULATION
INSULATION
BATT OR LOOSE
CAULKING OR SEALANT
FLASHING, DAMPROOFING
ROOF OR RIGID
WOOD
BITUMINOUS PAVEMENT
POURED
GRAVEL OR
CRUSHED ROCK
SAND
DIMENSION LUMBER
FINISH WOOD
PLYWOOD
PARTICLE BOARD
WOOD STUD WALL
REFERENCES
EARTH
ARCHITECTURAL LEGEND
X.X
ROOM LABEL
DETAIL NUMBER
SECTION NUMBER
ELEVATION NUMBER
COLUMN LINE
100DOOR NUMBER
WALL TYPE
FLAG NOTE
ELEVATION LETTER
ELEVATION NUMBER
ELEVATION SYMBOL
FINISH FLOOR
ELEV. = 100'-0"
GRAPHIC SCALE
DRAWING
SCALE
DETAIL SHEET NUMBER
SECTION SHEET
NUMBER
ELEVATION SHEET
NUMBER
ELEVATION SHEET
NUMBER
ROOM NAME AND NUMBER
SCALE: 1/8" = 1'-0"
8' 4' 0 8'
NUMBER OF FEET
1. THESE LEGENDS ARE COMPOSED OF
STANDARD SYMBOLS AND ARE PERTINENT
TO THE CONDITIONS ON THIS SET OF
DRAWINGS TO THE EXTENT APPLICABLE.
2. ADDITIONAL LEGENDS AND/OR ANOTHER
LEGEND SHEET MAY APPEAR IN THIS SET
OF DRAWINGS TO INDICATE SPECIFIC
CONDITIONS IN LIEU OF SYMBOLS SHOWN
ON THIS SHEET. G-003
A B
B R
E V
IA
T
IO
N
S A
N D
L E
G E
N D
LIGHT
G R
A N
D F
O R
K S
A F
B
N D
C O
N T
R A
C T
S E
L E
M E
N T
C
IV
IL
E
N G
IN
E
E R
S Q
U A
D R
O N
A B C D E F G
Sheet of
NUMBER
REFERENCE
SHEET
A
IR
M O
B
IL
IT
Y
C O
M M
A N
D
D E
P A
R T
M E
N T
O F
T H
E A
IR
F
O R
C E
D R
A W
IN
G
N U
M B
E R
P L O
T S
C A
L E
T O
F O
R
/2 -S
IZ
E
P L O
T D
A T
E
C H
K B
Y
D W
N B
Y
D E
S
IG
N E
D B
Y
F
IL
E N
A M
E
D A
T E
S y m b o l
D e s c ri p tio n D a te
A p p ro v e d
S y m b o l
A p p ro v e d
D a te D e s c ri p tio n
D E
C
G J H
G J H
K L M
D E
C
IS
S
U E
D F
O R
B
ID
/C O
N S
T R
U C
T
IO
N
J F
S D
R E
P A
IR
F
IR
E
S U
P P
R E
S S
IO
N
B A
R N
E S
H A
L L D
O R
M
G R
A N
D F
O R
K S
A F
B N
O R
T H
D A
K O
7TH AVE
CONTRACTOR
PARKING AREA
(NO FENCE)
CONTRACTOR
ACCESS
CONTRACTOR
ACCESS
CONTRACTOR
STAGING
AREA
CONSTRUCTION
GATES
CONSTRUCTION
GATES
CONTRACTOR
PARKING AREA
(NO FENCE)
CONTRACTOR SHALL NOT USE THIS
BUILDING ENTRANCE EXCEPT WITH PRIOR
APPROVAL FROM GOVERNMENT
CONSTRUCTION REPRESENTATIVE FOR
SCISSOR LIFT DELIVERY TO PERFORM WORK
SPECIFIED IN UPPER PART OF MAIN LOBBY
DUMPSTER
DUMPSTER
22.00'
MIN.
FH
FH
FH
CONTRACTOR SHALL NOT USE THIS
BUILDING ENTRANCE
STAGING PLAN FLAG NOTES
PROVIDE CONSTRUCTION FENCE AROUND CONSTRUCTION/STAGING
AREA PERIMETER.
G-004
S T
A G
IN
G
P L A
N
STAGING PLAN
N
SCALE: 1" = 40'-0"
40' 20' 0 40'
G R
A N
D F
O R
K S
A F
B
N D
C O
N T
R A
C T
S E
L E
M E
N T
C
IV
IL
E
N G
IN
E
E R
S Q
U A
D R
O N
A B C D E F G
Sheet of
NUMBER
REFERENCE
SHEET
A
IR
M O
B
IL
IT
Y
C O
M M
A N
D
D E
P A
R T
M E
N T
O F
T H
E A
IR
F
O R
C E
D R
A W
IN
G
N U
M B
E R
P L O
T S
C A
L E
T O
F O
R
/2 -S
IZ
E
P L O
T D
A T
E
C H
K B
Y
D W
N B
Y
D E
S
IG
N E
D B
Y
F
IL
E N
A M
E
D A
T E
S y m b o l
D e s c ri p tio n D a te
A p p ro v e d
S y m b o l
A p p ro v e d
D a te D e s c ri p tio n
D E
C
G J H
G J H
K L M
D E
C
IS
S
U E
D F
O R
B
ID
/C O
N S
T R
U C
T
IO
N
J F
S D
R E
P A
IR
F
IR
E
S U
P P
R E
S S
IO
N
B A
R N
E S
H A
L L D
O R
M
G R
A N
D F
O R
K S
A F
B N
O R
T H
D A
K O
EXPOSED
STRUCTURE
EXPOSED
STRUCTURE
EXPOSED
STRUCTURE
EXPOSED
STRUCTURE
EXPOSED
STRUCTURE
EXPOSED
STRUCTURE
OPEN TO ABOVE
OPEN TO ABOVE
GLASS
GLASS
GLASS
UP UP
D
D
W
W
W
W
UP
UP
UP UP
D
D
W
W
W
W
UP
UP
KEY PLAN
AREA
C
AREA BAREA A
KEY PLAN
AREA
C
AREA BAREA A
3 3
CEILING PLAN LEGEND
EXISTING GYPSUM BOARD
CEILING TO REMAIN
EXISTING 2x2 ACOUSTICAL
PANEL CEILING TO REMAIN
LIGHT FIXTURES - SEE
ELECTRICAL
GRILLE AND DIFFUSERS -
SEE MECHANICAL
EXISTING WOOD GRID
SYSTEM TO REMAIN
EXISTING GYPSUM BOARD CEILING
TO BE REMOVED
EXISTING ACOUSTICAL PANEL
CEILING TO BE REMOVED
COMPOSITE DEMOLITION REFLECTED CEILING PLAN - FIRST LEVEL1
N
G R
A N
D F
O R
K S
A F
B
N D
C O
N T
R A
C T
S E
L E
M E
N T
C
IV
IL
E
N G
IN
E
E R
S Q
U A
D R
O N
A B C D E F G
Sheet of
NUMBER
REFERENCE
SHEET
A
IR
M O
B
IL
IT
Y
C O
M M
A N
D
D E
P A
R T
M E
N T
O F
T H
E A
IR
F
O R
C E
D R
A W
IN
G
N U
M B
E R
P L O
T S
C A
L E
T O
F O
R
/2 -S
IZ
E
P L O
T D
A T
E
C H
K B
Y
D W
N B
Y
D E
S
IG
N E
D B
Y
F
IL
E N
A M
E
D A
T E
S y m b o l
D e s c ri p tio n D a te
A p p ro v e d
S y m b o l
A p p ro v e d
D a te D e s c ri p tio n
D E
C
G J H
G J H
K L M
D E
C
IS
S
U E
D F
O R
B
ID
/C O
N S
T R
U C
T
IO
N
J F
S D
R E
P A
IR
F
IR
E
S U
P P
R E
S S
IO
N
B A
R N
E S
H A
L L D
O R
M
G R
A N
D F
O R
K S
A F
B N
O R
T H
D A
K O
T A
SCALE: 1/16" = 1'-0"
16' 8' 0 16'
TYPICAL EXISTING REFLECTED CEILING PLAN2
SCALE: 1/4" = 1'-0"
4' 2' 0 4'
AD111
C O
M P
O S
IT
E
D E
M O
L
IT
IO
N
R E
F L E
C T
E D
C E
IL
IN
G P
L A
N
F
IR
S T
L E
V E
L
EXPOSED
STRUCTURE
EXPOSED
STRUCTURE
EXPOSED
STRUCTURE
OPEN TO ABOVE
OPEN TO ABOVE
GLASS
GLASS
GLASS
UP UP
UP
UP UP
UP
R02 R01
R
R02 R02R02
KEY PLAN
AREA
C
AREA BAREA A
KEY PLAN
AREA
C
AREA BAREA A
CEILING PLAN LEGEND
EXISTING GYPSUM BOARD
CEILING TO REMAIN
EXISTING 2x2 ACOUSTICAL
PANEL CEILING TO REMAIN
LIGHT FIXTURES - SEE
ELECTRICAL
GRILLE AND DIFFUSERS -
SEE MECHANICAL
EXISTING WOOD GRID
SYSTEM TO REMAIN
EXISTING GYPSUM BOARD CEILING
TO BE REMOVED
EXISTING ACOUSTICAL PANEL
CEILING TO BE REMOVED
R01
REFLECTED CELING DEMOLITION PLAN FLAG NOTES
R02
R03
R04
FIRST LEVEL DEMOLITION REFLECTED CEILING PLAN - AREA A1
N
G R
A N
D F
O R
K S
A F
B
N D
C O
N T
R A
C T
S E
L E
M E
N T
C
IV
IL
E
N G
IN
E
E R
S Q
U A
D R
O N
A B C D E F G
Sheet of
NUMBER
REFERENCE
SHEET
A
IR
M O
B
IL
IT
Y
C O
M M
A N
D
D E
P A
R T
M E
N T
O F
T H
E A
IR
F
O R
C E
D R
A W
IN
G
N U
M B
E R
P L O
T S
C A
L E
T O
F O
R
/2 -S
IZ
E
P L O
T D
A T
E
C H
K B
Y
D W
N B
Y
D E
S
IG
N E
D B
Y
F
IL
E N
A M
E
D A
T E
S y m b o l
D e s c ri p tio n D a te
A p p ro v e d
S y m b o l
A p p ro v e d
D a te D e s c ri p tio n
D E
C
G J H
G J H
K L M
D E
C
IS
S
U E
D F
O R
B
ID
/C O
N S
T R
U C
T
IO
N
J F
S D
R E
P A
IR
F
IR
E
S U
P P
R E
S S
IO
N
B A
R N
E S
H A
L L D
O R
M
G R
A N
D F
O R
K S
A F
B N
O R
T H
D A
K O
T A
AD112
F
IR
S T
L E
V E
L D
E M
O L
IT
IO
N R
E F
L E
C T
E D
C E
IL
IN
G P
L A
N
A R
E A
A
SCALE: 1/8" = 1'-0"
8' 4' 0 8'
D
D
W
W
W
W
D
D
W
W
W
W
R01 R02
R
R02
R
KEY PLAN
AREA
C
AREA BAREA A
KEY PLAN
AREA
C
AREA BAREA A
CEILING PLAN LEGEND
EXISTING GYPSUM BOARD
CEILING TO REMAIN
EXISTING 2x2 ACOUSTICAL
PANEL CEILING TO REMAIN
LIGHT FIXTURES - SEE
ELECTRICAL
GRILLE AND DIFFUSERS -
SEE MECHANICAL
EXISTING WOOD GRID
SYSTEM TO REMAIN
EXISTING GYPSUM BOARD CEILING
TO BE REMOVED
EXISTING ACOUSTICAL PANEL
CEILING TO BE REMOVED
R01
REFLECTED CELING DEMOLITION PLAN FLAG NOTES
R02
R03
R04
EXPOSED
STRUCTURE
UPUP
R
R01
R
R
FIRST LEVEL DEMOLITION REFLECTED CEILING PLAN - AREA B1
N
G R
A N
D F
O R
K S
A F
B
N D
C O
N T
R A
C T
S E
L E
M E
N T
C
IV
IL
E
N G
IN
E
E R
S Q
U A
D R
O N
A B C D E F G
Sheet of
NUMBER
REFERENCE
SHEET
A
IR
M O
B
IL
IT
Y
C O
M M
A N
D
D E
P A
R T
M E
N T
O F
T H
E A
IR
F
O R
C E
D R
A W
IN
G
N U
M B
E R
P L O
T S
C A
L E
T O
F O
R
/2 -S
IZ
E
P L O
T D
A T
E
C H
K B
Y
D W
N B
Y
D E
S
IG
N E
D B
Y
F
IL
E N
A M
E
D A
T E
S y m b o l
D e s c ri p tio n D a te
A p p ro v e d
S y m b o l
A p p ro v e d
D a te D e s c ri p tio n
D E
C
G J H
G J H
K L M
D E
C
IS
S
U E
D F
O R
B
ID
/C O
N S
T R
U C
T
IO
N
J F
S D
R E
P A
IR
F
IR
E
S U
P P
R E
S S
IO
N
B A
R N
E S
H A
L L D
O R
M
G R
A N
D F
O R
K S
A F
B N
O R
T H
D A
K O
T A
AD113
F
IR
S T
L E
V E
L D
E M
O L
IT
IO
N R
E F
L E
C T
E D
C E
IL
IN
G P
L A
N
A R
E A
B A
N D
C
SCALE: 1/8" = 1'-0"
8' 4' 0 8'
FIRST LEVEL DEMOLITION REFLECTED CEILING PLAN - AREA C2
N
OPEN TO ABOVE
OPEN TO ABOVE
OPEN
TO
ABOVE
OPEN
TO
ABOVE
EXPOSED
STRUCTURE
W
W
W
W
UP DNDNUP
DN
UP
DNUP
W
W
W
W
UP DNDNUP
DN
UP
DNUP
KEY PLAN
AREA
C
AREA BAREA A
KEY PLAN
AREA
C
AREA BAREA A
CEILING PLAN LEGEND
EXISTING GYPSUM BOARD
CEILING TO REMAIN
EXISTING 2x2 ACOUSTICAL
PANEL CEILING TO REMAIN
LIGHT FIXTURES - SEE
ELECTRICAL
GRILLE AND DIFFUSERS -
SEE MECHANICAL
EXISTING WOOD GRID
SYSTEM TO REMAIN
EXISTING GYPSUM BOARD CEILING
TO BE REMOVED
EXISTING ACOUSTICAL PANEL
CEILING TO BE REMOVED
AD121
C O
M P
O S
IT
E
D E
M O
L
IT
IO
N
R E
F L E
C T
E D
C E
IL
IN
G P
L A
N
S E
C O
N D
L E
V E
L
COMPOSITE DEMOLITION REFLECTED CEILING PLAN - SECOND LEVEL1
N
G R
A N
D F
O R
K S
A F
B
N D
C O
N T
R A
C T
S E
L E
M E
N T
C
IV
IL
E
N G
IN
E
E R
S Q
U A
D R
O N
A B C D E F G
Sheet of
NUMBER
REFERENCE
SHEET
A
IR
M O
B
IL
IT
Y
C O
M M
A N
D
D E
P A
R T
M E
N T
O F
T H
E A
IR
F
O R
C E
D R
A W
IN
G
N U
M B
E R
P L O
T S
C A
L E
T O
F O
R
/2 -S
IZ
E
P L O
T D
A T
E
C H
K B
Y
D W
N B
Y
D E
S
IG
N E
D B
Y
F
IL
E N
A M
E
D A
T E
S y m b o l
D e s c ri p tio n D a te
A p p ro v e d
S y m b o l
A p p ro v e d
D a te D e s c ri p tio n
D E
C
G J H
G J H
K L M
D E
C
IS
S
U E
D F
O R
B
ID
/C O
N S
T R
U C
T
IO
N
J F
S D
R E
P A
IR
F
IR
E
S U
P P
R E
S S
IO
N
B A
R N
E S
H A
L L D
O R
M
G R
A N
D F
O R
K S
A F
B N
O R
T H
D A
K O
T A
SCALE: 1/16" = 1'-0"
16' 8' 0 16'
OPEN TO ABOVE
OPEN TO ABOVE
OPEN
TO
ABOVE
OPEN
TO
ABOVE
UP DNDNUP
DNUP
UP DNDNUP
DNUP
R02 R02 R02R01R02 R02 R02 R02 R02R02
KEY PLAN
AREA
C
AREA BAREA A
KEY PLAN
AREA
C
AREA BAREA A
CEILING PLAN LEGEND
EXISTING GYPSUM BOARD
CEILING TO REMAIN
EXISTING 2x2 ACOUSTICAL
PANEL CEILING TO REMAIN
LIGHT FIXTURES - SEE
ELECTRICAL
GRILLE AND DIFFUSERS -
SEE MECHANICAL
EXISTING WOOD GRID
SYSTEM TO REMAIN
EXISTING GYPSUM BOARD CEILING
TO BE REMOVED
EXISTING ACOUSTICAL PANEL
CEILING TO BE REMOVED
R01
REFLECTED CELING DEMOLITION PLAN FLAG NOTES
R02
R03
R04
AD122
S E
C O
N D
L E
V E
L D
E M
O L
IT
IO
N
R E
F L E
C T
E D
C E
IL
IN
G P
L A
N
A R
E A
A
SECOND LEVEL DEMOLITION REFLECTED CEILING PLAN - AREA A1
N
G R
A N
D F
O R
K S
A F
B
N D
C O
N T
R A
C T
S E
L E
M E
N T
C
IV
IL
E
N G
IN
E
E R
S Q
U A
D R
O N
A B C D E F G
Sheet of
NUMBER
REFERENCE
SHEET
A
IR
M O
B
IL
IT
Y
C O
M M
A N
D
D E
P A
R T
M E
N T
O F
T H
E A
IR
F
O R
C E
D R
A W
IN
G
N U
M B
E R
P L O
T S
C A
L E
T O
F O
R
/2 -S
IZ
E
P L O
T D
A T
E
C H
K B
Y
D W
N B
Y
D E
S
IG
N E
D B
Y
F
IL
E N
A M
E
D A
T E
S y m b o l
D e s c ri p tio n D a te
A p p ro v e d
S y m b o l
A p p ro v e d
D a te D e s c ri p tio n
D E
C
G J H
G J H
K L M
D E
C
IS
S
U E
D F
O R
B
ID
/C O
N S
T R
U C
T
IO
N
J F
S D
R E
P A
IR
F
IR
E
S U
P P
R E
S S
IO
N
B A
R N
E S
H A
L L D
O R
M
G R
A N
D F
O R
K S
A F
B N
O R
T H
D A
K O
T A
OPEN
TO
ABOVE
EXPOSED
STRUCTURE
W
W
W
W
UP
W
W
W
W
UP
R02
R02
R01
R01
R02
R02
R02
KEY PLAN
AREA
C
AREA BAREA A
KEY PLAN
AREA
C
AREA BAREA A
CEILING PLAN LEGEND
EXISTING GYPSUM BOARD
CEILING TO REMAIN
EXISTING 2x2 ACOUSTICAL
PANEL CEILING TO REMAIN
LIGHT FIXTURES - SEE
ELECTRICAL
GRILLE AND DIFFUSERS -
SEE MECHANICAL
EXISTING WOOD GRID
SYSTEM TO REMAIN
EXISTING GYPSUM BOARD CEILING
TO BE REMOVED
EXISTING ACOUSTICAL PANEL
CEILING TO BE REMOVED
R01
REFLECTED CELING DEMOLITION PLAN FLAG NOTES
R02
R03
R04
DN
UP
DN
UP
R01
R02
R02
R02
AD123
S E
C O
N D
L E
V E
L D
E M
O L
IT
IO
N
R E
F L E
C T
E D
C E
IL
IN
G P
L A
N
A R
E A
B A
N D
C
SECOND LEVEL DEMOLITION REFLECTED CEILING PLAN - AREA B1
N
G R
A N
D F
O R
K S
A F
B
N D
C O
N T
R A
C T
S E
L E
M E
N T
C
IV
IL
E
N G
IN
E
E R
S Q
U A
D R
O N
A B C D E F G
Sheet of
NUMBER
REFERENCE
SHEET
A
IR
M O
B
IL
IT
Y
C O
M M
A N
D
D E
P A
R T
M E
N T
O F
T H
E A
IR
F
O R
C E
D R
A W
IN
G
N U
M B
E R
P L O
T S
C A
L E
T O
F O
R
/2 -S
IZ
E
P L O
T D
A T
E
C H
K B
Y
D W
N B
Y
D E
S
IG
N E
D B
Y
F
IL
E N
A M
E
D A
T E
S y m b o l
D e s c ri p tio n D a te
A p p ro v e d
S y m b o l
A p p ro v e d
D a te D e s c ri p tio n
D E
C
G J H
G J H
K L M
D E
C
IS
S
U E
D F
O R
B
ID
/C O
N S
T R
U C
T
IO
N
J F
S D
R E
P A
IR
F
IR
E
S U
P P
R E
S S
IO
N
B A
R N
E S
H A
L L D
O R
M
G R
A N
D F
O R
K S
A F
B N
O R
T H
D A
K O
T A
SCALE: 1/8" = 1'-0"
8' 4' 0 8'
SECOND LEVEL DEMOLITION REFLECTED CEILING PLAN - AREA C2
N
METAL LINEAR CEILING
EL. = 133'-6"
METAL LINEAR CEILING
EL. = 133'-6"
T.O. ARCH MTL. LINEAR CEILING
EL. = 136'-10 1/2 "
OUTLINE OF
ROOF
OVERHANG
EXPOSED
STRUCTURE
EXPOSED
STRUCTURE
EXPOSED
STRUCTURE
CEILING AREA; NO ACCESS
CEILING AREA; NO ACCESS
W
W
W
W
DN
DN DN
DN
W
W
W
W
DN
DN DN
DN
KEY PLAN
AREA
C
AREA BAREA A
KEY PLAN
AREA
C
AREA BAREA A
CEILING PLAN LEGEND
EXISTING GYPSUM BOARD
CEILING TO REMAIN
EXISTING 2x2 ACOUSTICAL
PANEL CEILING TO REMAIN
LIGHT FIXTURES - SEE
ELECTRICAL
GRILLE AND DIFFUSERS -
SEE MECHANICAL
EXISTING WOOD GRID
SYSTEM TO REMAIN
EXISTING GYPSUM BOARD CEILING
TO BE REMOVED
EXISTING ACOUSTICAL PANEL
CEILING TO BE REMOVED
AD131
C O
M P
O S
IT
E
D E
M O
L
IT
IO
N
R E
F L E
C T
E D
C E
IL
IN
G P
L A
N
T H
IR
D
L E
V E
L
COMPOSITE DEMOLITION REFLECTED CEILING PLAN - THIRD LEVEL1
N
G R
A N
D F
O R
K S
A F
B
N D
C O
N T
R A
C T
S E
L E
M E
N T
C
IV
IL
E
N G
IN
E
E R
S Q
U A
D R
O N
A B C D E F G
Sheet of
NUMBER
REFERENCE
SHEET
A
IR
M O
B
IL
IT
Y
C O
M M
A N
D
D E
P A
R T
M E
N T
O F
T H
E A
IR
F
O R
C E
D R
A W
IN
G
N U
M B
E R
P L O
T S
C A
L E
T O
F O
R
/2 -S
IZ
E
P L O
T D
A T
E
C H
K B
Y
D W
N B
Y
D E
S
IG
N E
D B
Y
F
IL
E N
A M
E
D A
T E
S y m b o l
D e s c ri p tio n D a te
A p p ro v e d
S y m b o l
A p p ro v e d
D a te D e s c ri p tio n
D E
C
G J H
G J H
K L M
D E
C
IS
S
U E
D F
O R
B
ID
/C O
N S
T R
U C
T
IO
N
J F
S D
R E
P A
IR
F
IR
E
S U
P P
R E
S S
IO
N
B A
R N
E S
H A
L L D
O R
M
G R
A N
D F
O R
K S
A F
B N
O R
T H
D A
K O
T A
SCALE: 1/16" = 1'-0"
16' 8' 0 16'
T.O. ARCH MTL. LINEAR CEILING
EL. = 136'-10 1/2 "
EXPOSED
STRUCTURE
CEILING AREA; NO ACCESS
DN DN
DN
DN DN
DN
R02R01
R02 R03
R04
R04
R04
R02 R02 R02
KEY PLAN
AREA
C
AREA BAREA A
KEY PLAN
AREA
C
AREA BAREA A
CEILING PLAN LEGEND
EXISTING GYPSUM BOARD
CEILING TO REMAIN
EXISTING 2x2 ACOUSTICAL
PANEL CEILING TO REMAIN
LIGHT FIXTURES - SEE
ELECTRICAL
GRILLE AND DIFFUSERS -
SEE MECHANICAL
EXISTING WOOD GRID
SYSTEM TO REMAIN
EXISTING GYPSUM BOARD CEILING
TO BE REMOVED
EXISTING ACOUSTICAL PANEL
CEILING TO BE REMOVED
R01
REFLECTED CELING DEMOLITION PLAN FLAG NOTES
R02
R03
R04
AD132
T H
IR
D
L E
V E
L D
E M
O L
IT
IO
N
R E
F L E
C T
E D
C E
IL
IN
G P
L A
N
A R
E A
A
THIRD LEVEL DEMOLITION REFLECTED CEILING PLAN - AREA A1
N
G R
A N
D F
O R
K S
A F
B
N D
C O
N T
R A
C T
S E
L E
M E
N T
C
IV
IL
E
N G
IN
E
E R
S Q
U A
D R
O N
A B C D E F G
Sheet of
NUMBER
REFERENCE
SHEET
A
IR
M O
B
IL
IT
Y
C O
M M
A N
D
D E
P A
R T
M E
N T
O F
T H
E A
IR
F
O R
C E
D R
A W
IN
G
N U
M B
E R
P L O
T S
C A
L E
T O
F O
R
/2 -S
IZ
E
P L O
T D
A T
E
C H
K B
Y
D W
N B
Y
D E
S
IG
N E
D B
Y
F
IL
E N
A M
E
D A
T E
S y m b o l
D e s c ri p tio n D a te
A p p ro v e d
S y m b o l
A p p ro v e d
D a te D e s c ri p tio n
D E
C
G J H
G J H
K L M
D E
C
IS
S
U E
D F
O R
B
ID
/C O
N S
T R
U C
T
IO
N
J F
S D
R E
P A
IR
F
IR
E
S U
P P
R E
S S
IO
N
B A
R N
E S
H A
L L D
O R
M
G R
A N
D F
O R
K S
A F
B N
O R
T H
D A
K O
T A
OVERHANG
EXPOSED
STRUCTURE
EXPOSED
STRUCTURE
CEILING AREA; NO ACCESS
W
W
W
W
W
W
W
W
R
R02
R01
R02 R02
R02
KEY PLAN
AREA
C
AREA BAREA A
KEY PLAN
AREA
C
AREA BAREA A
CEILING PLAN LEGEND
EXISTING GYPSUM BOARD
CEILING TO REMAIN
EXISTING 2x2 ACOUSTICAL
PANEL CEILING TO REMAIN
LIGHT FIXTURES - SEE
ELECTRICAL
GRILLE AND DIFFUSERS -
SEE MECHANICAL
EXISTING WOOD GRID
SYSTEM TO REMAIN
EXISTING GYPSUM BOARD CEILING
TO BE REMOVED
EXISTING ACOUSTICAL PANEL
CEILING TO BE REMOVED
R01
REFLECTED CELING DEMOLITION PLAN FLAG NOTES
R02
R03
R04
OUTLINE OF
ROOF
OVERHANG
DN DN
R01
R
R04
R
AD133
T H
IR
D
L E
V E
L D
E M
O L
IT
IO
N
R E
F L E
C T
E D
C E
IL
IN
G P
L A
N
A R
E A
B A
N D
C
THIRD LEVEL DEMOLITION REFLECTED CEILING PLAN - AREA B1
N
G R
A N
D F
O R
K S
A F
B
N D
C O
N T
R A
C T
S E
L E
M E
N T
C
IV
IL
E
N G
IN
E
E R
S Q
U A
D R
O N
A B C D E F G
Sheet of
NUMBER
REFERENCE
SHEET
A
IR
M O
B
IL
IT
Y
C O
M M
A N
D
D E
P A
R T
M E
N T
O F
T H
E A
IR
F
O R
C E
D R
A W
IN
G
N U
M B
E R
P L O
T S
C A
L E
T O
F O
R
/2 -S
IZ
E
P L O
T D
A T
E
C H
K B
Y
D W
N B
Y
D E
S
IG
N E
D B
Y
F
IL
E N
A M
E
D A
T E
S y m b o l
D e s c ri p tio n D a te
A p p ro v e d
S y m b o l
A p p ro v e d
D a te D e s c ri p tio n
D E
C
G J H
G J H
K L M
D E
C
IS
S
U E
D F
O R
B
ID
/C O
N S
T R
U C
T
IO
N
J F
S D
R E
P A
IR
F
IR
E
S U
P P
R E
S S
IO
N
B A
R N
E S
H A
L L D
O R
M
G R
A N
D F
O R
K S
A F
B N
O R
T H
D A
K O
T A
SCALE: 1/8" = 1'-0"
8' 4' 0 8'
THIRD LEVEL DEMOLITION REFLECTED CEILING PLAN - AREA C2
N
EXPOSED
STRUCTURE
EXPOSED
STRUCTURE
EXPOSED
STRUCTURE
EXPOSED
STRUCTURE
EXPOSED
STRUCTURE
OPEN TO ABOVE
OPEN TO ABOVE
GLASS
GLASS
GLASS
UP UP
D
D
W
W
W
W
UP
UP
UP UP
D
D
W
W
W
W
UP
UP
KEY PLAN
AREA
C
AREA BAREA A
KEY PLAN
AREA
C
AREA BAREA A
3 3
CEILING PLAN LEGEND
EXISTING GYPSUM BOARD
CEILING TO REMAIN
EXISTING 2x2 ACOUSTICAL
PANEL CEILING TO REMAIN
LIGHT FIXTURES - SEE
ELECTRICAL
GRILLE AND DIFFUSERS -
SEE MECHANICAL
EXISTING WOOD GRID
SYSTEM TO REMAIN
GYPSUM BOARD CEILING
ACOUSTICAL PANEL CEILING
REFLECTED CELING PLAN GENERAL NOTES
COMPOSITE REFLECTED CEILING PLAN - FIRST LEVEL1
N
G R
A N
D F
O R
K S
A F
B
N D
C O
N T
R A
C T
S E
L E
M E
N T
C
IV
IL
E
N G
IN
E
E R
S Q
U A
D R
O N
A B C D E F G
Sheet of
NUMBER
REFERENCE
SHEET
A
IR
M O
B
IL
IT
Y
C O
M M
A N
D
D E
P A
R T
M E
N T
O F
T H
E A
IR
F
O R
C E
D R
A W
IN
G
N U
M B
E R
P L O
T S
C A
L E
T O
F O
R
/2 -S
IZ
E
P L O
T D
A T
E
C H
K B
Y
D W
N B
Y
D E
S
IG
N E
D B
Y
F
IL
E N
A M
E
D A
T E
S y m b o l
D e s c ri p tio n D a te
A p p ro v e d
S y m b o l
A p p ro v e d
D a te D e s c ri p tio n
D E
C
G J H
G J H
K L M
D E
C
IS
S
U E
D F
O R
B
ID
/C O
N S
T R
U C
T
IO
N
J F
S D
R E
P A
IR
F
IR
E
S U
P P
R E
S S
IO
N
B A
R N
E S
H A
L L D
O R
M
G R
A N
D F
O R
K S
A F
B N
O R
T H
D A
K O
T A
SCALE: 1/16" = 1'-0"
16' 8' 0 16'
TYPICAL EXISTING REFLECTED CEILING PLAN2
SCALE: 1/4" = 1'-0"
4' 2' 0 4'
TYPICAL SECTION THRU DORM ENTRY3
SCALE: 1-1/2" = 1'-0"
1' 6" 0 1'
A-111
C O
M P
O S
IT
E
R E
F L E
C T
E D
C E
IL
IN
G P
L A
N
F
IR
S T
L E
V E
L
NOTE 3
STAIR
STAIR NOTE 3
CORRIDOR NOTE 3
CORRIDOR NOTE 3
CORRIDOR NOTE 3
GAME ROOM NOTE 3
LOBBY NOTE 3
ROOM FINISH SCHEDULE LEGEND
NOTE: REFER TO COLOR SCHEDULE FOR ALL INTERIOR FINISHES.
ROOM FINISH SCHEDULE NOTES
EXPOSED
STRUCTURE
EXPOSED
STRUCTURE
EXPOSED
STRUCTURE
OPEN TO ABOVE
OPEN TO ABOVE
GLASS
GLASS
GLASS
UP UP
UP
UP UP
UP
C04 C02 C03
KEY PLAN
AREA
C
AREA BAREA A
KEY PLAN
AREA
C
AREA BAREA A
CEILING PLAN LEGEND
EXISTING GYPSUM BOARD
CEILING TO REMAIN
EXISTING 2x2 ACOUSTICAL
PANEL CEILING TO REMAIN
LIGHT FIXTURES - SEE
ELECTRICAL
GRILLE AND DIFFUSERS -
SEE MECHANICAL
EXISTING WOOD GRID
SYSTEM TO REMAIN
GYPSUM BOARD CEILING
ACOUSTICAL PANEL CEILING
C01
REFLECTED CELING PLAN FLAG NOTES
C02
C03
C04
C05
REFLECTED CELING PLAN GENERAL NOTES
FIRST LEVEL REFLECTED CEILING PLAN - AREA A1
N
G R
A N
D F
O R
K S
A F
B
N D
C O
N T
R A
C T
S E
L E
M E
N T
C
IV
IL
E
N G
IN
E
E R
S Q
U A
D R
O N
A B C D E F G
Sheet of
NUMBER
REFERENCE
SHEET
A
IR
M O
B
IL
IT
Y
C O
M M
A N
D
D E
P A
R T
M E
N T
O F
T H
E A
IR
F
O R
C E
D R
A W
IN
G
N U
M B
E R
P L O
T S
C A
L E
T O
F O
R
/2 -S
IZ
E
P L O
T D
A T
E
C H
K B
Y
D W
N B
Y
D E
S
IG
N E
D B
Y
F
IL
E N
A M
E
D A
T E
S y m b o l
D e s c ri p tio n D a te
A p p ro v e d
S y m b o l
A p p ro v e d
D a te D e s c ri p tio n
D E
C
G J H
G J H
K L M
D E
C
IS
S
U E
D F
O R
B
ID
/C O
N S
T R
U C
T
IO
N
J F
S D
R E
P A
IR
F
IR
E
S U
P P
R E
S S
IO
N
B A
R N
E S
H A
L L D
O R
M
G R
A N
D F
O R
K S
A F
B N
O R
T H
D A
K O
T A
A-112
F
IR
S T
L E
V E
L R
E F
L E
C T
E D
C E
IL
IN
G P
L A
N
A R
E A
A
STRUCTUREUP
D
D
W
W
W
W
UP
D
D
W
W
W
W
C02
KEY PLAN
AREA
C
AREA BAREA A
KEY PLAN
AREA
C
AREA BAREA A
CEILING PLAN LEGEND
EXISTING GYPSUM BOARD
CEILING TO REMAIN
EXISTING 2x2 ACOUSTICAL
PANEL CEILING TO REMAIN
LIGHT FIXTURES - SEE
ELECTRICAL
GRILLE AND DIFFUSERS -
SEE MECHANICAL
EXISTING WOOD GRID
SYSTEM TO REMAIN
GYPSUM BOARD CEILING
ACOUSTICAL PANEL CEILING
EXPOSED
STRUCTURE
UPUP
C02
C01
REFLECTED CELING PLAN FLAG NOTES
C02
C03
C04
C05 REFLECTED CELING PLAN GENERAL NOTES
FIRST LEVEL REFLECTED CEILING PLAN - AREA B1
N
G R
A N
D F
O R
K S
A F
B
N D
C O
N T
R A
C T
S E
L E
M E
N T
C
IV
IL
E
N G
IN
E
E R
S Q
U A
D R
O N
A B C D E F G
Sheet of
NUMBER
REFERENCE
SHEET
A
IR
M O
B
IL
IT
Y
C O
M M
A N
D
D E
P A
R T
M E
N T
O F
T H
E A
IR
F
O R
C E
D R
A W
IN
G
N U
M B
E R
P L O
T S
C A
L E
T O
F O
R
/2 -S
IZ
E
P L O
T D
A T
E
C H
K B
Y
D W
N B
Y
D E
S
IG
N E
D B
Y
F
IL
E N
A M
E
D A
T E
S y m b o l
D e s c ri p tio n D a te
A p p ro v e d
S y m b o l
A p p ro v e d
D a te D e s c ri p tio n
D E
C
G J H
G J H
K L M
D E
C
IS
S
U E
D F
O R
B
ID
/C O
N S
T R
U C
T
IO
N
J F
S D
R E
P A
IR
F
IR
E
S U
P P
R E
S S
IO
N
B A
R N
E S
H A
L L D
O R
M
G R
A N
D F
O R
K S
A F
B N
O R
T H
D A
K O
T A
A-113
F
IR
S T
L E
V E
L R
E F
L E
C T
E D
C E
IL
IN
G P
L A
N
A R
E A
B A
N D
C
SCALE: 1/8" = 1'-0"
8' 4' 0 8'
FIRST LEVEL REFLECTED CEILING PLAN - AREA C2
N
OPEN TO ABOVE
OPEN TO ABOVE
OPEN
TO
ABOVE
OPEN
TO
ABOVE
EXPOSED
STRUCTURE
W
W
W
W
UP DNDNUP
DN
UP
DNUP
W
W
W
W
UP DNDNUP
DN
UP
DNUP
KEY PLAN
AREA
C
AREA BAREA A
KEY PLAN
AREA
C
AREA BAREA A
CEILING PLAN LEGEND
EXISTING GYPSUM BOARD
CEILING TO REMAIN
EXISTING 2x2 ACOUSTICAL
PANEL CEILING TO REMAIN
LIGHT FIXTURES - SEE
ELECTRICAL
GRILLE AND DIFFUSERS -
SEE MECHANICAL
EXISTING WOOD GRID
SYSTEM TO REMAIN
GYPSUM BOARD CEILING
ACOUSTICAL PANEL CEILING
REFLECTED CELING PLAN GENERAL NOTES
COMPOSITE REFLECTED CEILING PLAN - SECOND LEVEL1
N
G R
A N
D F
O R
K S
A F
B
N D
C O
N T
R A
C T
S E
L E
M E
N T
C
IV
IL
E
N G
IN
E
E R
S Q
U A
D R
O N
A B C D E F G
Sheet of
NUMBER
REFERENCE
SHEET
A
IR
M O
B
IL
IT
Y
C O
M M
A N
D
D E
P A
R T
M E
N T
O F
T H
E A
IR
F
O R
C E
D R
A W
IN
G
N U
M B
E R
P L O
T S
C A
L E
T O
F O
R
/2 -S
IZ
E
P L O
T D
A T
E
C H
K B
Y
D W
N B
Y
D E
S
IG
N E
D B
Y
F
IL
E N
A M
E
D A
T E
S y m b o l
D e s c ri p tio n D a te
A p p ro v e d
S y m b o l
A p p ro v e d
D a te D e s c ri p tio n
D E
C
G J H
G J H
K L M
D E
C
IS
S
U E
D F
O R
B
ID
/C O
N S
T R
U C
T
IO
N
J F
S D
R E
P A
IR
F
IR
E
S U
P P
R E
S S
IO
N
B A
R N
E S
H A
L L D
O R
M
G R
A N
D F
O R
K S
A F
B N
O R
T H
D A
K O
T A
SCALE: 1/16" = 1'-0"
16' 8' 0 16'
ROOM FINISH SCHEDULE LEGEND
NOTE: REFER TO COLOR SCHEDULE FOR ALL INTERIOR FINISHES.
ROOM FINISH SCHEDULE NOTES
STAIR
STAIR P-1
CORRIDOR BRIDGE
CORRIDOR EX GWB
CORRIDOR
CORRIDOR
A-121
C O
M P
O S
IT
E
R E
F L E
C T
E D
C E
IL
IN
G P
L A
N
S E
C O
N D
L E
V E
L
OPEN TO ABOVE
OPEN TO ABOVE
OPEN
TO
ABOVE
OPEN
TO
ABOVE
UP DNDNUP
DNUP
UP DNDNUP
DNUP
C04 C02
KEY PLAN
AREA
C
AREA BAREA A
KEY PLAN
AREA
C
AREA BAREA A
CEILING PLAN LEGEND
EXISTING GYPSUM BOARD
CEILING TO REMAIN
EXISTING 2x2 ACOUSTICAL
PANEL CEILING TO REMAIN
LIGHT FIXTURES - SEE
ELECTRICAL
GRILLE AND DIFFUSERS -
SEE MECHANICAL
EXISTING WOOD GRID
SYSTEM TO REMAIN
GYPSUM BOARD CEILING
ACOUSTICAL PANEL CEILING
C01
REFLECTED CELING PLAN FLAG NOTES
C02
C03
C04
C05
REFLECTED CELING PLAN GENERAL NOTES
SECOND LEVEL REFLECTED CEILING PLAN -AREA A1
N
G R
A N
D F
O R
K S
A F
B
N D
C O
N T
R A
C T
S E
L E
M E
N T
C
IV
IL
E
N G
IN
E
E R
S Q
U A
D R
O N
A B C D E F G
Sheet of
NUMBER
REFERENCE
SHEET
A
IR
M O
B
IL
IT
Y
C O
M M
A N
D
D E
P A
R T
M E
N T
O F
T H
E A
IR
F
O R
C E
D R
A W
IN
G
N U
M B
E R
P L O
T S
C A
L E
T O
F O
R
/2 -S
IZ
E
P L O
T D
A T
E
C H
K B
Y
D W
N B
Y
D E
S
IG
N E
D B
Y
F
IL
E N
A M
E
D A
T E
S y m b o l
D e s c ri p tio n D a te
A p p ro v e d
S y m b o l
A p p ro v e d
D a te D e s c ri p tio n
D E
C
G J H
G J H
K L M
D E
C
IS
S
U E
D F
O R
B
ID
/C O
N S
T R
U C
T
IO
N
J F
S D
R E
P A
IR
F
IR
E
S U
P P
R E
S S
IO
N
B A
R N
E S
H A
L L D
O R
M
G R
A N
D F
O R
K S
A F
B N
O R
T H
D A
K O
T A
A-122
S E
C O
N D
L E
V E
L R
E F
L E
C T
E D
C E
IL
IN
G P
L A
N
A R
E A
A
KEY PLAN
AREA
C
AREA BAREA A
KEY PLAN
AREA
C
AREA BAREA A
CEILING PLAN LEGEND
EXISTING GYPSUM BOARD
CEILING TO REMAIN
EXISTING 2x2 ACOUSTICAL
PANEL CEILING TO REMAIN
LIGHT FIXTURES - SEE
ELECTRICAL
GRILLE AND DIFFUSERS -
SEE MECHANICAL
EXISTING WOOD GRID
SYSTEM TO REMAIN
GYPSUM BOARD CEILING
ACOUSTICAL PANEL CEILING
OPEN
TO
ABOVE
EXPOSED
STRUCTURE
W
W
W
W
UP
W
W
W
W
UP
C02
DN
UP
DN
UP
C02
C01
REFLECTED CELING PLAN FLAG NOTES
C02
C03
C04
C05 REFLECTED CELING PLAN GENERAL NOTES
SECOND LEVEL REFLECTED CEILING PLAN -AREA C2
N
G R
A N
D F
O R
K S
A F
B
N D
C O
N T
R A
C T
S E
L E
M E
N T
C
IV
IL
E
N G
IN
E
E R
S Q
U A
D R
O N
A B C D E F G
Sheet of
NUMBER
REFERENCE
SHEET
A
IR
M O
B
IL
IT
Y
C O
M M
A N
D
D E
P A
R T
M E
N T
O F
T H
E A
IR
F
O R
C E
D R
A W
IN
G
N U
M B
E R
P L O
T S
C A
L E
T O
F O
R
/2 -S
IZ
E
P L O
T D
A T
E
C H
K B
Y
D W
N B
Y
D E
S
IG
N E
D B
Y
F
IL
E N
A M
E
D A
T E
S y m b o l
D e s c ri p tio n D a te
A p p ro v e d
S y m b o l
A p p ro v e d
D a te D e s c ri p tio n
D E
C
G J H
G J H
K L M
D E
C
IS
S
U E
D F
O R
B
ID
/C O
N S
T R
U C
T
IO
N
J F
S D
R E
P A
IR
F
IR
E
S U
P P
R E
S S
IO
N
B A
R N
E S
H A
L L D
O R
M
G R
A N
D F
O R
K S
A F
B N
O R
T H
D A
K O
T A
A-123
S E
C O
N D
L E
V E
L R
E F
L E
C T
E D
C E
IL
IN
G P
L A
N
A R
E A
B A
N D
C
SCALE: 1/8" = 1'-0"
8' 4' 0 8'
SECOND LEVEL REFLECTED CEILING PLAN -AREA B1
N
METAL LINEAR CEILING
EL. = 133'-6"
T.O. ARCH MTL. LINEAR CEILING
EL. = 136'-10 1/2 "
OUTLINE OF
ROOF
OVERHANG
EXPOSED
STRUCTURE
EXPOSED
STRUCTURE
EXPOSED
STRUCTURE
CEILING AREA; NO ACCESS
CEILING AREA; NO ACCESS
W
W
W
W
DN
DN DN
DN
W
W
W
W
DN
DN DN
DN
KEY PLAN
AREA
C
AREA BAREA A
KEY PLAN
AREA
C
AREA BAREA A
CEILING PLAN LEGEND
EXISTING GYPSUM BOARD
CEILING TO REMAIN
EXISTING 2x2 ACOUSTICAL
PANEL CEILING TO REMAIN
LIGHT FIXTURES - SEE
ELECTRICAL
GRILLE AND DIFFUSERS -
SEE MECHANICAL
EXISTING WOOD GRID
SYSTEM TO REMAIN
GYPSUM BOARD CEILING
ACOUSTICAL PANEL CEILING
REFLECTED CELING PLAN GENERAL NOTES
COMPOSITE REFLECTED CEILING PLAN - THIRD LEVEL1
N
G R
A N
D F
O R
K S
A F
B
N D
C O
N T
R A
C T
S E
L E
M E
N T
C
IV
IL
E
N G
IN
E
E R
S Q
U A
D R
O N
A B C D E F G
Sheet of
NUMBER
REFERENCE
SHEET
A
IR
M O
B
IL
IT
Y
C O
M M
A N
D
D E
P A
R T
M E
N T
O F
T H
E A
IR
F
O R
C E
D R
A W
IN
G
N U
M B
E R
P L O
T S
C A
L E
T O
F O
R
/2 -S
IZ
E
P L O
T D
A T
E
C H
K B
Y
D W
N B
Y
D E
S
IG
N E
D B
Y
F
IL
E N
A M
E
D A
T E
S y m b o l
D e s c ri p tio n D a te
A p p ro v e d
S y m b o l
A p p ro v e d
D a te D e s c ri p tio n
D E
C
G J H
G J H
K L M
D E
C
IS
S
U E
D F
O R
B
ID
/C O
N S
T R
U C
T
IO
N
J F
S D
R E
P A
IR
F
IR
E
S U
P P
R E
S S
IO
N
B A
R N
E S
H A
L L D
O R
M
G R
A N
D F
O R
K S
A F
B N
O R
T H
D A
K O
T A
SCALE: 1/16" = 1'-0"
16' 8' 0 16'
NOTE 4
NOTE 4
STAIR NOTE 4
STAIR NOTE 4
CORRIDOR BRIDGE NOTE 5
CORRIDOR NOTE 3
CORRIDOR NOTE 3
CORRIDOR NOTE 3
A-131
C O
M P
O S
IT
E
R E
F L E
C T
E D
C E
IL
IN
G P
L A
N
T H
IR
D
L E
V E
L
ROOM FINISH SCHEDULE LEGEND
NOTE: REFER TO COLOR SCHEDULE FOR ALL INTERIOR FINISHES.
ROOM FINISH SCHEDULE NOTES
T.O. ARCH MTL. LINEAR CEILING
EL. = 136'-10 1/2 "
EXPOSED
STRUCTURE
CEILING AREA; NO ACCESS
DN DN
DN
DN DN
DN
C01
C05
C04 C02
C05
C05
KEY PLAN
AREA
C
AREA BAREA A
KEY PLAN
AREA
C
AREA BAREA A
CEILING PLAN LEGEND
EXISTING GYPSUM BOARD
CEILING TO REMAIN
EXISTING 2x2 ACOUSTICAL
PANEL CEILING TO REMAIN
LIGHT FIXTURES - SEE
ELECTRICAL
GRILLE AND DIFFUSERS -
SEE MECHANICAL
EXISTING WOOD GRID
SYSTEM TO REMAIN
GYPSUM BOARD CEILING
ACOUSTICAL PANEL CEILING
C01
REFLECTED CELING PLAN FLAG NOTES
C02
C03
C04
C05 REFLECTED CELING PLAN GENERAL NOTES
THIRD LEVEL REFLECTED CEILING PLAN - AREA A1
N
G R
A N
D F
O R
K S
A F
B
N D
C O
N T
R A
C T
S E
L E
M E
N T
C
IV
IL
E
N G
IN
E
E R
S Q
U A
D R
O N
A B C D E F G
Sheet of
NUMBER
REFERENCE
SHEET
A
IR
M O
B
IL
IT
Y
C O
M M
A N
D
D E
P A
R T
M E
N T
O F
T H
E A
IR
F
O R
C E
D R
A W
IN
G
N U
M B
E R
P L O
T S
C A
L E
T O
F O
R
/2 -S
IZ
E
P L O
T D
A T
E
C H
K B
Y
D W
N B
Y
D E
S
IG
N E
D B
Y
F
IL
E N
A M
E
D A
T E
S y m b o l
D e s c ri p tio n D a te
A p p ro v e d
S y m b o l
A p p ro v e d
D a te D e s c ri p tio n
D E
C
G J H
G J H
K L M
D E
C
IS
S
U E
D F
O R
B
ID
/C O
N S
T R
U C
T
IO
N
J F
S D
R E
P A
IR
F
IR
E
S U
P P
R E
S S
IO
N
B A
R N
E S
H A
L L D
O R
M
G R
A N
D F
O R
K S
A F
B N
O R
T H
D A
K O
T A
A-132
T H
IR
D
L E
V E
L R
E F
L E
C T
E D
C E
IL
IN
G P
L A
N
A R
E A
A
EXPOSED
STRUCTURE
EXPOSED
STRUCTURE
CEILING AREA; NO ACCESS
W
W
W
W
N
W
W
W
W
N
C02
KEY PLAN
AREA
C
AREA BAREA A
KEY PLAN
AREA
C
AREA BAREA A
CEILING PLAN LEGEND
EXISTING GYPSUM BOARD
CEILING TO REMAIN
EXISTING 2x2 ACOUSTICAL
PANEL CEILING TO REMAIN
LIGHT FIXTURES - SEE
ELECTRICAL
GRILLE AND DIFFUSERS -
SEE MECHANICAL
EXISTING WOOD GRID
SYSTEM TO REMAIN
GYPSUM BOARD CEILING
ACOUSTICAL PANEL CEILING
OUTLINE OF
ROOF
OVERHANG
DN DN
C02
C05
C01
REFLECTED CELING PLAN FLAG NOTES
C02
C03
C04
C05 REFLECTED CELING PLAN GENERAL NOTES
THIRD LEVEL REFLECTED CEILING PLAN - AREA C2
N
G R
A N
D F
O R
K S
A F
B
N D
C O
N T
R A
C T
S E
L E
M E
N T
C
IV
IL
E
N G
IN
E
E R
S Q
U A
D R
O N
A B C D E F G
Sheet of
NUMBER
REFERENCE
SHEET
A
IR
M O
B
IL
IT
Y
C O
M M
A N
D
D E
P A
R T
M E
N T
O F
T H
E A
IR
F
O R
C E
D R
A W
IN
G
N U
M B
E R
P L O
T S
C A
L E
T O
F O
R
/2 -S
IZ
E
P L O
T D
A T
E
C H
K B
Y
D W
N B
Y
D E
S
IG
N E
D B
Y
F
IL
E N
A M
E
D A
T E
S y m b o l
D e s c ri p tio n D a te
A p p ro v e d
S y m b o l
A p p ro v e d
D a te D e s c ri p tio n
D E
C
G J H
G J H
K L M
D E
C
IS
S
U E
D F
O R
B
ID
/C O
N S
T R
U C
T
IO
N
J F
S D
R E
P A
IR
F
IR
E
S U
P P
R E
S S
IO
N
B A
R N
E S
H A
L L D
O R
M
G R
A N
D F
O R
K S
A F
B N
O R
T H
D A
K O
T A
A-133
T H
IR
D
L E
V E
L R
E F
L E
C T
E D
C E
IL
IN
G P
L A
N
A R
E A
B A
N D
C
SCALE: 1/8" = 1'-0"
8' 4' 0 8'
THIRD LEVEL REFLECTED CEILING PLAN - AREA B1
N
File details come from the government source that posted it. Updated .