This document is a set of questions and answers related to Solicitation FA465424P0009 for a Storage Tank and Dispensing System. The solicitation is for a Lubricant Storage and Dispensing System for various oils, lubricants, and chemicals, with a requirement for 8 storage tanks of 65-gallon or greater capacity, made of aluminized steel. The system must include different colored tanks with matching identification labeling and hazardous material information, a 110V electrical pumping system, and inline filtration. The Q&A addresses details such as the specific fluids to be stored, the need for a safety compliance kit, and whether desiccant breathers are required. No fluids have a viscosity greater than 220cST. This document does not contain information about response dates, award dates, pricing terms, set-asides, or other contracting details.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Storage and Dispensing System Example.png | PNG image |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Solicitation FA465424P0009 Storage Tank and Dispensing System
Questions & Answers
Q. Are all of the fluids to be stored oils?
A. No
If not, please specify: (specified below)
Fluids to be stored are:
Hydraulic fluid RED (Need 2 tanks) Jet Oil: Purple Motor Oil: Beige (Need 2 tanks) Antifreeze: Dark Green Compressor Oil: Yellow Aircraft Soap: Blue
Note: preferred color of the tank has also been added.
Q. How many of the oils have a viscosity greater than 220cST?
A. None
Q. Do you want our Safety Compliance Kit on each tank. The Safety Compliance kit replaces the PVC hose with corrugated steel hose, replaces the PVC sight gauge with a glass sight gauge, and adds a fusible link valve which shuts off the oil flow from the tank when temperatures exceed 160F.
A. Yes
Q. Do you want inline filtration to each tank?
A. Yes
Q. Do you want desiccant breathers on each tank?
A. No