Attach_4_Drawings.pdf

PDF 3 MB Posted

Attached to
Repair LF Fuel Tank Venting Federal contract opportunity
Solicitation number
FA4626-16-R-0022
Issued by
Department of the Air Force Global Strike Command

About this file

Attachment 4 Drawings

View the file

Other files for this federal contract opportunity

Other files attached to Repair LF Fuel Tank Venting, newest first.
File Type Posted
Memo_for_Record.pdf PDF
Missile_Field_Distance_Chart.pdf PDF
WD's_Building_18_Mar_16.docx DOCX document
Updatedd_Drawings.pdf PDF
Amendment_1.pdf PDF
Preproposal_Conf_documents.pdf PDF
Attach_3_SCHEDULE_OF_DRAWINGS.doc DOC document
Attach_6_Base_Entry.pdf PDF
Attch_8_Past_Performance_Questionaire.docx DOCX document
Attach_5_Wage_Determinations_8_Jan_2016.docx DOCX document
Attach_7_Special_Contract_Requirements.docx DOCX document
Attach_2_Submittal_Schedule.xls XLS spreadsheet
LF_Fuel_Tank_RFP.pdf PDF
Attach_1 _Specs.zip ZIP file
Attch_9_-_Subcontractor_Consent_Form_-_10R0027.doc DOC document
Show all 15

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Cascade County Meagher Co.

Cascade County

Meagher Co.

Ca sc ad e C ou nty

Ju dit h B as in Co

Judith Basin Co.

Meagher Co.

Wheatland Co.

Fergus Co.

W he atl an d C o.

Golden Valley Co.

Fergus Co.

Fe rg us C o.

Ch ote au C o.

Choteau Co.

Judith Basin Co.

Choteau Co.

Cascade County

Te ton

C o.

Ch ote au C o.

Toole Co.

Choteau Co.

Teton Co.

Lewis & Clark Co.

Valier

Conrad

Pendroy

Bynum

Brady

Dutton

Gillman Augusta

Simms

Sun River

Cascade

Ulm Sand Coulee

Stockett

Eden

Monarch

Belt

Fort Benton

Montegue

Raynesford

Geyser

Stanford

Denton

Utica

Moccasin Ross Fork

MooreHobson

Garneill

Judith Gap

Winifred

Suffolk

Christina

Hilger

Brooks

RoyFergus

Forestgrove

Grassrange

Harlowton

Shawmut

Billings

Glasgow

Havre

MALMSTROM AFBGreat Falls

Helena

Butte

Rocky

Mountains

Fairfield

Helena: 89 Mi.

from MAFB from MAFB Butte: 153 Miles

Havre: 113 mi.

from MAFB from MAFB Malta: 238 Miles from MAFB Billings: 219 mi.

Wolf Creek

Lake Francis

Marias River

Lake Elwell

Kolin

Musselshell R.

Box Elder Cr.

Arrow Cr.

Wolf Cr.

Kingsburg Lake

Jud ith

R.

Cutback Cr.

Do g C r.

Missouri River

Coffee Creek

Windham

Big Spring Cr.

Jud ith

R.

Ackley Lake Crystal Lake

Sm ith

R ive r Ho un d C r

Miss our i R ive r

Little Muddy Cr.

Sun River

Dearborn R.

Collins

Muddy Cr.

Teton R.

Teton R.

Power

Vaughn

Big Lake

White Lake.

Ft Shaw

Geraldine

Square Butte

Tracy

Centerville

Freezeout Lake Benton Lake

Deadman Basin Reservoir

Box Elder Cr.

Miss our i R ive r

Choteau Co.

Fergus Co.

Fergus Co.

Pondera Co.

Teton Co.

Dupuyer

Bynum Reservoir

Piskun Reservoir

Sun River

Willow Creek Reservoir

Black Eagle

44 44

221 379

87239

F-10

F-2

F-11 H-11

H-2

J-1

J-2 J-11

J-3 J-4

J-7

J-5

J-6

J-8J-9

J-10

I-10

I-9

H-3

H-4

H-5

H-1287

F-1

F-9

F-8 F-3

H-10

F-5

F-6

F-4 H-9

H-8

H-7

I-11H-6 E-1

D-2

E-2

B-3 D-9

D-10 D-11

D-4

D-3

D-5

D-1

E-3

E-11

E-10

E-9

E-6

E-4

E-5

O-4

O-3O-11

O-10

O-2

O-1

O-6

O-5

O-7

N-3

N-2

N-10

N-11

O-9 O-8

N-9

M-3

M-4

E-7

M-1

E-8

M-2

M-11M-10

M-9

D-7 D-9

D-6

C-3

C-4

C-2

B-5

B-4

B-2

B-1

B-10

A-1

B-11

B-9

B-7

B-6

B-8

C-11

A-3

A-2 A-11

A-4

A-7

A-10

A-8

A-9

I-2

I-4

I-3

I-5

I-7

I-1

I-8

G-1 I-6

G-4

G-5

G-3 G-2

G-11 G-10

G-9

G-6

G-7 G-8

F-7

N-1 N-4N-6

N-5

N-7

N-8

M-5

M-6

M-7

M-8

C-5

C-10

C-8

C-6

C-7

L-11

L-9 L-2

L-10

C-1 C-9

A-5 A-6

L-1L-8

L-3

L-7 L-4

L-6

L-5

K-4

K-3

K-10

K-6

K-2

K-9

K-11

K-1

K-5

K-7

K-8

X-1

X-X

LEGEND

Overfill Alarm

To - OF Alm Sw TB pin 1

To - OF Alm Sw TB pin 5

(Neutral) CB-4 LDC

Rigid Conduit

FUEL SENSOR INTERFACE TB1-2

Transient Voltage

Suppressor

LINE (Hot)

LOAD (Hot)

NEUTRAL

Chassis

Ground

RFI Filter

GRN

BRN

BLU

(Neut)

LINE LOAD

(Hot)

(Neut)

(Hot)

BRN

BLU

1 2 3 4 5 6 7 8 9 10

RD

WH

BLK

Fuel Monitor Panel

Power

Module

Ground Lug

2A, Slo-Blo

Overfill Alarm Switch

(Neutral) CB-5 LDC

(Hot) CB-5 LDC

Printer

Interstitial Sensor Interface Module

Interstitial

Sensor

Sump

Sensor

Mag

Probe

Smart Sensor Interface Module

Probe/Thermistor Interface Module

1 2 3 4 5 6 7 8

BLK

RD

1 2 3 4 5 6 7 8

1 2 3 4 1 2 3 4

Probe Thermistor

BLK

RD

BLK

RD

Output

1 2 3 3 4 4

- + - + NC NO C NC NO C

Rigid Conduit

RD

RD

RD BLK

BLK

BLK

BLK

BLK

BLK

WH

WHWH

Sump Sensor

(Discriminating)

Diesel

Float

Water

Float

Magnetostrictive

Probe

Interstitial Switch (NC)

(Installed on dual-walled fiberglass tanks only)

N L1

ASU TB1-9

Barrier Ground

(#12 AWG or larger)

(Hot) CB-4 LDC

Chassis Ground

INTERSTITIAL SENSOR INTERFACE MODULE

1 2 3 4 5 6 7 8

BLK

RD

1 2 3 4 5 6 7 8

SMART SENSOR INTERFACE MODULE

INTERSTITIAL SENSOR

SUMP SENSOR

MAGNETOSTRICTIVE PROBE

PROBE/THERMISTOR INTERFACE MODULE

1 2 3 4 1 2 3 4

PROBE

THERMISTOR

SHIELDING

DRAIN WIRES

1 1 2 2 3 3 4 4

NC NO C NC NO C NC NO C NC NO C

OUTPUT

GMR 5 / OVERFILL ALARM

BLK

RD

BLK

RD

GROUND LUG

SUMP

SENSOR

INTERSTITIAL

SENSOR

BLK

BLK

BLK

BLK

WT

WT

WT

WHT

BRNBRN

BLU BLURED

LINE (HOT) LOAD

NEUT

HOT

NEUT

HOT

NEUT

LINE

LOAD

120 VAC LDA CB-13

NEUTRAL LDA CB-13

TRANSIENT VOLTAGE

SUPPRESSOR

RFI FILTER

CHASSIS GROUND

POWER BAY

POWER

MODULE

GROUND LUG

2A SLO-BLO

5x20MM

N L1

TO OVERFILL ALARM SWITCH TB PIN 5

TO OVERFILL ALARM SWITCH TB PIN 1

PIPING

SUMP

J-BOX

OVERFILL

ACKNOWLEDGE

SWITCH

OVERFILL

ALARM

BLU

RED

NEUTRAL LDA CB-15

120 VAC LDA CB-15

(4000 GAL TANKS ONLY)

2006C1-A8 (C)
2006C2-A8 (C)
2006E1-D8
2006E2-D8
2006M1-D8
2006M2-C8
2006M3-C8
2006M4-C8

File details come from the government source that posted it. Updated .