This is Amendment 01 to solicitation FA462025QA914 issued by the 92nd Contracting Squadron at Fairchild AFB for a blast deflector. The amendment provides answers to five questions from potential offerors regarding technical specifications, particularly clarifying panel dimensions and material requirements.

The amendment confirms that Panel 1 dimensions are 146-1/2" x 25-1/2" and Panel 2 is 98" x 25-1/2", correcting errors in the original specifications. It addresses questions about hardware details, bolt types (Grade 5 vs 304SS), and panel profiles - accepting 3" x 1" corrugations with 16 gauge G210 coated material for Panel Profile 1, and 2.67" x 1⁄2" corrugation with 14 gauge G90 coated material for Panel Profile 2. The amendment includes updated specifications in Attachment 1 with changes marked in red. Contractors are required to acknowledge the amendment and return one signed copy.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

EXCEPTION OF SF 30, APPROVED BY NARS 5/79

AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT

1. CONTRACT ID CODE

FA462025QA914

PAGE OF PAGES

2. AMENDMENT/MODIFICATION NO.

3. EFFECTIVE DATE

05Dec2024

4. REQUISITION/PURCHASE REQ. NO.

5. PROJECT NO. (If applicable)

6. ISSUED BY

CODE

FA4620 7. ADMINISTERED BY (If other than Item 6)

CODE

92nd Contracting Sq./PKA 110 W Ent St., Suite 200 SAME AS BLOCK 6 Fairchild AFB, WA 99011 Attn: brandon.teague.1@us.af.mil

8. NAME AND ADDRESS OF CONTRACTOR (No., street, county, State and ZIP Code) (√) 9A. AMENDMENT OF SOLICITATION NO.

X

FA462025QA914

All Offerors 9B. DATED (SEE ITEM 11)

27Nov2024

10A. MODIFICATION OF CONTRACT/ORDER

NO.

10B. DATED (SEE ITEM 13)

CODE FACILITY CODE

11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS

[X] The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers [] is extended, [X] is not extended.

Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended, by one of the following methods:

(a) By completing Items 8 and 15, and returning _1_ copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted; or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the hour and date specified.

12. ACCOUNTING AND APPROPRIATION DATA (If required)

13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACT/ORDERS,

IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.

A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT

ORDER NO. IN ITEM 10A.

B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).

C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:

D. OTHER (Specify type of modification and authority)

E. IMPORTANT: Contractor [] is not, [X] is required to sign this document and return _1_ copies to the issuing office.

14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)

SEE SUMMARY OF CHANGES

Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10 A, as heretofore changed, remains unchanged and in full force and effect.

15A. NAME AND TITLE OF SIGNER (Type or print)

16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)

2Lt. Brandon Teague, Contracting Officer

15B. CONTRACTOR/OFFEROR

(Signature of person authorized to sign)

15C. DATE SIGNED 16B. UNITED STATES OF AMERICA

BY

(Signature of Contracting Officer)

16C. DATE SIGNED

NSN 7540-01-152-8070 30-105-03 STANDARD FORM 30 (REV. 10-83)

PREVIOUS EDITION UNUSABLE Prescribed by GSA

FA462025QA914

Amendment 01 Page 2

SUMMARY OF CHANGES

The purpose of this Amendment is to:

1. Provide answers to questions posed by potential offerors in response to this solicitation.

Q1: I am seeing some conflicting information on this RFQ. The Attachment dimensions for each are, Panel 1(description) - 146-1/2” x 2-1/2” – Print, Panel 1 show 146-1/2” x 25”, Profile 1 shows 25-1/2” wide. Panel 2 (description) 98” x 25-1/2”, Panel 2 dimension – 98” x 25” and profile 2 shows 25-1/2” I’m guessing Panel 1 is 146-1/2” x 25-1/2” and Panel 2 is 98” x 25-1/2”? Please confirm.

A1: Panel 1 is 146-1/2” x 25-1/2” and Panel 2 is 98” x 25-1/2”. The government made an error in Attach. 1 – Item List, Blast Deflector Specs when transcribing over the specs from the Panel Specs drawing. The specs have been corrected and are annotated in red in Attach. 1 – Item List, Blast Deflector Specs (Amend 01).

Q2: Also are there any additional details regarding hardware? Are the bolts; socket head, hex, thumb screws…?

What is the OD of the flat washers? Any additional details on the half oval washers? Details on anti-seize?

A2: The government has added additional descriptive details to the above items in Attach. 1 – Item List, Blast Deflector Specs (Amend 01) and changes are annotated in red.

Q3: Another question on the grade 5 bolt ~ Grade 5. Manufactured from medium carbon steel and hardened for greater strength and durability, a grade 5 bolt is distinguished by 3 radial lines and promises tensile strengths between 105,000 and 120,000 psi. They are most commonly found in automotive applications or those that require medium strength. There is a 304 stainless steel bolt that is similar to Grade 5 but not as strong. Would you like the grade 5 quoted or the 304SS bolt?

A3: The government has modified the salient characteristics of the materials in Attach. 1 – Item List, Blast Deflector Specs (Amend 01) and changes are annotated in red.

Q4: Panel Profile 1 This corrugation depth measurement is 1” on what we supply. We can supply 16 Gage with a G210 minimum galvanization coating. If we supply 3” x 1” Corrugations, 16 Gauge, G210 Coated material for “Panel Profile 1” would this be acceptable?

A4: The government has reviewed the requirement and panel specs have been updated and are annotated in Attach. 1 – Item List, Blast Deflector Specs (Amend 01).

Q5: Panel Profile 2 Your Panel Specs state the corrugation is a 2 ¾” x 5/8” profile. We can provide 2.67” x ½” Sinewave corrugated profile. You ask for a 14 Gauge material. In 14 gauge we can only offer G90 coated material.

Would it be acceptable if we supply 2.67” x ½” Corrugation, 14 Gauge, G90 Coated material for “Panel Profile 2”?

A5: The government has reviewed the requirement and panel specs have been updated and are annotated in Attach. 1 – Item List, Blast Deflector Specs (Amend 01).

Fill out blocks 15a, 15b, and 15c and provide a copy with your proposal.

END SUMMARY OF CHANGES