Drawing Number Facility Number
Project Number
PROJECT TITLE
SHEET
SHEET TITLE
OF
REVISION BY/DATE
Designer
Drafter
Project Manager
Date
Engineer Pavements Engineer Corrosion
Protective Engineer
Coating Engr.
Fire Chief
Operations Chief of
Construction
Roofing Management
COORDINATION
Computers
Engineer
Systems Security Police Security
Bioenvironmental
Airfield
Safety Ground Manager
Communication
APPROVED
SIGNATURE
Chief of Engineering
Design Chief of
Contracting
User
OFFICE
Engineer Civil
DESIGN FIRM
APRIL 2018
TITLE 1-A
16 APRIL 2018
GW
AIRFIELD
OP#1054124
REPAIR TAXIWAY LIGHTING &
CIRCUIT FACILITY
BARKSDALE AIR FORCE BASE,
LOUISIANA 71110
8E
DRAFTER
RKC
BARKSDALE
AIR FORCE BASE
LOUISIANA
ROBBIN K. CASSITY, P.E.
26059
THESE DRAWINGS DO NOT INCLUDE NECESSARY
COMPONENTS FOR CONSTRUCTION SAFETY.
18-016
ENGINEER:
LICENSE NO.
CONSULTING ENGINEERS
3003 KNIGHT STREET, SUITE 120
SHREVEPORT, LOUISIANA 71105
phone: 318-425-7452 fax: 318-425-4622 www.AFJMc.com
COPYRIGHT NOTICE:
THIS ENGINEERING DRAWING SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH AFJMC. NO
OTHER USE DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF AFJMC.
ALL COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.
TITLE 1-B 35%
21 MAY 2018
TITLE 1-B 65%
27 JUNE 2018
TITLE 1-B 95%
29 AUG. 2018
TITLE 1-B 100% 08 OCT. 2018
T1
TITLE SHEET
DESCRIPTION
INDEX TO DRAWINGS
SHT. NO.
PROJECT LOCATION
T O
B O
S S
IE
R
C
IT
Y
T R
E A
T M
E N
T F
A C
IL
IT
IE
S
T
O
B
S
S
I E
R
C
I T
Y
T
R
E
A
T
M
E
N
F
A
C
I L
I T
I E
S
T A
X I W
A Y
C H
A R
L
X
I W
A Y
T
A
X
I
W
A
Y
I
N
D
I
A
D
R
T
W
I N
I N
G
R O
A D
S
E
C
U
R
I
T
Y
DR
C U
R T
I S
S
R
O
A
D
S
E
C
U
R
I T
Y
C O
O P
E R
B
A
Y
O
U
TRUE BEARING N 28 56'00''W 300' X 11,756'
INSTRUMENT RUNWAY
R
O
A D
S
E
C
U
R
I T
Y
O
I C
A R
U S
R I C
K E
N
B
A C
K E
R
D R
T W
I N
N I N
G
C H
I L D
B
R
A
V
X
I
W
A
Y
A V
E K
E N
N E
Y
A V
E
R D
L I N
D B
E R
G H
A V
E
A
V
E
R
I
C
K
E
N
B
A
C
K
E
R
R O
A D
A V
E L U
K E
D R
I V
E
M I T
C H
E L L
L
A
N
E
L
O
G
I S
T
I C
S
R
O
A
D
R
E
A
D
I N
E
S
S
O
TRUE BEARING N 28 56'00'' W 300' X 11,756'
APRONPARKING
B
L
V
D
J
A
M
E
S
R
D
AVENUE
ROAD
P
I
P
E
B A
R K
S D
A L E
B A
R K
S D
A L E
W E
S T
E A
S T
B L V
D
B L V
D
B
O
N
G
B
L
V
D
L
A
N
G
L
E
Y
D
R
W
I
L
B
U
R
W
R
I
G
H
T
D
R
T
W
I N
I N
G
K
E
N
N
E
Y
A
V
E
D
O
U
H
E
T
D
R
M
O
N
T
G
O
L
F
I
E
R
S
P
A
A
T
Z
A
R
N
O
L
D
C
H
E
N
N
A
U
L
T
I
R
A
E
A
K
E
R
D
R
F
O
U
L
O
I S
H
A
P
S
H
R
E
V
E
P
O
R
T
R
O
A
D
S
E
L
F
R
I
D
G
E
A
V
E
L
U
K
E
A
V
E
A
V
E
E
A
R
H
A
R
T
A
V
E
B
IL
L
Y
M
I
T
C
H
E
L
L
D
R
R
I
C
K
E
N
B
A
C
K
E
R
A
V
E
K
E
N
N
E
Y
A
V
E
P
E
L
I
C
A
N
D
R
L
O
U
I
S
I
A
N
A
B
L
V
D
A
V
E
S
H
R
E
V
E
P
O
R
T
B I L L Y
B
I
L
L
Y
M
I
T
C
H
E
L
L
D
R
I
V
E
F A
I R
N
O
R
H
X
I W
Y
S
T
INSTRUMENT RUNWAY
A
L
P
X
I W
A
Y
PARKING APRON
150' X 5,000
APRON LOADING
LINDBERGH
R
D
D
A
E
D
A
L
U
S
A
V
E
S H
R E
V E
P O
R T
R D
S
H
R
E
V
E
P
O
R
T
R
D
D A
E D
A L U
S A
V E
DAVIS
B O
S S
I E
R
O
R
V
I
L
L
E
W
R
I
G
H
T
A
V
E
A
V
E
V
A
N
D
E
N
B
E
R
G
A
V
E
A
V
E
R
O
A
D
B
L
V
D
O R
V I L L E
W R
I G
H T
A V
E
V A
N D
E N
B E
R G
A V
E
R
O
A
D
A
L
E
R
X
I
W
A
Y
E
C
X
I
W
Y
D
L T
A
T1 TITLE SHEET
E1 ELECTRICAL GENERAL NOTES
E2 ELECTRICAL SITE TAXIWAY LIGHTING
E3 ELECTRICAL ENLARGED TAXIWAY LIGHTING PLAN
E4 ELECTRICAL ENLARGED TAXIWAY LIGHTING PLAN
E5 ELECTRICAL ENLARGED TAXIWAY LIGHTING PLAN
E6 ELECTRICAL ENLARGED TAXIWAY LIGHTING PLAN
E7 ELECTRICAL ENLARGED TAXIWAY LIGHTING PLAN
FA4608-19-R-A011
Attachment 2 Drawings
AutoCAD SHX Text N
AutoCAD SHX Text
BARKSDALE AIR FORCE
AutoCAD SHX Text
RD.
AutoCAD SHX Text
INDUSTRAIL LOOP
AutoCAD SHX Text
AIRPORT
AutoCAD SHX Text
LINWOOD AVE.
AutoCAD SHX Text
INNER
AutoCAD SHX Text
RD.
AutoCAD SHX Text
PINE
AutoCAD SHX Text W. 70th.
AutoCAD SHX Text
LOOP
AutoCAD SHX Text
MANSFIELD
AutoCAD SHX Text
EXPRESSWAY
AutoCAD SHX Text
MUNICIPAL
AutoCAD SHX Text
DR.
AutoCAD SHX Text
LAKE
AutoCAD SHX Text
LAKESHORE
AutoCAD SHX Text
RD.
AutoCAD SHX Text p
AutoCAD SHX Text
HOLLYWOOD AV.
AutoCAD SHX Text
AutoCAD SHX Text
MILAM
AutoCAD SHX Text E. 70
AutoCAD SHX Text
LOOP
AutoCAD SHX Text
INDUSTRAIL
AutoCAD SHX Text
RIVER
AutoCAD SHX Text
RED
AutoCAD SHX Text
AutoCAD SHX Text
RIVER
AutoCAD SHX Text
PKWY.
AutoCAD SHX Text
MENORIAL
AutoCAD SHX Text
YOUREE DR.
AutoCAD SHX Text
LINE AVE.
AutoCAD SHX Text
STONER AVE.
AutoCAD SHX Text
KINGS HWY.
AutoCAD SHX Text
RED
AutoCAD SHX Text
CLYDE
AutoCAD SHX Text
FANT
AutoCAD SHX Text
N. MARKET
AutoCAD SHX Text
LAKESHORE
AutoCAD SHX Text
CROSS
AutoCAD SHX Text
DR.
AutoCAD SHX Text
BLANCHARD
AutoCAD SHX Text
SHREVEPORT
AutoCAD SHX Text
ROAD
AutoCAD SHX Text
HWY.
AutoCAD SHX Text
ROY
AutoCAD SHX Text p
AutoCAD SHX Text
AutoCAD SHX Text
AV.
AutoCAD SHX Text
AutoCAD SHX Text
HEARNE
AutoCAD SHX Text
AutoCAD SHX Text p
AutoCAD SHX Text
RD.
AutoCAD SHX Text
DRIVE
AutoCAD SHX Text
BENTON
AutoCAD SHX Text
AIRLINE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text p
AutoCAD SHX Text
AutoCAD SHX Text
BASE
AutoCAD SHX Text
BARKSDALE AIR FORCE BASE, LOUISIANA
AutoCAD SHX Text
TITLE 1B - 100%%% SUBMITTAL
AutoCAD SHX Text
REPAIR TAXIWAY LIGHTING
AutoCAD SHX Text
LS5937
AutoCAD SHX Text
LS5948
AutoCAD SHX Text
LS6831
AutoCAD SHX Text
LS6852
AutoCAD SHX Text
LS6805
AutoCAD SHX Text
LS6829
AutoCAD SHX Text
LS4511
AutoCAD SHX Text
LS4725
AutoCAD SHX Text
LS3932
AutoCAD SHX Text
LS6049
AutoCAD SHX Text
LS2926
AutoCAD SHX Text
LS1924
AutoCAD SHX Text
LS1956
AutoCAD SHX Text
LS6459
AutoCAD SHX Text
LS6654
AutoCAD SHX Text
LS6393
AutoCAD SHX Text
LS6563
AutoCAD SHX Text
LS3455
AutoCAD SHX Text
LS5346
AutoCAD SHX Text
OWS6653
AutoCAD SHX Text
OWS6827
AutoCAD SHX Text
OWS6850
AutoCAD SHX Text
OWS6824
AutoCAD SHX Text
OWS6638
AutoCAD SHX Text
OWS6649
AutoCAD SHX Text
OWS5934
AutoCAD SHX Text
OWS5950
AutoCAD SHX Text
OWS6626
AutoCAD SHX Text
OWS5930
AutoCAD SHX Text
OWS6604
AutoCAD SHX Text
OWS6826
AutoCAD SHX Text
OWS6830
AutoCAD SHX Text
OWS4401
AutoCAD SHX Text
OWS4143
AutoCAD SHX Text
OWS5778
AutoCAD SHX Text
OWS6438
AutoCAD SHX Text
OWS6437
AutoCAD SHX Text
OWS6425
AutoCAD SHX Text
OWS6215
AutoCAD SHX Text
OWS6213
AutoCAD SHX Text
OWS6203
AutoCAD SHX Text
OWS4186
AutoCAD SHX Text
OWS4163
AutoCAD SHX Text
OWS4168
AutoCAD SHX Text
OWS6850
AutoCAD SHX Text
COMM.
AutoCAD SHX Text S.S.
AutoCAD SHX Text S.S.
AutoCAD SHX Text S.S.
AutoCAD SHX Text G.
AutoCAD SHX Text G.
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text
AND CIRCUIT FACILITY #99715
Drawing Number Facility Number
Project Number
PROJECT TITLE
SHEET
SHEET TITLE
OF
REVISION BY/DATE
Designer
Drafter
Project Manager
Date
Engineer Pavements Engineer Corrosion
Protective Engineer
Coating Engr.
Fire Chief
Operations Chief of
Construction
Roofing Management
COORDINATION
Computers
Engineer
Systems Security Police Security
Bioenvironmental
Airfield
Safety Ground Manager
Communication
APPROVED
SIGNATURE
Chief of Engineering
Design Chief of
Contracting
User
OFFICE
Engineer Civil
DESIGN FIRM
APRIL 2018
TITLE 1-A
16 APRIL 2018
GW
AIRFIELD
OP#1054124
REPAIR TAXIWAY LIGHTING &
CIRCUIT FACILITY
BARKSDALE AIR FORCE BASE,
LOUISIANA 71110
8E
DRAFTER
RKC
BARKSDALE
AIR FORCE BASE
LOUISIANA
ROBBIN K. CASSITY, P.E.
26059
THESE DRAWINGS DO NOT INCLUDE NECESSARY
COMPONENTS FOR CONSTRUCTION SAFETY.
18-016
ENGINEER:
LICENSE NO.
CONSULTING ENGINEERS
3003 KNIGHT STREET, SUITE 120
SHREVEPORT, LOUISIANA 71105
phone: 318-425-7452 fax: 318-425-4622 www.AFJMc.com
COPYRIGHT NOTICE:
THIS ENGINEERING DRAWING SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH AFJMC. NO
OTHER USE DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF AFJMC.
ALL COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.
TITLE 1-B 35%
21 MAY 2018
TITLE 1-B 65%
27 JUNE 2018
TITLE 1-B 95%
29 AUG. 2018
TITLE 1-B 100% 08 OCT. 2018
E1
ELECTRICAL GENERAL
NOTES
(APPLICABLE TO ALL ELECTRICAL DRAWINGS)
THE PLANS AND SPECIFICATIONS ARE ISSUED AS A COMPLETE SET. THE
CONTRACTOR SHALL THOROUGHLY REVIEW THE COMPLETE SET OF DOCUMENTS
IN ASCERTAINING THE SCOPE OF WORK AND IN COORDINATION OF HIS WORK WITH
THAT OF OTHER TRADES. ANY CONFLICTS SHALL BE BROUGHT TO THE IMMEDIATE
ATTENTION OF 2CES FOR RESOLUTION.
PRIOR TO SUBMITTING A BID THE CONTRACTOR SHALL VISIT THE SITE, REVIEW THE
EXISTING CONDITIONS AND ALLOW FOR LABOR, MATERIAL AND COORDINATION
THAT IS NECESSARY TO PROVIDE A COMPLETE AND INTEGRATED INSTALLATION
OF EACH SYSTEM. CONTRACTOR SHALL TAKE CARE IN ASCERTAINING THE
REQUIREMENTS TO INTEGRATE ANY NEW SYSTEMS OR EQUIPMENT WITH
EXISTING.
WHERE FIXTURE QUANTITIES ARE SHOWN ON DRAWINGS THEY ARE FOR AREA
FIXTURE TYPE REFERENCE ONLY. CONTRACTOR IS RESPONSIBLE FOR FIXTURE
COUNT AND SHALL VERIFY ALL FIXTURE QUANTITIES PRIOR TO BIDDING.
TAXIWAY LIGHT FIXTURES ARE SHOWN IN APPROXIMATE LOCATIONS.
PROVIDE AS-BUILT PLANS INDICATING ANY DEVIATIONS OF CONDITIONS FOUND IN
THE FIELD FROM THAT WHICH IS SHOWN. ADDITIONALLY, SHOW ACTUAL ROUTING
OF RDR MARKER CABLING AS INSTALLED.
GENERAL NOTES
THIS PROJECT CONSISTS OF THE REPLACEMENT OF EXISTING TAXIWAY LIGHTING
WITH NEW LED FIXTURES FOR THE FOLLOWING TAXIWAYS: ALERT, ALPHA,
CHARLIE, DELTA, ECHO 2 AND PARALLEL. (ONE) NEW FIXTURE WILL ALSO BE
INSTALLED AND ADDED TO THE ALERT TAXIWAY AND DELTA TAXIWAY. (TWO) NEW
FIXTURES WILL BE INSTALLED AND ADDED TO THE ECHO 2 TAXIWAY.
IN ADDITION, EXISTING CIRCUIT CONDUCTORS AND ISOLATION TRANSFORMERS
WILL BE REPLACED WITH NEW FOR ALL TAXIWAYS - INCLUDING BRAVO, EXTENDING
FROM THE SOURCE (REGULATOR) IN THE AIRFIELD LIGHTING VAULT TO THE
FIXTURE. WHERE DIRECT BURIED CABLE EXISTS ON TAXIWAYS ALERT, ALPHA AND
DELTA, IT SHALL BE REPLACED WITH NEW WIRE IN CONDUIT DUCT. WHERE NEW
DUCT IS INSTALLED A GROUND CONDUCTOR SHALL BE PROVIDED EXTERNAL AND
ON TOP OF THE CONDUIT AND BONDED TO THE EXISTING COUNTERPOISE SYSTEM.
SCOPE-OF-WORK
EXISTING DUCT ROUTING MANHOLE/HANDHOLE LOCATIONS AND FIXTURE
CIRCUITING MAY DIFFER FROM THAT SHOWN ON THE PLAN. THE PLANS ARE
INTENDED TO PROVIDE A GENERAL INDICATION OF EXISTING CONDITIONS AND
INTENDED CIRCUITING AS TAKEN FROM PREVIOUS PLANS AND LIMITED FIELD
VERIFICATION. ACTUAL DUCT, MANHOLE, AND CIRCUIT ROUTINGS SHALL BE
MARKED AND ANNOTATED ON "AS-BUILT" PLANS.
+ 2 OTHER
LTG CIRCUITS
A-A
B-B
C-C
D-D
G-G
SCALE: NONE
EXISTING DUCTS SHOWN ARE TAKEN FROM EXISTING PLANS. ACTUAL FIELD
CONDITIONS MAY VARY. REPLACEMENT TAXIWAY LIGHTING CIRCUIT
CONDUCTORS MAY FOLLOW THE INDICATED ROUTING. ALTERNATE ROUTING
VIA EXISTING DUCT MAY BE UTILIZED PENDING APPROVAL BY 2CES AND THE
BAFB ELECTRIC SHOP. THE ROUTING OF OTHER EXISTING AIRFIELD LIGHTING
CIRCUIT CONDUCTORS WHICH ARE TO REMAIN MAY DIFFER FROM THAT
SHOWN.
A B
+ 2 OTHER
LTG CIRCUITS
D EC
+ 2 OTHER
LTG CIRCUITS
A B
E-E
+ 1 OTHER
LTG CIRCUIT
D E
+ 1 OTHER
LTG CIRCUIT
E
F-F
+ 1 OTHER
LTG CIRCUIT
A B
H-H
A
I-I
ALERT TAXIWAY
CIRCUIT LEGEND
A
ALPHA TAXIWAYB
BRAVO TAXIWAYC
CHARLIE TAXIWAYD
DELTA TAXIWAYE
ECHO 2 TAXIWAYF
PARALLEL TAXIWAYG
SUBSCRIPT NUMBER, DENOTES NUMBER OF CIRCUIT
CONDUCTORS. WHERE NO SUBSCRIPT IS GIVEN, ONE
CONDUCTOR IS INTENDED.
G
+ 1 OTHER
LTG CIRCUITS
D EC G
+ 1 OTHER
LTG CIRCUIT
F
+ 1 OTHER
LTG CIRCUITS
DE CG
1. NEW LIGHTING CIRCUIT DUCT SHALL BE INSTALLED IN
ACCORDANCE WITH UFC 3-535-01 AND FAA AC 150/5370-10G
REQUIREMENTS.
2. COUNTERPOISE CONDUCTOR SHALL BE INSTALLED IN
ACCORDANCE WITH UFC 3-535-01 AND FAA AC 150/5340-30F
REQUIREMENTS.
#4 BARE CU COUNTERPOISE. BOND TO
EXISTING COUNTERPOISE SYSTEM
TAMPED BACKFILL
2"C SCH 40 PVC COVERED
BY 3" RED CONCRETE ON
ALL ALL SIDES
CONDUIT SUPPORT
MIN 5FT ON CENTER
6"
M
I N
AF
AFF
AFG
AIC
AL
AS
AT
ATS
AWG
BCG
BLDG
C
CB
CKT
CL
CLR
CO
CSFD
CTR
CU
DIA
DP
DWG
EMS
EMT
ELR
EPO
EPR
EQ
FA
FAAP
FACP
FAPS
FARP
FLA
FVNR
G
GALV
RGS
GFI
HD
HH
HID
HO
HOA
HP
HPS
HSP
HV
HZ
ISC
IG
INST
JB
AMPERE FRAME/FUSE
ABOVE FINISHED FLOOR
ABOVE FINISHED GRADE
AMPS INTERRUPTING CURRENT
ALUMINUM
AMPERE SWITCH
AMPERES TRIP
AUTOMATIC TRANSFER SWITCH
BARE COPPER GROUND
BUILDING
CONDUIT
CIRCUIT BREAKER
CIRCUIT
CENTER LINE
CLEAR
CONDUIT ONLY
COMBINATION SMOKE/FIRE DAMPER
CENTER
COPPER
DIAMETER
DISTRIBUTION PANEL
ENERGY MANAGEMENT SYSTEM
ELECTRICAL METALLIC TUBING
END-OF-LINE RESISTOR
EMERGENCY POWER OFF
ETHYLENE PROPYLENE RUBBER
EQUAL
FIRE ALARM
FIRE ALARM ANNUNCIATOR PANEL
FIRE ALARM CONTROL PANEL
FIRE ALARM POWER SUPPLY
FIRE ALARM REMOTE PANEL
FULL LOAD AMPERES
FULL VOLTAGE NON-REVERSING
GROUND
GALVANIZED
RIGID GALVANIZED STEEL
GROUND FAULT INTERRUPTER
HANDHOLE
HIGH INTENSITY DISCHARGE
HIGH OUTPUT
HAND-OFF-AUTO
HORSEPOWER
HIGH PRESSURE SODIUM
HOUSE SERVICE PANEL
HIGH VOLTAGE
HERTZ
INTERRUPTING SHORT CIRCUIT
ISOLATED GROUND
INSTANTANEOUS
JUNCTION BOX
KV
KVA
KW
KWH
LCP
MCB
MCC
MCCB
MCP
MH
MIC
MLO
MSB
MSG
N
NC
NIC
NL
NO
NTS
OC
OH
PA
PB
PH.
POC
PVC
REC
REQ'D
RSC
SEC
SWBD
SYM
TD
TTB
TTC
UG
UL
UON
VFD
W/
WH
WP
XFMR
XLPE
XP
+4'-6"
KILOVOLTS
KILOVOLT-AMPERES
KILOWATTS
KILOWATT-HOURS
LIGHTING CONTROL PANEL
MAIN CIRCUIT BREAKER
MOTOR CONTROL CENTER
MOLDED CASE CIRCUIT BREAKER
MOTOR CIRCUIT PROTECTOR
MANHOLE
MICROPHONE
MAIN LUGS ONLY
MAIN SWITCHBOARD
MAIN SWITCHGEAR
NEUTRAL
NORMALLY CLOSED
NOT IN CONTRACT
NIGHT LIGHT (NON-SWITCHED)
NORMALLY OPEN, NUMBER
NOT TO SCALE
ON CENTER
OVERHEAD
PUBLIC ADDRESS
PUSHBUTTON
PHASE
POINT OF CONNECTION
POLYVINYL CHLORIDE
RECEPTACLE
REQUIRED
RIGID STEEL CONDUIT
SECONDARY
SWITCHBOARD
SYMMETRICAL
TIME DELAY
TELEPHONE TERMINAL BOARD
TELEPHONE TERMINAL CABINET
UNDERGROUND
UNDERWRITERS LABORATORIES
UNLESS OTHERWISE NOTED
VARIABLE FREQUENCY DRIVE
WITH
WATER HEATER
WEATHERPROOF
TRANSFORMER
CROSS LINKED POLYETHYLENE
EXPLOSION PROOF
TYPICAL MOUNTING HEIGHT 4'-6" ABOVE
FLOOR OR GRADE TO CENTER OF BOX
HEAT DETECTOR
DRAWING
AMERICAN WIRE GAUGE
ABBREVIATIONS
FAA FEDERAL AVIATION ADMINISTRATION
FINISHED GRADE
FA4608-19-R-A011
Attachment 2 Drawings
AutoCAD SHX Text
EXISTING DUCT SECTIONS
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
NEW TAXIWAY LIGHTING CIRCUIT DUCT
DELTA
CHARLIE
BRAVO
ECHO 2
ALPHA
ALERT
PARALLEL
119A
E
REFERENCE ENLARGED
PLAN, SHEET E6
REFERENCE ENLARGED
PLAN, SHEET E6
REFERENCE ENLARGED
PLAN, SHEET E7
REFERENCE ENLARGED
PLAN, SHEET E5
REFERENCE ENLARGED
PLAN, SHEET E5
REFERENCE ENLARGED
PLAN, SHEET E4
REFERENCE ENLARGED
PLAN, SHEET E3
AIRFIELD LIGHTING
VAULT, B6414
F
F
E
E
G
G
D
D
H
H
S
E
C
T
I
D
D
A B
I
I
B
A B
A B
B
A
A
C
C
B
B
F
F
Drawing Number Facility Number
Project Number
PROJECT TITLE
SHEET
SHEET TITLE
OF
REVISION BY/DATE
Designer
Drafter
Project Manager
Date
Engineer Pavements Engineer Corrosion
Protective Engineer
Coating Engr.
Fire Chief
Operations Chief of
Construction
Roofing Management
COORDINATION
Computers
Engineer
Systems Security Police Security
Bioenvironmental
Airfield
Safety Ground Manager
Communication
APPROVED
SIGNATURE
Chief of Engineering
Design Chief of
Contracting
User
OFFICE
Engineer Civil
DESIGN FIRM
APRIL 2018
TITLE 1-A
16 APRIL 2018
GW
AIRFIELD
OP#1054124
REPAIR TAXIWAY LIGHTING &
CIRCUIT FACILITY
BARKSDALE AIR FORCE BASE,
LOUISIANA 71110
8E
DRAFTER
RKC
BARKSDALE
AIR FORCE BASE
LOUISIANA
ROBBIN K. CASSITY, P.E.
26059
THESE DRAWINGS DO NOT INCLUDE NECESSARY
COMPONENTS FOR CONSTRUCTION SAFETY.
18-016
ENGINEER:
LICENSE NO.
CONSULTING ENGINEERS
3003 KNIGHT STREET, SUITE 120
SHREVEPORT, LOUISIANA 71105
phone: 318-425-7452 fax: 318-425-4622 www.AFJMc.com
COPYRIGHT NOTICE:
THIS ENGINEERING DRAWING SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH AFJMC. NO
OTHER USE DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF AFJMC.
ALL COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.
TITLE 1-B 35%
21 MAY 2018
TITLE 1-B 65%
27 JUNE 2018
TITLE 1-B 95%
29 AUG. 2018
TITLE 1-B 100% 08 OCT. 2018
1. REFERENCE ENLARGED PLANS FOR TAXIWAY FIXTURE
LOCATIONS.
E2
ELECTRICAL SITE
TAXIWAY LIGHTING PLAN
N
O
R
T
H
N
SCALE: 1"=500'
FA4608-19-R-A011
Attachment 2 Drawings
AutoCAD SHX Text
TO BOSSIER CITY
AutoCAD SHX Text
TREATMENT FACILITIES
AutoCAD SHX Text
TO BOSSIER CITY
AutoCAD SHX Text
TREATMENT FACILITIES
AutoCAD SHX Text
LS5937
AutoCAD SHX Text
LS5948
AutoCAD SHX Text
LS6831
AutoCAD SHX Text
LS6852
AutoCAD SHX Text
LS6805
AutoCAD SHX Text
LS6829
AutoCAD SHX Text
LS4511
AutoCAD SHX Text
LS4725
AutoCAD SHX Text
LS3932
AutoCAD SHX Text
LS6049
AutoCAD SHX Text
LS2926
AutoCAD SHX Text
LS1924
AutoCAD SHX Text
LS1956
AutoCAD SHX Text
LS6459
AutoCAD SHX Text
LS6654
AutoCAD SHX Text
LS6563
AutoCAD SHX Text
LS7768
AutoCAD SHX Text
LS3455
AutoCAD SHX Text
LS5346
AutoCAD SHX Text
OWS6653
AutoCAD SHX Text
OWS6827
AutoCAD SHX Text
OWS6850
AutoCAD SHX Text
OWS6824
AutoCAD SHX Text
OWS6638
AutoCAD SHX Text
OWS6649
AutoCAD SHX Text
OWS5934
AutoCAD SHX Text
OWS5950
AutoCAD SHX Text
OWS6626
AutoCAD SHX Text
OWS5930
AutoCAD SHX Text
OWS6604
AutoCAD SHX Text
OWS6826
AutoCAD SHX Text
OWS6830
AutoCAD SHX Text
OWS4401
AutoCAD SHX Text
OWS4143
AutoCAD SHX Text
OWS5778
AutoCAD SHX Text
OWS6438
AutoCAD SHX Text
OWS6437
AutoCAD SHX Text
OWS6425
AutoCAD SHX Text
OWS6215
AutoCAD SHX Text
OWS6213
AutoCAD SHX Text
OWS6203
AutoCAD SHX Text
OWS4186
AutoCAD SHX Text
OWS4163
AutoCAD SHX Text
OWS4168
AutoCAD SHX Text
OWS6850
AutoCAD SHX Text
TAXIWAY
AutoCAD SHX Text
CHARLIE TAXIWAY
AutoCAD SHX Text
TAXIWAY
AutoCAD SHX Text
INDIA
AutoCAD SHX Text
DR
AutoCAD SHX Text
TWINING
AutoCAD SHX Text
ROAD
AutoCAD SHX Text
SECURITY
AutoCAD SHX Text
DR
AutoCAD SHX Text
CURTISS
AutoCAD SHX Text
SECURITY
AutoCAD SHX Text
TRUE BEARING N 28 56'00''W 300' X 11,756'
AutoCAD SHX Text
INSTRUMENT RUNWAY
AutoCAD SHX Text
RADIO RECEIVER SITE ROAD
AutoCAD SHX Text
ROAD
AutoCAD SHX Text
SECURITY
AutoCAD SHX Text O
AutoCAD SHX Text
CONVOY
AutoCAD SHX Text
ICARUS
AutoCAD SHX Text
RICKEN BACKER
AutoCAD SHX Text
DR
AutoCAD SHX Text
TWINNING
AutoCAD SHX Text
CHILD
AutoCAD SHX Text
BRAVO TAXIWAY
AutoCAD SHX Text
AVE
AutoCAD SHX Text
KENNEY
AutoCAD SHX Text
AVE
AutoCAD SHX Text
RD
AutoCAD SHX Text
LINDBERGH
AutoCAD SHX Text
AVE
AutoCAD SHX Text
AVE
AutoCAD SHX Text
RICKENBACKER
AutoCAD SHX Text
ROAD
AutoCAD SHX Text
AVE
AutoCAD SHX Text
LUKE
AutoCAD SHX Text
DRIVE
AutoCAD SHX Text
MITCHELL
AutoCAD SHX Text
LANE
AutoCAD SHX Text
LOGISTICS
AutoCAD SHX Text
ROAD
AutoCAD SHX Text
READINESS
AutoCAD SHX Text O
AutoCAD SHX Text
TRUE BEARING N 28 56'00'' W 300' X 11,756'
AutoCAD SHX Text
APRON
AutoCAD SHX Text
PARKING
AutoCAD SHX Text
BLVD
AutoCAD SHX Text
JAMES
AutoCAD SHX Text
RD
AutoCAD SHX Text
AVENUE
AutoCAD SHX Text
ROAD
AutoCAD SHX Text
PIPE
AutoCAD SHX Text
BARKSDALE
AutoCAD SHX Text
BARKSDALE
AutoCAD SHX Text
WEST
AutoCAD SHX Text
EAST
AutoCAD SHX Text
BLVD
AutoCAD SHX Text
BLVD
AutoCAD SHX Text
BONG
AutoCAD SHX Text
BLVD
AutoCAD SHX Text
LANGLEY
AutoCAD SHX Text
DR
AutoCAD SHX Text
WILBUR
AutoCAD SHX Text
WRIGHT
AutoCAD SHX Text
DR
AutoCAD SHX Text
TWINING
AutoCAD SHX Text
KENNEY
AutoCAD SHX Text
AVE
AutoCAD SHX Text
DOUHET
AutoCAD SHX Text
DR
AutoCAD SHX Text
MONTGOLFIER
AutoCAD SHX Text
SPAATZ
AutoCAD SHX Text
ARNOLD
AutoCAD SHX Text
CHENNAULT
AutoCAD SHX Text
IRA
AutoCAD SHX Text
EAKER
AutoCAD SHX Text
DR
AutoCAD SHX Text
FOULOIS
AutoCAD SHX Text
HAP
AutoCAD SHX Text
SHREVEPORT
AutoCAD SHX Text
ROAD
AutoCAD SHX Text
SELFRIDGE
AutoCAD SHX Text
AVE
AutoCAD SHX Text
LUKE
AutoCAD SHX Text
AVE
AutoCAD SHX Text
AVE
AutoCAD SHX Text
EARHART
AutoCAD SHX Text
AVE
AutoCAD SHX Text
BILLY
AutoCAD SHX Text
MITCHELL
AutoCAD SHX Text
DR
AutoCAD SHX Text
RICKENBACKER
AutoCAD SHX Text
AVE
AutoCAD SHX Text
KENNEY
AutoCAD SHX Text
AVE
AutoCAD SHX Text
PELICAN
AutoCAD SHX Text
DR
AutoCAD SHX Text
LOUISIANA
AutoCAD SHX Text
BLVD
AutoCAD SHX Text
AVE
AutoCAD SHX Text
SHREVEPORT
AutoCAD SHX Text
BILLY
AutoCAD SHX Text
BILLY
AutoCAD SHX Text
MITCHELL
AutoCAD SHX Text
DRIVE
AutoCAD SHX Text
FAIR
AutoCAD SHX Text
NORTH TAXIWAY EAST
AutoCAD SHX Text
INSTRUMENT RUNWAY
AutoCAD SHX Text
ALPHA TAXIWAY
AutoCAD SHX Text
PARKING APRON
AutoCAD SHX Text 150' X 5,000
AutoCAD SHX Text
APRON LOADING
AutoCAD SHX Text
LINDBERGH
AutoCAD SHX Text
RD
AutoCAD SHX Text
DAEDALUS
AutoCAD SHX Text
AVE
AutoCAD SHX Text
SHREVEPORT
AutoCAD SHX Text
RD
AutoCAD SHX Text
SHREVEPORT
AutoCAD SHX Text
RD
AutoCAD SHX Text
DAEDALUS
AutoCAD SHX Text
AVE
AutoCAD SHX Text
DAVIS
AutoCAD SHX Text
BOSSIER
AutoCAD SHX Text
ORVILLE
AutoCAD SHX Text
WRIGHT
AutoCAD SHX Text
AVE
AutoCAD SHX Text
AVE
AutoCAD SHX Text
VANDENBERG
AutoCAD SHX Text
AVE
AutoCAD SHX Text
AVE
AutoCAD SHX Text
ROAD
AutoCAD SHX Text
BLVD
AutoCAD SHX Text
ORVILLE
AutoCAD SHX Text
WRIGHT
AutoCAD SHX Text
AVE
AutoCAD SHX Text
VANDENBERG
AutoCAD SHX Text
AVE
AutoCAD SHX Text
ROAD
AutoCAD SHX Text
COMM.
AutoCAD SHX Text S.S.
AutoCAD SHX Text S.S.
AutoCAD SHX Text S.S.
AutoCAD SHX Text G.
AutoCAD SHX Text G.
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text
ALERT TAXIWAY
AutoCAD SHX Text
ECHO 2 TAXIWAY
AutoCAD SHX Text
DELTA
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
%%UELECTRICAL NOTES%%U:
ELECTRICAL SITE PLAN
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
TT
T
T
T
T
TTTT
TT
T
T
T
T
T
T
T
TT
T T TT
T T
T T
T
TTT
T T T
S
M
T
C
H
L
I
S
E
T
T
T
T
T
T
3 4
TYP. UON.
A
A
A
A
A
A
A
A
AAAA
A
A
A
A
5 TYP.
EXISTING DUCT BETWEEN FIXTURES (TYP)
A B
B
A B
A B
A B
A B
A B
A
A
B B
A
B
A
B
B
B
B
B
B
A
B
B
A B
Drawing Number Facility Number
Project Number
PROJECT TITLE
SHEET
SHEET TITLE
OF
REVISION BY/DATE
Designer
Drafter
Project Manager
Date
Engineer Pavements Engineer Corrosion
Protective Engineer
Coating Engr.
Fire Chief
Operations Chief of
Construction
Roofing Management
COORDINATION
Computers
Engineer
Systems Security Police Security
Bioenvironmental
Airfield
Safety Ground Manager
Communication
APPROVED
SIGNATURE
Chief of Engineering
Design Chief of
Contracting
User
OFFICE
Engineer Civil
DESIGN FIRM
APRIL 2018
TITLE 1-A
16 APRIL 2018
GW
AIRFIELD
OP#1054124
REPAIR TAXIWAY LIGHTING &
CIRCUIT FACILITY
BARKSDALE AIR FORCE BASE,
LOUISIANA 71110
8E
DRAFTER
RKC
BARKSDALE
AIR FORCE BASE
LOUISIANA
ROBBIN K. CASSITY, P.E.
26059
THESE DRAWINGS DO NOT INCLUDE NECESSARY
COMPONENTS FOR CONSTRUCTION SAFETY.
18-016
ENGINEER:
LICENSE NO.
CONSULTING ENGINEERS
3003 KNIGHT STREET, SUITE 120
SHREVEPORT, LOUISIANA 71105
phone: 318-425-7452 fax: 318-425-4622 www.AFJMc.com
COPYRIGHT NOTICE:
THIS ENGINEERING DRAWING SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH AFJMC. NO
OTHER USE DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF AFJMC.
ALL COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.
TITLE 1-B 35%
21 MAY 2018
TITLE 1-B 65%
27 JUNE 2018
TITLE 1-B 95%
29 AUG. 2018
TITLE 1-B 100% 08 OCT. 2018
SCALE: 1"=100
E3
ELECTRICAL ENLARGED
TAXIWAY LIGHTING
PLAN
1. NEW RECESSED TAXIWAY EDGE LIGHT.
CONNECT TO ALERT TAXIWAY LIGHTING
CIRCUIT. REFERENCE KEY NOTE 3 FOR FIXTURE
DESCRIPTION. SAWCUT, BREAKOUT AND REMOVE
EXISTING PAVING FOR INSTALLATION OF NEW
FIXTURE CAN. EXTEND 2" DUCT FROM EXISTING
FIXTURE HANDHOLE TO NEW FIXTURE. REPLACE
PAVING AND MAKE AS NEW ON INSTALLATION OF
THE FIXTURE.
2. DIRECT BURY CABLE TO BE DEMO'D FROM
EXISTING MANHOLE/HANDHOLE TO EXISTING
FIXTURE HANDHOLE. PROVIDE NEW 2" DUCT WITH
#4 BARE CU COUNTERPOISE ABOVE FOR
EXTENSION OF NEW LIGHTING CIRCUIT PRIMARY
CABLE. SAWCUT, BREAKOUT AND REPLACE
EXISTING PAVING AS NEW, AS REQUIRED TO
INSTALL NEW DUCT.
3. NEW 12-INCH, LED, RECESSED TAXIWAY EDGE
LIGHT FIXTURE, FAA STYLE L-852T, TO REPLACE
EXISTING IN SAME LOCATION. NEW FIXTURES TO
BE PROVIDED WITH ARCTIC OPTION FOR DE-ICING.
UNLESS OTHERWISE NOTED, NEW FIXTURE TO BE
SUITABLE FOR INSTALLATION ON AN EXISTING
L-867B, 10.25" BOLT CIRCLE BASE. FIXTURE EQUAL
TO ADB SAFEGATE "ITEL-L-C-2-1-1"
4. EACH TAXIWAY LIGHT FIXTURE TO BE PROVIDED
WITH NEW FAA STYLE L-823, 30/45 WATT,
ISOLATION TRANSFORMER. PRIMARY CONNECTED
TO NEW, REPLACEMENT, #8 AWG, 5KV, EPR,
NON-SHIELDED PRIMARY CABLE. SECONDARY
CONNECTED TO TAXIWAY FIXTURE.
TRANSFORMER EQUAL TO ADB AIRFIELD
SOLUTIONS "RST-045-6-6-0"
5. UON, TAXIWAY LTG CIRCUIT CONDUCTORS ARE
ROUTED THRU EXISTING DUCT. ANY EXISTING
LIGHTING CIRCUITS WHICH ARE NOT BEING
REPLACED AS PART OF THIS PROJECT ARE TO
REMAIN, UNDISTURBED .
TAXIWAY EDGE LIGHT FIXTURES SHOWN ARE IN APPROXIMATE
LOCATIONS ONLY. THE PLAN DOES NOT ATTEMPT TO REPRESENT EXACT
LOCATIONS. FIELD VERIFY EXACT LOCATIONS AND MAKE ANY NECESSARY
ALLOWANCES FOR ADJUSTMENTS. UNLESS OTHERWISE NOTED AS A NEW
FIXTURE, ALL FIXTURES SHOWN ARE EXISTING.
TT
TT
TT
TT
ALL PRIMARY CABLE SPLICE CONNECTIONS, ISOLATION TRANSFORMER
CONNECTIONS-BOTH PRIMARY AND SECONDARY, AND TAXIWAY FIXTURE
CONNECTIONS ARE TO HAVE FULL-LENGTH HEAT SHRINK SEALING
PROTECTION APPLIED. HEAT SHRINK KIT EQUAL TO ADB AIRFIELD
SOLUTIONS PART NO. 71A0088-U.
VERIFY AND MARK-UP EXACT DUCT ROUTING, MANHOLES, AND CIRCUIT
ROUTING ON "AS-BUILT" PLANS.
REFERENCE SHEET E1 FOR CIRCUITING LEGEND.
B
FA4608-19-R-A011
Attachment 2 Drawings
AutoCAD SHX Text
ALPHA TAXIWAY
AutoCAD SHX Text
ALERT TAXIWAY
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
ENLARGED ALERT TAXIWAY LIGHTING PLAN
%%UELECTRICAL NOTES%%U:
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
TT
T
T
T
T
T
T
T
T
T
T
T
TTTT
T
T
T T
T
T
T
T
T
T
T
T
APPROX LOCATION OF
ILS HOLD LINE
APPROX LOCATION OF
VFR HOLD LINE
S
T
C
H
L
I
E
T
T
T
T
T
T
TYP.
TYP. UON.
2 3
TYP. UON.
EXISTING HANDHOLE
A
5 TYP.
A B
B
A B
A B
A B
A B
A B
A
A
7 B
B B
A
B
A
B
B
B
B
B
B
B
A
B
B
B
B
T
T
T
B
B
B
7 B
B
B
7 B
EXISTING TAXIWAY FIXTURE
HANDHOLE (TYP).
A
B 6
TYP.
B
A
B
A B
Drawing Number Facility Number
Project Number
PROJECT TITLE
SHEET
SHEET TITLE
OF
REVISION BY/DATE
Designer
Drafter
Project Manager
Date
Engineer Pavements Engineer Corrosion
Protective Engineer
Coating Engr.
Fire Chief
Operations Chief of
Construction
Roofing Management
COORDINATION
Computers
Engineer
Systems Security Police Security
Bioenvironmental
Airfield
Safety Ground Manager
Communication
APPROVED
SIGNATURE
Chief of Engineering
Design Chief of
Contracting
User
OFFICE
Engineer Civil
DESIGN FIRM
APRIL 2018
TITLE 1-A
16 APRIL 2018
GW
AIRFIELD
OP#1054124
REPAIR TAXIWAY LIGHTING &
CIRCUIT FACILITY
BARKSDALE AIR FORCE BASE,
LOUISIANA 71110
8E
DRAFTER
RKC
BARKSDALE
AIR FORCE BASE
LOUISIANA
ROBBIN K. CASSITY, P.E.
26059
THESE DRAWINGS DO NOT INCLUDE NECESSARY
COMPONENTS FOR CONSTRUCTION SAFETY.
18-016
ENGINEER:
LICENSE NO.
CONSULTING ENGINEERS
3003 KNIGHT STREET, SUITE 120
SHREVEPORT, LOUISIANA 71105
phone: 318-425-7452 fax: 318-425-4622 www.AFJMc.com
COPYRIGHT NOTICE:
THIS ENGINEERING DRAWING SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH AFJMC. NO
OTHER USE DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF AFJMC.
ALL COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.
TITLE 1-B 35%
21 MAY 2018
TITLE 1-B 65%
27 JUNE 2018
TITLE 1-B 95%
29 AUG. 2018
TITLE 1-B 100% 08 OCT. 2018
1" = 100"
E4
ELECTRICAL ENLARGED
TAXIWAY LIGHTING
PLAN
TAXIWAY EDGE LIGHT FIXTURES SHOWN ARE IN APPROXIMATE
LOCATIONS ONLY. THE PLAN DOES NOT ATTEMPT TO REPRESENT EXACT
LOCATIONS. FIELD VERIFY EXACT LOCATIONS AND MAKE ANY NECESSARY
ALLOWANCES FOR ADJUSTMENTS. UNLESS OTHERWISE NOTED AS A NEW
FIXTURE, ALL FIXTURES SHOWN ARE EXISTING.
TT
TT
1. DIRECT BURY CABLE TO BE DEMO'D FROM
EXISTING MANHOLE/HANDHOLE TO EXISTING
FIXTURE HANDHOLE. PROVIDE NEW 2" DUCT WITH
#4 BARE CU COUNTERPOISE ABOVE FOR
EXTENSION OF NEW LIGHTING CIRCUIT PRIMARY
CABLE. SAWCUT, BREAKOUT AND REPLACE
EXISTING PAVING AS NEW, AS REQUIRED TO
INSTALL NEW DUCT.
2. NEW 12-INCH, LED, RECESSED TAXIWAY EDGE
LIGHT FIXTURE, FAA STYLE L-852T, TO REPLACE
EXISTING IN SAME LOCATION. NEW FIXTURES TO
BE PROVIDED WITH ARCTIC OPTION FOR DE-ICING.
UNLESS OTHERWISE NOTED, NEW FIXTURE TO BE
SUITABLE FOR INSTALLATION ON AN EXISTING
L-867B, 10.25" BOLT CIRCLE BASE. FIXTURE EQUAL
TO ADB SAFEGATE "ITEL-L-C-2-1-1"
3. EACH TAXIWAY LIGHT FIXTURE TO BE PROVIDED
WITH NEW FAA STYLE L-823, 30/45 WATT,
ISOLATION TRANSFORMER. PRIMARY CONNECTED
TO NEW, REPLACEMENT, #8 AWG, 5KV, EPR,
NON-SHIELDED PRIMARY CABLE. SECONDARY
CONNECTED TO TAXIWAY FIXTURE.
TRANSFORMER EQUAL TO ADB AIRFIELD
SOLUTIONS "RST-045-6-6-0"
4. EXISTING TAXIWAY GUIDANCE SIGN TO REMAIN.
RECONNECT EXISTING SIGN ISOLATION XFMR TO
NEW ALPHA TAXIWAY LIGHTING CIRCUIT
CONDUCTOR.
5. DUCT EXISTING FROM HANDHOLE TO FIXTURE,
THIS LOCATION.
6. UON, TAXIWAY LTG CIRCUIT CONDUCTORS ARE
ROUTED THRU EXISTING DUCT. ANY EXISTING
LIGHTING CIRCUITS WHICH ARE NOT BEING
REPLACED AS PART OF THIS PROJECT ARE TO
REMAIN, UNDISTURBED .
7. PROVIDE NEW 3" DUCT EXTENDED FROM
EXISTING MANHOLE TO HANDHOLE AT TAXIWAY
FIXTURE/GUIDANCE SIGN. FIELD VERIFY NONE
EXISTING OR ALTERNATE EXISTING PATH FROM
MANHOLE AND DUCT SYSTEM TO ALERT TAXIWAY
LTG HANDHOLE/DUCT SYSTEM.
ALL PRIMARY CABLE SPLICE CONNECTIONS, ISOLATION TRANSFORMER
CONNECTIONS-BOTH PRIMARY AND SECONDARY, AND TAXIWAY FIXTURE
CONNECTIONS ARE TO HAVE FULL-LENGTH HEAT SHRINK SEALING
PROTECTION APPLIED. HEAT SHRINK KIT EQUAL TO ADB AIRFIELD
SOLUTIONS PART NO. 71A0088-U.
VERIFY AND MARK-UP EXACT DUCT ROUTING, MANHOLES, AND CIRCUIT
ROUTING ON "AS-BUILT" PLANS.
REFERENCE SHEET E1 FOR CIRCUITING LEGEND.
FA4608-19-R-A011
Attachment 2 Drawings
AutoCAD SHX Text
ALPHA TAXIWAY
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
ENLARGED ALPHA TAXIWAY LIGHTING PLAN
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
APPROX LOCATION OF
VFR HOLD LINE
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
F
F
F
F
F
F
EXISTING TAXIWAY FIXTURE
HANDHOLE (TYP).
F
F
F F
5F
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
APPROX LOCATION OF
VFR HOLD LINE
T
T
T
T
T
T
T
T
T
T
119A
C
C
C
C
C
C
C
EXISTING TAXIWAY FIXTURE
HANDHOLE (TYP).
T
C
C G
G
G
G
Drawing Number Facility Number
Project Number
PROJECT TITLE
SHEET
SHEET TITLE
OF
REVISION BY/DATE
Designer
Drafter
Project Manager
Date
Engineer Pavements Engineer Corrosion
Protective Engineer
Coating Engr.
Fire Chief
Operations Chief of
Construction
Roofing Management
COORDINATION
Computers
Engineer
Systems Security Police Security
Bioenvironmental
Airfield
Safety Ground Manager
Communication
APPROVED
SIGNATURE
Chief of Engineering
Design Chief of
Contracting
User
OFFICE
Engineer Civil
DESIGN FIRM
APRIL 2018
TITLE 1-A
16 APRIL 2018
GW
AIRFIELD
OP#1054124
REPAIR TAXIWAY LIGHTING &
CIRCUIT FACILITY
BARKSDALE AIR FORCE BASE,
LOUISIANA 71110
8E
DRAFTER
RKC
BARKSDALE
AIR FORCE BASE
LOUISIANA
ROBBIN K. CASSITY, P.E.
26059
THESE DRAWINGS DO NOT INCLUDE NECESSARY
COMPONENTS FOR CONSTRUCTION SAFETY.
18-016
ENGINEER:
LICENSE NO.
CONSULTING ENGINEERS
3003 KNIGHT STREET, SUITE 120
SHREVEPORT, LOUISIANA 71105
phone: 318-425-7452 fax: 318-425-4622 www.AFJMc.com
COPYRIGHT NOTICE:
THIS ENGINEERING DRAWING SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH AFJMC. NO
OTHER USE DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF AFJMC.
ALL COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.
TITLE 1-B 35%
21 MAY 2018
TITLE 1-B 65%
27 JUNE 2018
TITLE 1-B 95%
29 AUG. 2018
TITLE 1-B 100% 08 OCT. 2018
1" = 100"
E5
ELECTRICAL ENLARGED
TAXIWAY LIGHTING
PLAN
1" = 100"
TAXIWAY EDGE LIGHT FIXTURES SHOWN ARE IN APPROXIMATE
LOCATIONS ONLY. THE PLAN DOES NOT ATTEMPT TO REPRESENT EXACT
LOCATIONS. FIELD VERIFY EXACT LOCATIONS AND MAKE ANY NECESSARY
ALLOWANCES FOR ADJUSTMENTS. UNLESS OTHERWISE NOTED AS A NEW
FIXTURE, ALL FIXTURES SHOWN ARE EXISTING.
THE EXISTING FIXTURES SHOWN FOR TAXIWAY BRAVO HAVE ALREADY
BEEN REPLACED WITH LED FIXTURES AND ARE TO REMAIN. SCOPE OF
WORK FOR TAXIWAY BRAVO TO INCLUDE REPLACEMENT OF EXISTING
ISOLATION XFMRS AND CIRCUITING.
TTT
TTT
TTT
TTT
TTT
TTT
ALL PRIMARY CABLE SPLICE CONNECTIONS, ISOLATION TRANSFORMER
CONNECTIONS-BOTH PRIMARY AND SECONDARY, AND TAXIWAY FIXTURE
CONNECTIONS ARE TO HAVE FULL-LENGTH HEAT SHRINK SEALING
PROTECTION APPLIED. HEAT SHRINK KIT EQUAL TO ADB AIRFIELD
SOLUTIONS PART NO. 71A0088-U.
1. NEW RECESSED TAXIWAY EDGE LIGHT.
CONNECT TO ECHO 2 TAXIWAY LIGHTING
CIRCUIT. REFERENCE KEY NOTE 3 FOR FIXTURE
DESCRIPTION. SAWCUT, BREAKOUT AND REMOVE
EXISTING PAVING FOR INSTALLATION OF NEW
FIXTURE CAN. EXTEND 2" DUCT FROM EXISTING
FIXTURE HANDHOLE TO NEW FIXTURE. REPLACE
PAVING AND MAKE AS NEW ON INSTALLATION OF
THE FIXTURE.
2. NEW 12-INCH, LED, RECESSED TAXIWAY EDGE
LIGHT FIXTURE, FAA STYLE L-852T, TO REPLACE
EXISTING IN SAME LOCATION. NEW FIXTURES TO
BE PROVIDED WITH ARCTIC OPTION FOR DE-ICING.
UNLESS OTHERWISE NOTED, NEW FIXTURE TO BE
SUITABLE FOR INSTALLATION ON AN EXISTING
L-867B, 11.25" BOLT CIRCLE BASE. FIXTURE EQUAL
TO ADB SAFEGATE "ITEL-L-C-1-1-1"
3. EACH TAXIWAY LIGHT FIXTURE TO BE PROVIDED
WITH NEW FAA STYLE L-823, 30/45 WATT,
ISOLATION TRANSFORMER. PRIMARY CONNECTED
TO NEW, REPLACEMENT, #8 AWG, 5KV, EPR,
NON-SHIELDED PRIMARY CABLE. SECONDARY
CONNECTED TO TAXIWAY FIXTURE.
TRANSFORMER EQUAL TO ADB AIRFIELD
SOLUTIONS "RST-045-6-6-0"
4. EXISTING TAXIWAY GUIDANCE SIGN TO REMAIN.
RECONNECT EXISTING SIGN ISOLATION XFMR TO
ECHO 2/BRAVO TAXIWAY LIGHTING CIRCUIT
CONDUCTOR.
5. FIELD VERIFY EXISTING CONDUIT PATH FROM
MANHOLE AND DUCT SYSTEM TO TAXIWAY LTG.
HANDHOLE SYSTEM.
VERIFY AND MARK-UP EXACT DUCT ROUTING, MANHOLES, AND CIRCUIT
ROUTING ON "AS-BUILT" PLANS.
REFERENCE SHEET E1 FOR CIRCUITING LEGEND.
C G
FA4608-19-R-A011
Attachment 2 Drawings
AutoCAD SHX Text O
AutoCAD SHX Text
TRUE BEARING N 28 56'00'' W 300' X 11,756'
AutoCAD SHX Text
ECHO 2 TAXIWAY
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
BRAVO TAXIWAY
AutoCAD SHX Text
TRUE BEARING N 28 56'00'' W 300' X 11,756'
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
ENLARGED ECHO 2 TAXIWAY LIGHTING PLAN
AutoCAD SHX Text
ENLARGED BRAVO TAXIWAY LIGHTING PLAN
AutoCAD SHX Text
%%UELECTRICAL NOTES%%U:
AutoCAD SHX Text
T
T
T
T T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
E
E
E
E
E
E
E
E
E
E
T
T
E
E
E
E
E
E
E
E
E
E
T
T
2 3
TYP. UON.
T
C
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
APPROX LOCATION OF
VFR HOLD LINE
T
APPROX LOCATION OF
ILS HOLD LINE
TT
TT
T
2 3
TYP. UON.
E
E
E
E
E
E
E
E
EXISTING TAXIWAY FIXTURE
HANDHOLE (TYP).
7 E
E
E
6 E
Drawing Number Facility Number
Project Number
PROJECT TITLE
SHEET
SHEET TITLE
OF
REVISION BY/DATE
Designer
Drafter
Project Manager
Date
Engineer Pavements Engineer Corrosion
Protective Engineer
Coating Engr.
Fire Chief
Operations Chief of
Construction
Roofing Management
COORDINATION
Computers
Engineer
Systems Security Police Security
Bioenvironmental
Airfield
Safety Ground Manager
Communication
APPROVED
SIGNATURE
Chief of Engineering
Design Chief of
Contracting
User
OFFICE
Engineer Civil
DESIGN FIRM
APRIL 2018
TITLE 1-A
16 APRIL 2018
GW
AIRFIELD
OP#1054124
REPAIR TAXIWAY LIGHTING &
CIRCUIT FACILITY
BARKSDALE AIR FORCE BASE,
LOUISIANA 71110
8E
DRAFTER
RKC
BARKSDALE
AIR FORCE BASE
LOUISIANA
ROBBIN K. CASSITY, P.E.
26059
THESE DRAWINGS DO NOT INCLUDE NECESSARY
COMPONENTS FOR CONSTRUCTION SAFETY.
18-016
ENGINEER:
LICENSE NO.
CONSULTING ENGINEERS
3003 KNIGHT STREET, SUITE 120
SHREVEPORT, LOUISIANA 71105
phone: 318-425-7452 fax: 318-425-4622 www.AFJMc.com
COPYRIGHT NOTICE:
THIS ENGINEERING DRAWING SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH AFJMC. NO
OTHER USE DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF AFJMC.
ALL COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.
TITLE 1-B 35%
21 MAY 2018
TITLE 1-B 65%
27 JUNE 2018
TITLE 1-B 95%
29 AUG. 2018
TITLE 1-B 100% 08 OCT. 2018
1" = 100"
E6
ELECTRICAL ENLARGED
TAXIWAY LIGHTING
PLAN
1" = 100"
TAXIWAY EDGE LIGHT FIXTURES SHOWN ARE IN APPROXIMATE
LOCATIONS ONLY. THE PLAN DOES NOT ATTEMPT TO REPRESENT EXACT
LOCATIONS. FIELD VERIFY EXACT LOCATIONS AND MAKE ANY NECESSARY
ALLOWANCES FOR ADJUSTMENTS. UNLESS OTHERWISE NOTED AS A NEW
FIXTURE, ALL FIXTURES SHOWN ARE EXISTING.
INDICATES AN ELEVATED
TAXIWAY LIGHT FIXTURE
T
E
TTT
TTT
TTT
TTT
TTT
TTT
TTT
TTT
TTT
TTT
TTT
TTT
TTT
TTT
1. NEW RECESSED TAXIWAY EDGE LIGHT.
CONNECT TO DELTA TAXIWAY LIGHTING
CIRCUIT. REFERENCE KEY NOTE 3 FOR FIXTURE
DESCRIPTION. SAWCUT, BREAKOUT AND REMOVE
EXISTING PAVING FOR INSTALLATION OF NEW
FIXTURE CAN. EXTEND 2" DUCT FROM EXISTING
FIXTURE HANDHOLE TO NEW FIXTURE. REPLACE
PAVING AND MAKE AS NEW ON INSTALLATION OF
THE FIXTURE.
2. NEW 12-INCH, LED, RECESSED TAXIWAY EDGE
LIGHT FIXTURE, FAA STYLE L-852T, TO REPLACE
EXISTING IN SAME LOCATION. NEW FIXTURES TO
BE PROVIDED WITH ARCTIC OPTION FOR DE-ICING.
UNLESS OTHERWISE NOTED, NEW FIXTURE TO BE
SUITABLE FOR INSTALLATION ON AN EXISTING
L-867B, 10.25" BOLT CIRCLE BASE. FIXTURE EQUAL
TO ADB SAFEGATE "ITEL-L-C-2-1-1"
3. EACH TAXIWAY LIGHT FIXTURE TO BE PROVIDED
WITH NEW FAA STYLE L-823, 30/45 WATT,
ISOLATION TRANSFORMER. PRIMARY CONNECTED
TO NEW, REPLACEMENT, #8 AWG, 5KV, EPR,
NON-SHIELDED PRIMARY CABLE. SECONDARY
CONNECTED TO TAXIWAY FIXTURE.
TRANSFORMER EQUAL TO ADB AIRFIELD
SOLUTIONS "RST-045-6-6-0"
4. NEW FAA STYLE L-86IT(L), ELEVATED LED, 14"
HIGH, TAXIWAY EDGE LIGHT FIXTURE TO REPLACE
EXISTING IN SAME LOCATION. NEW FIXTURES TO
BE PROVIDED WITH ARCTIC OPTION FOR DE-ICING.
FIELD VERIFY EXISTING BASE COUPLING SIZE AND
TYPE. FIXTURE EQUAL TO ADB SAFEGATE
"ETES-L-6-*-1-1".
5. EXISTING TAXIWAY GUIDANCE SIGN TO REMAIN.
RECONNECT EXISTING SIGN ISOLATION XFMR TO
CHARLIE/DELTA TAXIWAY LIGHTING CIRCUIT
CONDUCTOR.
6. FIELD VERIFY EXISTING CONDUIT PATH FROM
MANHOLE AND DUCT SYSTEM TO TAXIWAY LTG
HANDHOLE SYSTEM.
7. DIRECT BURY CABLE TO BE DEMO'D FROM
EXISTING MANHOLE/HANDHOLE TO EXISTING
FIXTURE HANDHOLE. PROVIDE NEW 2" DUCT WITH
#4 BARE CU COUNTERPOISE ABOVE FOR
EXTENSION OF NEW LIGHTING CIRCUIT PRIMARY
CABLE. SAWCUT, BREAKOUT AND REPLACE
EXISTING PAVING AS NEW, AS REQUIRED TO
INSTALL NEW DUCT.
ALL PRIMARY CABLE SPLICE CONNECTIONS, ISOLATION TRANSFORMER
CONNECTIONS-BOTH PRIMARY AND SECONDARY, AND TAXIWAY FIXTURE
CONNECTIONS ARE TO HAVE FULL-LENGTH HEAT SHRINK SEALING
PROTECTION APPLIED. HEAT SHRINK KIT EQUAL TO ADB AIRFIELD
SOLUTIONS PART NO. 71A0088-U.
VERIFY AND MARK-UP EXACT DUCT ROUTING, MANHOLES, AND CIRCUIT
ROUTING ON "AS-BUILT" PLANS.
REFERENCE SHEET E1 FOR CIRCUITING LEGEND.
FA4608-19-R-A011
Attachment 2 Drawings
AutoCAD SHX Text
CHARLIE TAXIWAY
AutoCAD SHX Text
TAXIWAY
AutoCAD SHX Text
INDIA
AutoCAD SHX Text
AutoCAD SHX Text
TAXIWAY
AutoCAD SHX Text
DELTA
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
ENLARGED CHARLIE TAXIWAY LIGHTING PLAN
AutoCAD SHX Text
ENLARGED DELTA TAXIWAY LIGHTING PLAN
T
T
T
T
T
T
T
T
T
T
T
T
T
T
S
T
C
H
L
I
E
E
T
T
T
T
T
T
T
1 2
TYP. UON.
T
EXISTING TAXIWAY FIXTURE
HANDHOLE (TYP).
G
G
G
T
T
T
T
T
T
T
T
T
T
T
S
T
C
H
L
I
E
E
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
E
E
E
E
E
E
E
E
E
E
T
T
T
T
E
E
E
E
E
E
E
E
E
E
T
T
G
G
Drawing Number Facility Number
Project Number
PROJECT TITLE
SHEET
SHEET TITLE
OF
REVISION BY/DATE
Designer
Drafter
Project Manager
Date
Engineer Pavements Engineer Corrosion
Protective Engineer
Coating Engr.
Fire Chief
Operations Chief of
Construction
Roofing Management
COORDINATION
Computers
Engineer
Systems Security Police Security
Bioenvironmental
Airfield
Safety Ground Manager
Communication
APPROVED
SIGNATURE
Chief of Engineering
Design Chief of
Contracting
User
OFFICE
Engineer Civil
DESIGN FIRM
APRIL 2018
TITLE 1-A
16 APRIL 2018
GW
AIRFIELD
OP#1054124
REPAIR TAXIWAY LIGHTING &
CIRCUIT FACILITY
BARKSDALE AIR FORCE BASE,
LOUISIANA 71110
8E
DRAFTER
RKC
BARKSDALE
AIR FORCE BASE
LOUISIANA
ROBBIN K. CASSITY, P.E.
26059
THESE DRAWINGS DO NOT INCLUDE NECESSARY
COMPONENTS FOR CONSTRUCTION SAFETY.
18-016
ENGINEER:
LICENSE NO.
CONSULTING ENGINEERS
3003 KNIGHT STREET, SUITE 120
SHREVEPORT, LOUISIANA 71105
phone: 318-425-7452 fax: 318-425-4622 www.AFJMc.com
COPYRIGHT NOTICE:
THIS ENGINEERING DRAWING SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH AFJMC. NO
OTHER USE DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF AFJMC.
ALL COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.
TITLE 1-B 35%
21 MAY 2018
TITLE 1-B 65%
27 JUNE 2018
TITLE 1-B 95%
29 AUG. 2018
TITLE 1-B 100% 08 OCT. 2018
1" = 100"
E7
ELECTRICAL ENLARGED
TAXIWAY LIGHTING
PLAN
TAXIWAY EDGE LIGHT FIXTURES SHOWN ARE IN APPROXIMATE
LOCATIONS ONLY. THE PLAN DOES NOT ATTEMPT TO REPRESENT EXACT
LOCATIONS. FIELD VERIFY EXACT LOCATIONS AND MAKE ANY NECESSARY
ALLOWANCES FOR ADJUSTMENTS. UNLESS OTHERWISE NOTED AS A NEW
FIXTURE, ALL FIXTURES SHOWN ARE EXISTING.
TT
TT
TTT
TTT
TTT
TTT
TTT
TTT
TTT
1.. NEW 12-INCH, LED, RECESSED TAXIWAY EDGE
LIGHT FIXTURE, FAA STYLE L-852T, TO REPLACE
EXISTING IN SAME LOCATION. NEW FIXTURES TO
BE PROVIDED WITH ARCTIC OPTION FOR DE-ICING.
UNLESS OTHERWISE NOTED, NEW FIXTURE TO BE
SUITABLE FOR INSTALLATION ON AN EXISTING
L-867B, 10.25" BOLT CIRCLE BASE. FIXTURE EQUAL
TO ADB SAFEGATE "ITEL-L-C-2-1-1"
2. EACH TAXIWAY LIGHT FIXTURE TO BE PROVIDED
WITH NEW FAA STYLE L-823, 30/45 WATT,
ISOLATION TRANSFORMER. PRIMARY CONNECTED
TO NEW, REPLACEMENT, #8 AWG, 5KV, EPR,
NON-SHIELDED PRIMARY CABLE. SECONDARY
CONNECTED TO TAXIWAY FIXTURE.
TRANSFORMER EQUAL TO ADB AIRFIELD
SOLUTIONS "RST-045-6-6-0"
ALL PRIMARY CABLE SPLICE CONNECTIONS, ISOLATION TRANSFORMER
CONNECTIONS-BOTH PRIMARY AND SECONDARY, AND TAXIWAY FIXTURE
CONNECTIONS ARE TO HAVE FULL-LENGTH HEAT SHRINK SEALING
PROTECTION APPLIED. HEAT SHRINK KIT EQUAL TO ADB AIRFIELD
SOLUTIONS PART NO. 71A0088-U.
VERIFY AND MARK-UP EXACT DUCT ROUTING, MANHOLES, AND CIRCUIT
ROUTING ON "AS-BUILT" PLANS.
REFERENCE SHEET E1 FOR CIRCUITING LEGEND.
TT
G
G
FA4608-19-R-A011
Attachment 2 Drawings
AutoCAD SHX Text
LS6654
AutoCAD SHX Text
OWS6653
AutoCAD SHX Text
APRON
AutoCAD SHX Text
PARKING
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
CHARLIE TAXIWAY
AutoCAD SHX Text
TAXIWAY
AutoCAD SHX Text
INDIA
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
ENLARGED PARALLEL TAXIWAY LIGHTING PLAN
AutoCAD SHX Text
%%UELECTRICAL NOTES%%U:
AutoCAD SHX Text
| Sheets and Views |
| T1-Title Sheet |
| E1 General Notes and Details |
| E2 Electrical Site Plan |
| E3 Enlarged Lighting Plan |
| E4 Enlarged Lighting Plan |
| E5 Enlarged Lighting Plan |
| E6 Enlarged Lighting Plan |
| E7 Enlarged Lighting Plan |
File details come from the government source that posted it.