This document is a Questions and Answers (Q&A) file related to a federal contract opportunity for a Breathing Air Compressor. The key details are:

The required compressor size is 27 CFM, with a 3-phase 480V power source and 60Hz frequency. The maximum working pressure required is 6000 PSI, and the agency needs an auto-stop feature. The compressor will be used with a Mako SCFS2 - 4HP fill station. The room dimensions are 17' x 34', with a 69 1/2" wide doorway. The agency requires bottles that do not need hydro testing and attached storage. A forklift will be provided as needed, and the contractor must provide a certified electrician. The agency requires both a user manual and on-site training as part of the installation and instruction requirements.

The related federal contract opportunity is Solicitation Number FA460024Q0016 for a Breathing Air Compressor, issued by the Department of the Air Force Air Combat Command.

View the file

Other files for this federal contract opportunity

Other files attached to Breathing Air Compressor, newest first.
File Type Posted
20240517_094150.jpg JPG image
20240517_094349.jpg JPG image
COMBO - FA460024Q0016 - Amendment 00003.pdf PDF
20240517_094222.jpg JPG image
20240517_094232.jpg JPG image
20240517_094253.jpg JPG image
COMBO - FA460024Q0016 - Amendment 00002.pdf PDF
Pre- Bid NCIC Screening and Pass Request - Template.pdf PDF
COMBO - FA460024Q0016 - Amendment 0001.pdf PDF
COMBO - FA460024Q0016.pdf PDF
Statement Of Need - Fire Dept Air Compressor.docx DOCX document
Show all 11

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Q&A for Fire Dept Breathing Air Compressor Q1: What size compressor do you want?

27 CFM

Q2: What power source are you planning to use? Do you require:

- Single-phase 115V or 230V?

- Three-phase 230V, 400V, or 440V?

3 PHASE 480V

Q3: Do you need a frequency of 50Hz or 60Hz?

60 HZ

Q4: What is the maximum working pressure required?

6000 PSI

Q5: Will they need an Auto-Stop?

YES

Q6: What fill station will you be using with this?

MAKO SCFS2 – 4HP

Q7: Could you provide pictures and video of the room?

PICTURE ATTACHED

Q8: Dims of the room?

17’ X 34’ Q9: Width of the doorway (need a minimum 36 inches) 69 1/2 Q10: Do you want bottles that don’t need to be hydro tested

YES

Q11: Are we going to have an attached storage

YES

Q12: Please take picture of old compressor with the air tank line coming in

PICTURE ATTACHED

Q13: Will a forklift be provided to move equipment if needed?

We are able to provide a forklift with advance notice of the install.

Q14: In the Performance Work Statement (PWS), there is a requirement to provide "Installation and Instruction on operation." Could you please elucidate whether this entails providing a comprehensive user manual or conducting on-site training sessions?

We require both a user manual and on-site training.

Q15: Will a certified electrician be available, or will one need to be provided?

The contractor will need to provide the electrician.