Amendment 0004 - Questions and Answers - Breathing Air Compressor.docx

DOCX document 14 KB Posted

Attached to
Breathing Air Compressor
Solicitation number
FA460024Q0016
Issued by

About this file

This document is a Questions and Answers (Q&A) file related to a federal contract opportunity for a Breathing Air Compressor. The key details are:

The required compressor size is 27 CFM, with a 3-phase 480V power source and 60Hz frequency. The maximum working pressure required is 6000 PSI, and the agency needs an auto-stop feature. The compressor will be used with a Mako SCFS2 - 4HP fill station. The room dimensions are 17' x 34', with a 69 1/2" wide doorway. The agency requires bottles that do not need hydro testing and attached storage. A forklift will be provided as needed, and the contractor must provide a certified electrician. The agency requires both a user manual and on-site training as part of the installation and instruction requirements.

The related federal contract opportunity is Solicitation Number FA460024Q0016 for a Breathing Air Compressor, issued by the Department of the Air Force Air Combat Command.

View the file

Other files

File Type Posted
COMBO - FA460024Q0016 - Amendment 00003.pdf PDF
20240517_094222.jpg JPG image
20240517_094150.jpg JPG image
20240517_094349.jpg JPG image
20240517_094232.jpg JPG image
20240517_094253.jpg JPG image
COMBO - FA460024Q0016 - Amendment 00002.pdf PDF
Pre- Bid NCIC Screening and Pass Request - Template.pdf PDF
COMBO - FA460024Q0016 - Amendment 0001.pdf PDF
Statement Of Need - Fire Dept Air Compressor.docx DOCX document
COMBO - FA460024Q0016.pdf PDF
Show all 11

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Q&A for Fire Dept Breathing Air Compressor Q1: What size compressor do you want?

27 CFM

Q2: What power source are you planning to use? Do you require:

- Single-phase 115V or 230V?

- Three-phase 230V, 400V, or 440V?

3 PHASE 480V

Q3: Do you need a frequency of 50Hz or 60Hz?

60 HZ

Q4: What is the maximum working pressure required?

6000 PSI

Q5: Will they need an Auto-Stop?

YES

Q6: What fill station will you be using with this?

MAKO SCFS2 – 4HP

Q7: Could you provide pictures and video of the room?

PICTURE ATTACHED

Q8: Dims of the room?

17’ X 34’ Q9: Width of the doorway (need a minimum 36 inches) 69 1/2 Q10: Do you want bottles that don’t need to be hydro tested

YES

Q11: Are we going to have an attached storage

YES

Q12: Please take picture of old compressor with the air tank line coming in

PICTURE ATTACHED

Q13: Will a forklift be provided to move equipment if needed?

We are able to provide a forklift with advance notice of the install.

Q14: In the Performance Work Statement (PWS), there is a requirement to provide "Installation and Instruction on operation." Could you please elucidate whether this entails providing a comprehensive user manual or conducting on-site training sessions?

We require both a user manual and on-site training.

Q15: Will a certified electrician be available, or will one need to be provided?

The contractor will need to provide the electrician.

File details come from the government source that posted it. Updated .