A B C D E F
MAINTENANCE AND REPAIR OF BUILDINGS
FACILITIES AND STUCTURES AT JOINT BASE MCGUIRE-DIX-LAKEHURST (JB MDL)
PERFORMANCE PERIOD BASE YEAR
The Contractor shall furnish all plant, labor, equipment, tools, supplies and materials and perform all work necessary to perform maintenance and repair of buildings, facilities and stuctures at JB MDL , NJ in accordance with attached specifications period of 20 Sep 15 TO 19 Sep 16
0002 INFORMATION CLIN QTY UNIT COST TOTAL
0002AA Replace and paint wood interior, flush solid door 2'-8" x 6'-8" thur 7'-0"
0002AB Complete as above 20 EA ________ ___________ 0002AC Complete as above, with vision lights. Max 12SF of glass area 15 EA ________ ___________
0002AD Complete as above with louvers to match existing or measure 10" or less than width of door and have a max height of 48" 15 EA ________ ___________
0002AE Complete as above B Label fire (90 min) rated door 15 EA ________ ___________
0003 INFORMATION CLIN
0003AA Replace and paint wood interior, flush solid door 3'-0" X 6'-8" thur 7'-3"
0003AB Complete as above 20 EA ________ ___________ 0003AC Complete as above, with vision lights Max 12 SF of glass area 15 EA ________ ___________
0003AD
Complete as above, with louvers to match existing or to measure 10" or less than with width of door and have a max louver height of 48"
15 EA ________ ___________
0003AE Complete as above B Label fire (90 min) rated door 15 EA ________ ___________
0003AF Replace and paint wood interior, flush solid Dutch doors 3'-0" x 6'- 8" thur 7'-3" 15 EA ________ ___________
METAL DOORS - INTERIOR
0004 INFORMATION CLIN
A B C D E F
0004AA Replace and paint metal interior flush door 2'-6" x 6'-8" thur 7'-3"
0004AB Complete as above 20 EA ________ ___________ 0004AC Complete as above, with vision lights Max 12 SF of glass area 15 EA ________ ___________
0004AD
Complete as above, with louvers to match existing or to measure 10" or less than with width of door and have a max louver height of 48"
15 EA ________ ___________
0004AE Complete as above B Label fire (90 min) rated door 15 EA ________ ___________
0005 INFORMATION CLIN
0005AA Replace and paint metal interior flush door 2'- 8" X 6'- 8" thur 8'-0"
0005AB Complete as above 20 EA ________ ___________ 0005AC Complete as above, with vision lights Max 12 SF of glass area 15 EA ________ ___________
0005AD
Complete as above, with louvers to match existing or to measure 10" or less than with width of door and have a max louver height of 48"
15 EA ________ ___________
0005AE Complete as above B Label fire (90 min) rated door 15 EA ________ ___________
0006 INFORMATION CLIN
0006AA Replace and paint metal interior door 3' - 0" x 6' - 8" thur 8' - 0" 0006AB Complete as above 20 EA ________ ___________
0006AC Complete as above, metal clad door with vision lights, max 12 SF glass area 15 EA ________ ___________
0006AD
Complete as above, with louvers to match existing or to measure 10" or less than with width of door and have a max louver height of 48"
15 EA ________ ___________
0006AE Complete as above B Label fire (90 min) rated door 15 EA ________ ___________
METAL DOORS - EXTERIOR
0007 INFORMATION CLIN
0007AA Replace and paint metal exterior door 2'-6" x 6'-8" thur 8'-0" 0007AB Complete as above 20 EA ________ ___________
0007AC Complete as above, metal clad door with vision lights, max 12 SF glass area 15 EA ________ ___________
A B C D E F
0007AD
Complete as above, with louvers to match existing or to measure 10" or less than with width of door and have a max louver height of 48"
15 EA ________ ___________
0007AE Complete as above B Label fire (90 min) rated door 15 EA ________ ___________
0008 INFORMATION CLIN
0008AA Replace and paint metal exterior door 2'-8" X 6'-8" thur 8'-0" 0008AB Complete as above 20 EA ________ ___________
0008AC Complete as above, metal clad door with vision lights, max 12 SF glass area 15 EA ________ ___________
0008AD
Complete as above, with louvers to match existing or to measure 10" or less than with width of door and have a max louver height of 48"
15 EA ________ ___________
0008AE Complete as above B Label fire (90 min) rated door 15 EA ________ ___________
0009 INFORMATION CLIN
0009AA Replace and paint metal exterior door 3'-0" x 6'-8" thur 8'-0" 0009AB Complete as above 30 EA ________ ___________
0009AC Complete as above, metal clad door with vision lights, max 12 SF glass area 20 EA ________ ___________
0009AD
Complete as above, with louvers to match existing or to measure 10" or less than with width of door and have a max louver height of 48"
20 EA ________ ___________
0009AE Complete as above B Label fire (90 min) rated door 20 EA ________ ___________
0010 INFORMATION CLIN
0010AA Replace and paint metal exterior door 3'-4" x 6'-8" thru 8'-0" 0010AB Complete as above 20 EA ________ ___________
0010AC Complete as above, metal clad door with vision lights, max 12 SF glass area 15 EA ________ ___________
0010AD
Complete as above, with louvers to match existing or to measure 10" or less than with width of door and have a max louver height of 48"
15 EA ________ ___________
0010AE Complete as above B Label fire (90 min) rated door 15 EA ________ ___________
0011 INFORMATION CLIN
A B C D E F 0011AA Replace & paint 3'0" x 9'0" metal exterior flush door 0011AB Complete as above. 15 EA ________ ___________
0011AC Complete as above with louvers to match (top & bottom) if applicable 15 EA ________ ___________
0011AD Complete as above B Label fire (90 min) rated door 15 EA ________ ___________
METAL DOOR FRAMES
0012 Replace/paint single metal door frame, interior and exterior, B label fire (90min) rated maximum size 4'-0" x 8'-0"
25 EA ________ ___________
0013 Replace/paint single metal door frame, interior and exterior, B label fire (90min) rated maximum size 8'-0" x 8'-0"
25 EA ________ ___________
0014 Replace/paint single metal door frame, head and transom casings and stops as applicalbe maximum size 4'-0" X 8'-0" 20 EA ________ ___________
0015 Replace / paint double metal door frame, head and transom casings and stops as applicable maximum size 8' - 0" X 8' - 0" 20 EA ________ ___________
WOOD DOOR FRAMES
0016 Replace/paint single wood door frame, including casing and stops as applicable (maximum size 4'-0" X 8'-0") 20 EA ________ ___________
0017 Replace / paint double wood door frame, including casings and stops as applicable (maximum size 8' - 0" X 8' - 0") 20 EA ________ ___________
WOOD DOOR CASINGS/STOPS
0018 INFORMATION CLIN
0018AA Replace and paint wood door casing
0018AB
Replace and paint wood single door casing clam shell type, maximum 11/16" x 2 1/4" single door openings (one side) size up to 4'-0" x 8'-0"
20 EA ________ ___________
A B C D E F
0018AC
Replace and paint wood single door casing clam shell type, maximum 11/16" x 2 1/4" single door openings (one side) size up to 8'-0" x 8'-0"
20 EA ________ ___________
0019 INFORMATION CLIN
0019AA Replace and paint wood door stops
0019AB Replace and paint wood door stops complete set for single wood door maximum size 4'-0"x 8'-0" 15 EA ________ ___________
0019AC Replace and paint wood door stops complete set for double wood door maximum size 8'-0"x 8'-0" 15 EA ________ ___________
0020 INFORMATION CLIN
0020AA Replace and paint door louvers 0020AB Replace and paint wood door louvers Maximum 6 SF 15 EA ________ ___________ 0020AC Replace and paint metal door louvers Maximum 6 SF 15 EA ________ ___________
0021 INFORMATION CLIN
0021AA Refit Doors
0021AB Refit interior wood single door and adjust hardware for proper operation 15 EA ________ ___________
0021AC Refit interior wood double doors and asdjust hardwaer for proper operation 15 EA ________ ___________
0021AD Refit interior stairwell single wood or metal fire door and adjust hardware 15 EA ________ ___________
0021AE Refit interior stairwell double wood or metal fire door and adjust hardware for proper 15 EA ________ ___________
0021AF Refit exterior single wood or metal door and adjust hardware for proper operation 15 EA ________ ___________
0021AG Refit exterior wood or metal double door and adjust hardware for proper operation 15 EA ________ ___________
0021AH Refit exterior mechanical room metal double door and adjust for proper operation
15 EA ________ ___________
0022 INFORMATION CLIN
0022AA Replace entrance and store front door, includes trim and hardware, temperd glass
A B C D E F 0022AB Entrance front doors 3'-0" x 7'-0" Entrance Door Full 10 EA ________ ___________ 0022AC Entrance front doors 6'-0" x 7'-0" 1/2 Entrance Door Full 10 EA ________ ___________ 0022AD Entrance front doors 5'-0" x 7'-0" 1/2 Entrance Door Full 10 EA ________ ___________
0023 INFORMATION CLIN
0023AA Install automatic door openers for store front doors 0023AB Complete as above, slider single 10 EA ________ ___________ 0023AC Complete as above, slider double 10 EA ________ ___________ 0023AD Complete as above, swinging single 10 EA ________ ___________ 0023AE Complete as above, swinging double 15 EA ________ ___________
HARDWARE - HEAVY DOORS
0024 INFORMATION CLIN
0024AA Replace mortise type lock set and keeper regular keying 0024AB Medium Duty type 15 EA ________ ___________ 0024AC Heavy Duty type 15 EA ________ ___________
0025 Replace cylindrical type latch set (passage) and keeper 20 EA ________ ___________
0026 INFORMATION CLIN
0026AA Replace aluminum threshold for door 0026AB wood or metal door {Maximum size 3'} 13 EA ________ ___________ 0026AC wood or metal door {Maximum size 6'} 13 EA ________ ___________
0027 INFORMATION CLIN
0027AA
Replace exit or panic device stainless steel or bronze as specified single door complete rim exit bolt includes pull with thumb piece and cylinder lock
30 EA ________ ___________
0028 Replace surface mounted door closer as required with regular arm Interior and exterior wood or metal doors 30 EA ________ ___________
A B C D E F
Replace full mortise hinges, ball bearing, extra heavy weight, non rising pin, size up and including 5" x 5" with steel pins, complete includimg screews steel pins
30 EA ________ ___________
Remove existing hinges and install extuded hinge, andodized aluminum geared continuous hinge, thrust bearing, heavy weight,unhandled with finish as required (half surface)
30 EA ________ ___________
Remove existing hinges and install extuded andodized aluminum geared continuous hinge, thrust bearing, heavy weight,unhandled with finish as required (half surface)
30 EA ________ ___________
Replace surface mounted foot bolt zinc plated steel bolt,maximum length 6" 20 EA ________ ___________
Replace surface mounted chain bolt zinc plated steel bolt, maximum length 6" 20 EA ________ ___________
0034 Replace floor mounted door stop, Aluminum 15 EA ________ ___________
0035 INFORMATION CLIN
0035AA Replace door holder, Aluminum 0035AB Floor Mounted 15 EA ________ ___________ 0035AC Door Mounted 15 EA ________ ___________
Replace astragal strip on double doors metal or wood (as applicable) 15 EA ________ ___________
Replace threshold weather stripping door sweep, extruded aluminum slotted holes, with screws 15 EA ________ ___________
0038 INFORMATION CLIN
0038AA Replace kick plate, size 10" x 30" thru 38" 0038AB Replace kick plate, size 10" x 30" thru 38" Aluminum 10 EA ________ ___________ 0038AC Replace kick plate, size 10" x 30" thru 38" Plastic 10 EA ________ ___________
A B C D E F
0039 Replace push plate on door, .050 thick 4" x 16" aluminum 10 EA ________ ___________
0040 Replace combination push-pull plates on doors
0040AA
Replace combination push-pull plate on doors thick 4" x 16" Bronze 20 EA ________ ___________
0040AB
Replace combination push-pull plate on doors thick 4" x 16" Aluminum 20 EA ________ ___________
Wire Glass Replace wire glass (1/4 thick polished clear in door maximum 10 SF 20 EA ________ ___________
CARPENTRY
0042 INFORMATION CLIN
0042AA Replace paint Gypsum and Paperless wall board
0042AB
Replace and paint Gypsum board wall board including taping, three coat of spacklling, one coat of primer paint and two finish coat of paint 1" x 4' x 8' minimum 4' x 4'
12,000 SF ________ ___________
0042AC As above, fire rated Fire rating of 5/8 " 1 hour 6,000 SF ________ ___________
0042AD
Replace & paint Paperless moisture and mold resistant wall board 1/2 x 4' x 8' DensAmor Plus or Equivilent (minmum 4' x 4') 12,000 SF ________ ___________
0043 Plaster Repair & paint gypsum plaster (on metal, tysum lath or masonry surface 2,000 SF ________ ___________
0044 Wood Base Replace & paint 1" x 6" wood base minimum 5 LF 600 LF ________ ___________
0045 Shoe Molding Replace & paint or finish shoe molding as required to match existing Minimum 5 LF 600 LF ________ ___________
EXTERIOR LUMBER
0046 INFORMATION CLIN
A B C D E F
0046AA
Exterior Lumber Replace & paint 1" x 4" exposed exterior lumber (minimum 5 LF) 300 LF ________ ___________
0046AB
Exterior Lumber Replace & paint 1" x 6" exposed exterior lumber (minimum 5 LF) 600 LF ________ ___________
0046AC
Exterior Lumber Replace & paint 2" x 4" exposed exterior lumber (minimum 5 LF) 600 LF ________ ___________
0046AD
Exterior Lumber Replace & paint 2" x 6" exposed exterior lumber (minimum 5 LF) 400 LF ________ ___________
0046AE
Exterior Lumber Replace & paint 2" x 8" exposed exterior lumber (minimum 5 LF) 300 LF ________ ___________
0046AF
Exterior Lumber Replace & paint 2" x 10" exposed exterior lumber (minimum 5 LF) 200 LF ________ ___________
0046AG
Exterior Lumber Replace & paint 2" x 12" exposed exterior lumber (minimum 5 LF) 200 LF ________ ___________
0047 INFORMATION CLIN
0047AA Wood Siding
0047AB
Replace & paint exterior vertical wood siding to match existing (minimum 8sf) nominal size 1" x 8" 100 SF ________ ___________
0047AC Plywood - 5/8" T 111 Exterior Siding for use on shed doors in compliance with section 09550 of the specification 360 SF ________ ___________
0048 INFORMATION CLIN
0048AA Remove, dispose and install new plywood:
0048AB Replace Plywood 1/4" 500 SF ________ ___________ 0048AC Replace Plywood 1/2" 500 SF ________ ___________ 0048AD Replace plywood 3/4" 8,000 SF ________ ___________
KITCHEN CABINETS & COUNTER TOP UPH UNITS
0049 Cabinet / Kitchen Wall remove and replace upper kitchen cabinets with new wood cabinet to comform with existing configuration. 200 LF ________ ___________
A B C D E F
0050 Cabinet / Kitchen Base remove and replace base kitchen cabinets with new wood cabinets to comform with existing configuration 200 LF ________ ___________
Counter Top / Replace - replace complete counter top with Formica Laminate top, provide necessary end caps and cutout for kitchen sink in compliance with section 11450 of the specification
300 LF ________ ___________
0052 Edge Strip / Formic Laminate - replace edge strip tomatch existing in compliance with section 11450 of the specification 100 EA ________ ___________
MEDICINE CABINETS
0053 INFORMATION CLIN
0053AA Replace Medicine Cabinet
0053AB Cabinet / Medicine - replace to match existing size in compliance with section 10800 of the specification 15 EA ________ ___________
0053AC Cabinet / Medicine With Fluorescent Lights - replace to match existing size in compliance with section 10800 of the specification 15 EA ________ ___________
DOORS & MISC ITEMS (UPH) UNITS
0054 Threshold / Marble - replace marble threshold 15 EA ________ ___________
0055 Rod / Shower Curtain - replace to match existing shape and size 10 EA ________ ___________
ELECTRICAL MISC ITEMS (UPH) UNITS
0056 Smoke Detector / AC with built in battery backup 20 EA ________ ___________
0057 Exhaust Fan / Bathroom ceiling, 80 CFM with light - replace 20 EA ________ ___________
A B C D E F
0058 Range Hood / Kitchen with Light - Replace existing range hood with color and size to match existing 15 EA ________ ___________
0059 INFORMATION CLIN
0059AA Replace Thermostat
0059AB Thermostat / Programmable digital readout for heating and cooling -replace 30 EA ________ ___________
PLUMBING - BATHROOM & KITCHEN ITEMS (UPH) UNITS
0060 Tub / Steel Recessed, White, 5' x 30" - replace 12 EA ________ ___________
0061 Shower Base / Fiberglass, White - replace with 30" x 30" minimum to 36: x 36" maximum includes strainer 12 EA ________ ___________
0062 Shower Valve - Replace with Chrome Finish Pressure balanced, single lever scald guerd with adjustable temperature limit stop 15 EA ________ ___________
Trip Waste / Toe Operated Brass, 1 1/2" - replace trip waste and overflow to include chrome face plate in compliance with section 15400 of the specification
15 EA ________ ___________
0064 Face Plate / Chrome - replace trip waste face plate 15 EA ________ ___________
Vanity / Solid Wood, White - replace with size to match existing 20",24"or 30" including sink top in compliance with section 10805 of the specification
12 EA ________ ___________
0066 Bathroom Faucet / Single Lever Chrome - replace complete to include pop up drain stop 20 EA ________ ___________
0067 Closet Flange / Cast Iron, 4" - replace flange using leading joint includes anchoring flange in place 15 EA ________ ___________
0068 Toilet / 1.6 Gal Flush, White - replace two piece close couple china toilet 20 EA ________ ___________
A B C D E F
Toilet / Tank Parts - replace all parts including valve Flush Valve W/Adjust-a- Flush Flapper Tank-to- hardware and chrome tank lever
20 EA ________ ___________
0070 Toilet / Seat, White Plastic - replace round toilet seatwith cover to include new hardware 20 EA ________ ___________
0071 Sink / Kitchen, Stainless Steel, Self Rimming Double bowl size 33" x 22" x 6" depth replace including S.S brackets straines 8 EA ________ ___________
0072 Basket Strainer / Kitchen Sink, Stainless Steel - replace 8 EA ________ ___________
0073 Faucet / Kitchen, Single Lever, 8" Center Set With spray replace including new aerator 8 EA ________ ___________
0074 Utility Tub / Fiberglass, Size 25 1/4" x 22 3/4" including legs built in strainer and complete 4" laundry tud facet set 8 EA ________ ___________
0075 Faucet / Laundry, 4" Ledge Mount - replace complete set including all requried hardware 8 EA ________ ___________
0076 Hose Spray / Kitchen Sink 48"- replace hose, nozzle and sprayer 8 EA ________ ___________
0077 Hose Bib / Frost Free, Wall Mounted, 1/2" x 8" Long 15 EA ________ ___________
0078 INFORMATION CLIN
0078AA Replace Hot Water Heater 0078AB Water Heater / Gas, 40 Gallon - replace 10 EA ________ ___________
0078AC Water Heater / Electric, 40 Gallon - replace in compliance with section 15400 of the specification 10 EA ________ ___________
FLOORING
A B C D E F
0079 Patch concrete floor surfaces with portland cement max size 6" thick x 2 SF 240 EA ________ ___________
0080 Replace rubber stair tread 13" wide x 48" 5/16 (Length tyical) 400 EA ________ ___________
0081 Safety tread Replace aluminum safety tread 80 EA ________ ___________
0082 INFORMATION CLIN
0082AA Replace rubber or vinyl wall base 0082AB As above 4" high (all colors) 1,500 LF ________ ___________ 0082AC As above 6" high (all colors) 1,500 LF ________ ___________
0083 INFORMATION CLIN
0083AA Remove/dispose of existing VCT & Install new vinyl composition tile
0083AB Remove/dispose of existing VCT & Install new vinyl composition size 12" x 12" x 1/8 minimum 100 SF 3,750 SF ________ ___________
0083AC Install vinyl composition tile, size 12" x 12" minimum 100 SF over existing flooring size 9: x 9" 1/8 or 12" x 12" x 1/8 7,500 SF ________ ___________
0083AD Replace aluminum edge strips 60 LF ________ ___________ 0083AE Replace vinyl plastic edge strips 60 LF ________ ___________
Flooring / Replace Sheet Linoleum - installation shall be done in a fashion that will minimize floor seams all seams must conform to manufactures's specification in compliance with section 09950 of the specification
7,500 SF ________ ___________
FLOORING - CERAMIC / QUARRY
0085 Regrout existing cereamic or quarry tile match existing minimum 2
SF 3,000 EA ________ ___________
0086 INFORMATION CLIN
0086AA Replace tile 0086AB Replace quarry tile {Maximum size tile 6" x6" x 3/4 400 SF ________ ___________
A B C D E F 0086AC Replace quarry tile cove base 2" to 5" high 3/4 maximum thick 100 SF ________ ___________ 0086AD Replace quarry tile bull nose trim maximum 6" x 6" x 3/4 thick 100 LF ________ ___________ 0086AE Replace ceramic tile maximum size tile 12" x12" x 3/4 200 SF ________ ___________ 0086AF Replace ceramic tile cove base maximum 6" high 50 SF ________ ___________ 0086AG Replace ceramic tile bull nose trim maximum 6" x 12" 50 LF ________ ___________
CARPET
0087 INFORMATION CLIN
0087AA Remove, provide and install carpet to include all necessary materials for the installation of adhesives, molding and strips
0087AB Replace carpet with Carpet Standard I 1,300 SY ________ ___________ 0087AC Replace carpet with Carpet Standard II 1,300 SY ________ ___________ 0087AD Replace Carpet with Carpet Standard III (Carpet Tiles) 300 SY ________ ___________
CEILINGS
0088 INFORMATION CLIN
0088AA Replace suspended ceiling lay-in panels
0088AB Replace 24" x 24" mineral fiber acoustical lay-in-panels in existing suspension systems maximum 3/4 thick patterns vary 6,000 SF ________ ___________
0088AC Replace 24" x 48" mineral fiber acoustical lay-in-panels in existing suspension systems maximum 3/4 thick patterns vary 6,000 SF ________ ___________
0088AD
Replace 24" x 24" medium density insulated fiberglass ceiling panels in existing suspension systems maximum 3" thick R-13.6 patterns vary
6,000 SF ________ ___________
0088AE
Replace 24" x 48" medium density insulated fiberglass ceiling panels in existing suspension systems maximum 3" thick R-13.6 patterns vary
6,000 Sf ________ ___________
0089 Remove and reinstall existing insulation when new grid system is installed 6,000 SF ________ ___________
A B C D E F
Replace foil faced, fiber glass insulation over suspended ceiling or between framing members. Distancre between members to determine width of insulation 3 1/2" thur 6" full thick, 11" thur 15" wide R11 thur R19
4,000 SF ________ ___________
0091 INFORMATION CLIN
0091AA Replace Grid ceiling system
0091AB
Replace suspension system for exposed grid acoustical lay in panels T-bar for exposed grid, painted white, does not include tile 2' x 2' grid
10,000 SF ________ ___________
0091AC
Replace suspension system for exposed grid acoustical lay in panels T-bar for exposed grid, painted white, does not include tile 2' x 4' grid
10,000 SF ________ ___________
0092 Diffusers Replace aluminum air vent diffusers, 2' wide 45 EA ________ ___________
0093 INFORMATION CLIN
0093AA
Provide and install new overlay porcelain veneer panel system, new clips and sub-frame system over existing deteriorated delaminated, rusted and /or missing window face panel New porcelain panels shall be secured to the existing extruded aluminum window panel frame in strict compliance with manufacturer's specifications. See drawing for details
0093AB Porcelain veneer panel Provide new overlay porcelain veneer panel system 4' x 5' 10 EA ________ ___________
0093AC Porcelain veneer panel Provide new overlay porcelain veneer panel system 4' x 7' 30 EA ________ ___________
0093AD Porcelain veneer panel Provide new overlay porcelain veneer panel system 4' x 8' 30 EA ________ ___________
0094 Replace double glass window/door replace double strength glass in windows or doors maximum 9 SF 50 SF ________ ___________
0095 Glazing CompoundReplace deteriorated blazing compound on metal or wood window sash 200 LF ________ ___________
A B C D E F
ELECT RECEPTACLES/SWITCHES/BOX
0096 INFORMATION CLIN
0096AA Replace receptacle
0096AB
Receptacle / Wall, 15 Amp 125 Volt Duplex with ground replacement to include new plate. In compliance with section 16415 of the specification
25 EA ________ ___________
0096AC
Receptacle / 220 Volt for Range, Air Conditioner or Dryer replacement to include new plate in compliance with section 16415 of the specification
20 EA ________ ___________
0096AD Receptacle / Ground Fault Circuit Interrupter - replace to include new plate in compliance with section 16415 of the specification 30 EA ________ ___________
0097 INFORMATION CLIN
0097AA Replace switch
0097AB Switch / Single Pole - replace to include new plate. In compliance with section 16415 of the specification 30 EA ________ ___________
0097AC Switch / Three Way - replace to include new plate. In compliance with section 16415 of the specifications 10 EA ________ ___________
0097AD Switch / Dimmer - replace to include new plate. In compliance with section 16415 of the specification 20 EA ________ ___________
0098 Box, Electrical / Switch, Receptacle, Work or Junction. In compliance with section 16415 of the specification 30 EA ________ ___________
Plate / Wall, Plastic - Replace Single, Double, Triple, combo or jumbo for GFI, Duplex receptacle or switch in compliance with section 16415 of the specification
50 EA ________ ___________
INTERIOR LIGHTING
0100 INFORMATION CLIN
0100AA Replace surface Ceiling mounted fluorescent:
A B C D E F
0100AB Surface, Ceiling mounted fluorescent fixture size 2' x2' lensed, full flushed steel door Number lamps - 2 lamp type F32T8 Generic 50 EA ________ ___________
0100AC Surface, Ceiling mounted fluorescent fixture size 2' x 4' lensed, full flushed steel door Number lamps -4' lamp type F32T8 Generic 50 EA ________ ___________
0100AD Surface, Ceiling mounted fluorescent fixture size 1' x 4' wraparound lense, Number lamps - 2 lamp type F32T8 Generic 20 EA ________ ___________
0100AE Surface, Ceiling mounted fluorescent fixture size 2' x 4' wraparound lense, Number lamps - 4' lamp type F32T8 Generic 50 EA ________ ___________
0101 INFORMATION CLIN
0101AA Replace Troofer drop in lights 2' x 2'
0101AB Recessed Grid 2' x 2' Troffer, Static, Lensed, full flush steel door.
Number lamps -2 lamp type F32T8 60 EA ________ ___________
0101AC Recessed Grid 2' x 2' Troffer, Static, Parabolic, Number lamps -2 lamp type F32T8 60 EA ________ ___________
0101AD Recessed Grid 2' x 4' Troffer, Static, Lensed, Number lamps -4 lamp type F32T8 60 EA ________ ___________
0101AE Recessed Grid 2' x 4' Troffer, Static, Parabolic, Number lamps -4 lamp type F32T8 60 EA ________ ___________
0102 Open reflector, industrial (General Purpose) fixture, length 48" w/out lense, number lamps- 2 lamptypr F32T8 20 EA ________ ___________
0103 INFORMATION CLIN
0103AA Replace Specification Grade Highboy
0103AB
Specification Grade Highboy ,enclosed, pendant, integrally ballasted, industrial high intensity discharge fixture, cast aluminmum prismatic acylic reflector, lanp type - metal halide 250-
400 MH
15 EA ________ ___________
0103AC
Specification Grade Highboy ,enclosed, pendant, integrally ballasted, industrial high intensity discharge fixture, cast aluminmum prismatic acylic reflector, lamp type -High Pressure Sodium 250-400 MH
15 EA ________ ___________
A B C D E F
0104 Replace Exit Sign with energy efficient light emitting light emitting diode exit sign red color letering 40 EA ________ ___________
0105 INFORMATION CLIN
0105AA Replace emergency light
0105AB Replace emergency light 6 volt battery pack unit 2/two floodlights 25 EA ________ ___________
0105AC Replace emergency light 2 x2 w/ battery back up 25 EA ________ ___________
0106 Remove and reinstall existing light fixture in accordance with the specifications 25 EA ________ ___________
0107 INFORMATION CLIN
0107AA Replace light fixture wiring 0107AB 1/2" EMT Conduit 300 LF ________ ___________ 0107AC 3/4" EMT Conduit 300 LF ________ ___________ 0107AD Wiring MET Cable #12 700 LF ________ ___________ 0107AE Wiring MET Cable #10 700 LF ________ ___________
INTERIOR/EXTERIOR PREPARATION & PAINTING
0108 INFORMATION CLIN
0108AA Furnish all labor and material neceeary to prepare and paint interior / exterior
0108AB Surface preparation for extreme scraping, patching and cleaning of grease from surface to be painted 300,000 SF ________ ___________
0108AC
Presure Washing furnish pressure wash of exterior building surfaces to remove dirt, oil, residues and other coating using a pump capable of 3000 PSI. Bleach solution shall be sparyed on from top to bottom allowed to yield and rinse to remove all bleach residue
100,000 SF ________ ___________
0108AD Sandblast exterior masonry or metal surfaces prior to painting 20,000 SF ________ ___________
0108AE Repair Cracks 1/2 - inch wide or larger but not to exceed 2" wide 3,000 LF ________ ___________
A B C D E F
0108AF Repair cracks and holes in all interior surfaces prior to painting Holes 1/2" diameter or larger but not to exceed 2" in diameter 3,000 LF ________ ___________
0109 INFORMATION CLIN
0109AA Furnish all labor and material necessary to paint interior surfaces 300,000 SF ________ ___________
0109AB Paint 1coat previously painted interior surface in accordance with specification 200,000 SF ________ ___________
0109AC Each additional interior coat of paint in accordance with specification 200,000 SF ________ ___________
0109AD Seal floor in accordance with specification 10,000 SF ________ ___________
0109AE Apply 12-14 mil floor coating floor in accordance with specification 10,000 SF ________ ___________
0109AF Apply 3-6 mil floor coating floor in accordance with specification 10,000 SF ________ ___________
0109AG Apply non-skid surface in accordance with specification 1,000 SF ________ ___________
0110 INFORMATION CLIN
0110AA
Refinish natural or stained wood surfaces with polyurethane or varnish (gloss or semi gloss) as applicable includes sanding and staining as requried to match existing
0110AB Paint 1 coat in accordance with specification 200 SF
0110AC Each additional coat in accordance with specification 200 SF ________ ___________
0111 INFORMATION CLIN
0111AA Furnish all labor and material necessary to paint exterior surfaces ________ ___________
0111AB Paint 1coat previously painted exterior surface in accordance with specifications 150,000 SF
0111AC Each additional exterior coat of paint in accordance with spectifications 150,000 SF
0112 STUCCO repair and paint stucco with Astec #900 non-hazardous, nontoxi non flammable heat barrier ceramic elastomeric coating 30,000 SF ________ ___________
A B C D E F
0113 INFORMATION CLIN ________ ___________
0113AA Replace vinyl wall covering including wall preparation and or sizing compound
0113AB Replace wall covering light weight (12-15 oz/SY) fabric backed 2,000 SF
0113AC Replace wall covering medium weight (20-24 oz/SY) fabric backed 2,000 SF
0113AD Replace wall covering heavy weight (28 oz/SY) fabric backed 2,000 SF
LATRINES ________ ___________
0114 INFORMATION CLIN ________ ___________
0114AA
Replace Coated Metal Toilet Compartment- power coated bake enamel with finished thickness of doors and panels at 1" and pilasters at 1 1/4 " includes all hardware
0114AB Size 36" x 66" with swing out door Single compartment (stand alone) 10 EA ________ ___________
0114AC As above Two Compartments Adjacent 10 EA 0114AD As above Three Compartments Adjacent 10 EA 0114AE As above Four Compartments Adjacent 10 EA 0114AF Size 60" X 66" with swing out door Wheelchair accessible 10 EA ________ ___________
0115 INFORMATION CLIN ________ ___________
0115AA
Replace Solid plastic Toilet Compartment with 1" thick solid HDPE ( high density polyethylene) all panels and doos shall be fabricated of HDPE homogeneous in color and be 55" high includes all installation hardware
0115AB Size 36" x 66" with swing out door 10 EA ________ ___________ 0115AC As above Two Compartments adjacent 10 EA 0115AD As above Three Compartments adjacent 10 EA 0115AE As above Four Compartments adjacent 10 EA
A B C D E F
0115AF Size 60" X 66" with swing out door wheelchair accessible 10 EA ________ ___________
0116 INFORMATION CLIN ________ ___________
0116AA Replace Commode complete installation with hardware ________ ___________
0116AB
Replace commode, siphon jet, elonggated bowl complete with flush valve with back-flow preventer and open or closed front seat without cover and floor flange
10 EA
0116AC
Replace ADA compliant commode, siphon jet, elonggated bowl complete with flush valve with back-flow preventer and open or closed front seat without cover and floor flange
10 EA ________ ___________
0116AD
Replace commode, siphon jet, regular bowl complete with flush valve with back-flow preventer and open or closed front seat without cover and floor flange
10 EA
0116AE
Replace ADA compliant commode, siphon jet, regular bowl complete with flush valve with back-flow preventer and open or closed front seat without cover and floor flange
10 EA ________ ___________
0117 Reset commode and replace wax seal on commode 10 EA ________ ___________
0118 Rebuild flushometer using proper flushometer repair kit (commode & urinal) 10 EA
0119 Replace flushometer handle 10 EA ________ ___________
0120 INFORMATION CLIN
0120AA Replace toilet seat ________ ___________ 0120AB Replace commode seat for regular or elongated bowl, closed or opened front less cover 10 EA 0120AC Replace commode seat with cover for regular bowl with cover 10 EA ________ ___________
A B C D E F 0121 Replace urinal wall hung type with flush valve and trap 10 EA ________ ___________
0122 Replace P-trap to urinal 10 EA ________ ___________
0123 Replace tail piece to urinal 10 EA ________ ___________
0124 Rehang urinal 10 EA ________ ___________
Replace single compartment service or laundry sink max size 25" length, 24" width and 16" depth concrete or fiberglass, complete with faucewt set, rubber stopper, chair, waste connection and stand 18" high
10 EA
0126 Replace lavatory (maximum size 24" x 20") complete with 4" combination faucet set to match existing with riser pipe and trap 10 EA ________ ___________
0127 INFORMATION CLIN
0127AA Replace Lavatory Faucet Set ________ ___________
0127AB Replace lavatory 4" center-set faucet set to match existing with drain fitting with pop up drain, and riser piping 10 EA
0127AC Replace lavatory 4" center-set faucet set to match existing with drain fitting with chair and stopper, and riser piping 10 EA ________ ___________
0128 Faucet / Repair - to include deck faucet, center set, tud & shower diverter and replacement of all washers and seats 10 EA ________ ___________
0129 Rehang existing lavatory 10 EA ________ ___________
Replace swing type landry or service sick faucet set to match existing 10 EA ________ ___________
A B C D E F 0131 Replace tail piece to lavatory 10 EA
0132 Replace P-trap on lavatory or laundry sink tomatch existing 10 EA ________ ___________
LATRINES ACCESSORIES ________ ___________
0133 Replace shower faucet handle to match existing 10 EA ________ ___________
0134 Replace adjustable shower head {Vandal Resistant) 1/2 '' FIP female connection 10 EA ________ ___________
0135 Replace toilet paper holder to match existing chrome plated brass 10 EA ________ ___________
0136 Replace metal soap dish {to match existing chrome plated finish 10 EA ________ ___________
0137 Replace latrine mirror stainless steel frame and theft-proof hanging clips maximum size 36" x 24" 15 EA ________ ___________
0138 Replace 3" hadicap stainless steel grab bar to include fasteners 12 EA ________ ___________
0139 Replace cast iron floor drain to match existing 4' outlet maximum 15 EA
0140 Replace perforated or slotted, brass chrome plated cover for existing floor drain 11" diameter maximum 10 EA ________ ___________
PLUMBING VALVES & PIPE (METAL) ________ ___________
0141 Valve / Stop, Chrome, Angle or Straight - replace with size 1/2 " sweat x 3/8 "OD compression or 3/8 I.P.S x 3/8 compression 15 EA ________ ___________
A B C D E F 0142 Replace outside non-freeze faucet 12 EA
0143 Replace hose bib brass, with steel handle, either straight or angle body Maximum size 3/4 " 10 LF ________ ___________
0144 INFORMATION CLIN ________ ___________
0144AA Replace cooper water line ________ ___________ 0144AB Replace 1/2" copper water line 200 LF ________ ___________ 0144AC Replace 3/4" copper water line 200 LF 0144AD Replace 1" copper water line 300 LF 0144AE Replace 1 1/4" -1 1/2" copper water line 50 LF 0144AF Replace 2" - 2 1/2" copper water line 20 LF ________ ___________
0145 INFORMATION CLIN ________ ___________
0145AA Replace pipe hanger 0145AB Replace pipe hanger 1/2" thur 1" 35 EA
0145AC Replace pipe hanger1 1/4" thur 1 1/2" 25 EA
0145AD Replace pipe hanger 1 3/4" thur 2 1/2" 15 EA ________ ___________
0146 INFORMATION CLIN ________ ___________
0146AA Replace pipe covering insulation, fiberglass to match existing maximum 10 LF ________ ___________
0146AB Replace pipe covering insulation, 1/2" thur 1" OD pipe 250 EA ________ ___________ 0146AC Replace pipe covering insulation, 2" thur 2 1/2 "OD pipe 250 EA 0146AD Replace pipe covering insulation, 1" thur 1 1/2 "OD pipe 250 EA 0146AE Replace pipe covering insulation, 3" thur 3 1/2 "OD pipe 250 EA 0146AF Replace pipe covering insulation, 4" OD pipe 250 EA ________ ___________
0147 INFORMATION CLIN ________ ___________
0147AA Replace gate valve ________ ___________ 0147AB Replace bronze gate valve (1/2") 10 EA ________ ___________ 0147AC Replace bronze gate valve (3/4") 10 EA ________ ___________ 0147AD Replace bronze gate valve (1") 15 EA
A B C D E F 0147AE Replace bronze gate valve (1 1/2") 15 EA 0147AF Replace bronze gate valve (2") 15 EA 0147AG Replace bronze gate valve (2 1/2") 15 EA
PVC PIPE/FITTINGS ________ ___________
0148 INFORMATION CLIN
0148AA Replace PVC pipe
0148AB Pipe / PVC, 1 1/2" Dia. Sch. 40 - replace, including any necessary hangers 100 LF
0148AC Pipe / PVC, 2" Dia. Sch. 40 - replace, including any necessary hangers 100 LF ________ ___________
0149 INFORMATION CLIN
0149AA Replace PVC fitting
0149AB Fitting / PVC, 1 1/2" Dia. Sch 40 - replace one of the following coupling, adapter (male or female) 90 deg or 45deg elbow 30 EA
0149AC Fitting / PVC, 2" Dia. Sch 40 - replace one of the following coupling, adapter (male or female) 90 deg or 45deg elbow 30 EA ________ ___________
0150 INFORMATION CLIN ________ ___________
0150AA Replace PVC coupling 0150AB Coupling / Fernco, 1 1/2" - replace 20 EA ________ ___________ 0150AC Coupling / Fernco, 2" - replace 20 EA
0150AD Coupling / Fernco, 4" - replace 20 EA ________ ___________
Supply Tube / Plastic - replace 3/8" OD or 1/2" OD plastic supply tube on lavatory, kitchen sink or toilet. In compliance with section 15400 of the specification
20 LF ________ ___________
A B C D E F
0152 Trap / PVC "P", 1 1/4" or 1 1/2" - replace. In compliance with section 15400 of the spectification 20 EA ________ ___________
Tailpiece / PVC, 1 1/2" x 8" - replace flanged tailpiece, straight pr wwith dishwasher connection in compliance with section 15400 of the spectification
20 EA
0154 Continuous Waste / PVC, 1 1/2" x 24" - replace with end or center outlet in compliance with section 15400 of the specification 20 EA
ROLL-UP AND SECTIONAL OVERHEAD DOORS ________ ___________
0155 INFORMATION CLIN
0155AA Replace steel overhead roll-up/Sectional doors 11' - thur 16' - 2"
0155AB As above {Insulated} 9' 8" through 22' - 2" wide 400 SF
0155AC As above {Un-insulated} 9' - 8" through 22' - 2" wide 400 SF ________ ___________
0156 INFORMATION CLIN
0156AA Replace aluminum overhead roll-up doors 11' - 8" thur 16' - 2" high
0156AB As above {Insulated} 9'- 8" through 22'-2" wide 300 SF
0156AC As above {Un-insulated} 9' - 8" through 22'- 2" wide 300 SF ________ ___________
0157 INFORMATION CLIN ________ ___________
0157AA Repairs/replacements for steel and/or aluminmumsectional and roll-up doors. ________ ___________
0157AB Replace door springs. 10 EA ________ ___________ 0157AC Replace cables 10 EA ________ ___________ 0157AD Replace electric door operators {chain or belt) 10 EA ________ ___________ 0157AE Replace electric door operator safety bottom edge 10 EA ________ ___________
A B C D E F 0157AF Repair/replace electric push button control 10 EA ________ ___________ 0157AG Repair/replace tracks 10 EA ________ ___________ 0157AH Replace hinges and rollers. 10 EA ________ ___________ 0157AJ Replace neoprene internal hood baffles 10 LF ________ ___________ 0157AK Replace neoprene astragal 10 EA ________ ___________ 0157AL Replace vision panels 10 EA 0157AM Replace weather stripping 300 LF 0157AN Replace motor on operator 10 EA 0157AP Replace complete operator 10 EA
EXTERIOR SIDING ________ ___________
0158 INFORMATION CLIN ________ ___________
0158AA
Replace and/or cover existing surfaces, complete with vinyl siding and polystyrene insulating backer and all necessary trim, molding and fasteners for a complete job. Choice of color to be selected by QAR per delivery order
0158AB Siding 8" w/backer 1,000 SF ________ ___________ 0158AC Siding dbl 4" w/backer 1,500 SF ________ ___________ 0158AD Siding vertical 10" w/backer 200 SF ________ ___________ 0158AE Ouside corner post 200 LF ________ ___________ 0158AF Inside corner post 40 LF ________ ___________ 0158AG J panel 800 LF ________ ___________ 0158AH Starter strip (horizontal) 200 LF ________ ___________ 0158AJ Drip cap 200 LF ________ ___________ 0158AK Soffit panel 10" 400 SF ________ ___________ 0158AL Soffit panel (perforated) 200 SF ________ ___________ 0158AM Starter strip (vertical) 200 LF 0158AN Fascia panel 12" 400 LF
0158AP Furring Strip 1" X 3" 200 LF ________ ___________
0158AQ Install 3/4" insulation Urethane rigid insulation 200 SF ________ ___________
A B C D E F
SIDING OTHER THAN VINYL
0158AR Aluminum Siding Panel .032" thick min corrugated or ribbed, color as specified 4000 SF
0158AS EFIS, 2" thru 4" thick with reinforcement, finish to match existing texture and painted to match existing color 2000 SF
0158AT Fascia Aluminum .032" thick min, 12" thru 20" color as specified 5000 LF
GUTTERS AND DOWNSPOUTS ________ ___________
0159 INFORMATION CLIN ________ ___________
0159AA Repair/Replace Guttters, Downspouts ________ ___________
0159AB
Aluminum Gutters / Leaders Downspouts repair / rehang including all haedware & sealant as directed by QAR. Size 3" thur 5" in compliance with section 07600 of the specification
2000 LF ________ ___________
0159AC
Aluminum Gutters / Leaders Downspouts replace with minimum .027 thickness including all hardware & sealant as directed by QAR. Size 3" thur 5" in compliance with section 07600 of the specification
2000 LF ________ ___________
0159AD Aluminum Gutters / Leaders Downspouts clean and flush size 3" thur5" in compliance with section 07600 of the specification 2000 LF ________ ___________
0159AE Gutter Hardware Replace - brackets, hangers and joints 2000 LF ________ ___________
0159AF
Aluminum Gutters / Leaders Downspouts repair / rehang including all haedware & sealant as directed by QAR. Size 6" thur 8" in compliance with section 07600 of the specification
500 LF ________ ___________
A B C D E F
01595AG
Aluminum Gutters, Commercial Box or "K" replace with minimum .032 thickness including all hardware & sealant as directed by QAR. Size 6" thru 8" in compliance with section 07600
8,000 LF ________ ___________
0159AH Downspout, Commercial Rectangular .025" thick min Aluminum, 3" x 4" brown, to include all elbows, connectors, and hardware 5,000 LF ________ ___________
0159AJ Aluminum Gutters / Leaders Downspouts repair / rehang including all hardware & sealant as directed by QAR Size 10" thru 12" in 200 LF
0159AK Aluminum Gutters / Leaders Downspouts replace with minimum 032 thickness including all hardware & sealant as directed by 200 LF
01595AL Aluminum Gutters / Leaders Downspouts clean and flush size 10" thru 12" in compliance with section 07600 of the specification 200 LF
0159AM Gutter Hardware, Commercial Replace - brackets, hangers and joints 2,000 LF ________ ___________
MASONARY - INTERIOR ________ ___________
0160 Plaster - Replace / Repair wall or ceiling on metal lath or masonry surface Repairs include replacement of lath priming and painting 300 SF ________ ___________
0161 Repair interior concrete or masonry surfaces (cracks,spalls, holes) larger than 2- inches 300 LF ________ ___________
0162 Replace deteriorated interior masonry block to match existing 100 EA
0163 Replace interior brick to match existing to include wall ties as required 200 EA
MASONRY - EXTERIOR ________ ___________
0164 INFORMATION CLIN ________ ___________
0164AA Fill cracks and fill holes in exterior surfaces with materials compatable with existing surfaces ________ ___________
0164AB Cracks 1/2-inch wide or larger but not to exceed 2- inches in diameter 750 LF ________ ___________
A B C D E F
0164AC Holes 1/2 inch wide or larger but not to exceed 2 " in diameter 800 SF ________ ___________
0164AD Surface (cracks, holes or spalls) larger than 2" minimum 6' SF 750 SF
0164AE Apply masonry filler and sealer or apply metal primer to sandblasted surfaces as applicable 12,000 SF
0164AF Remove deteriorated masonry from brick to block surfaces and repoint to comform with existing surfaces 100 EA
0164AG
Replace/apply caulking between similaror dissimilar interior or exterior construction material to include backup material as required
100 LF
ROOFING ________ ___________
0165 INFORMATION CLIN
0165AA Repair/Replace Asphalt Roofing system 0165AB Replace asphalt shingles to match existing 25 sf minimum 1200 SF 0165AC ROOF CAP repair / replace metal roof cap 600 LF ________ ___________
0166 ROOFING OTHER THAN ASPHALT SHINGLE ________ ___________
0166AA Replace mineral surfaced rolled roofing to match existing ________ ___________
0166AB 90 PD Min Surface 200 SF ________ ___________
0166AC 90 PD Sol Edge 200 SF ________ ___________
0166AD Steel Roofing corrugated or ribbed panel, 24 ga min painted or zinc coatied as specified 10,000 SF
0166AE EPDM 45 mil, fully adhered or loose laid with ballast as directed 8,000 SF 0166AF Built-Up Asphalt fully mopped 15 lb felt, number of plies, and surface finish to match existing roof (includes ballast if required) 8,000 SF
0166AG Modified Bituminous Membrane fully mopped, 15 lb base with 150 mil cap, sheet surface to match exisiting roof 8,000 SF ________ ___________
CHAIN LINK FENCE
0167 Remove and dispose of existing fence 6'- 8' high 2,000 LF ________ ___________
A B C D E F
0168 INFORMATION CLIN ________ ___________
0168AA Remove and install new chain link fence post ________ ___________ 0168AB Complete as above, end post 3" 50 EA 0168AC Complete as above, corner post 4" 50 EA 0168AD Comple as above, Line post single 2 1/2 in 50 EA
0168AE Complete as above, Top rail 1 5/8 in 50 LF ________ ___________
0169 INFORMATION CLIN
0169AA Remove and install new chain link fence 9 guage
0169AB Replace 6' high 9 ga. Wire, galvanized chain link fence, single extension arm w/3 strands barb wire 1000 LF
0169AC Replace 8' high 9 ga. Wire, galvanized chain link fence, single extension arm w/3 strands barb wire 1000 LF ________ ___________
0170 INFORMATION CLIN ________ ___________
0170AA Remove and Install new chain link fence gate ________ ___________
0170AB Remove 12' double gate to include disposal 6' - 8' high 12 EA 0170AC Remove 24' double gate to include disposal 6' - 8' high 12 EA
0170AD Replace 12' double gate with 3 strains barbed wire, single extension arm 6" - 8" high 12 EA
0170AE Replace 24' double gate with 3 strains barbed wire, single extension arm 6'' - 8" high 12 EA ________ ___________
0171 INFORMATION CLIN
0171AA Replace concrete and Bollards 0171AB Complete as above, replace concrete 50 CY 0171AC Replace Bollards, 6" 50 EA
MISC METAL WORK ________ ___________
A B C D E F
0172 INFORMATION CLIN ________ ___________
0172AA Repair/replace radiator hardware ________ ___________
0172AB Replace radiator, convector or register cover to match existing Maximum 5 LF 50 LF
0172AC Rehang existing radiator or convector to include fasteners and brackets Maximum 5 LF 40 LF
0172AD Replace aluminum air vent diffusers, 2' wide 20 EA 0172AE Repair/replace double wall metal chimneys 100 LF
MISCELLANEOUS LABOR ________ ___________
0173 INFORMATION CLIN ________ ___________
0173AA Labor / Skilled - perform minor repairs as directed by QAR to include carpentry, electrical, plumding and metal trades ________ ___________
0173AB Perform miscellaneous minor carpentry work 240 HR ________ ___________ 0173AC Perform miscellaneous minor electrical work 240 HR ________ ___________
0173AD Perform miscellaneous minor plumbing work 240 HR ________ ___________
0173AE Perform miscellaneous labor work 240 HR 0173AF Perform miscellaneous sheet metal work 240 HR 0173AG Perform miscellaneous welding work 240 HR
0173AH
Move Furniture and Partition - Disassemble, Move, and Re-assemble to facilitate replacement of flooring. Not to be used for lifting in place, movement of chairs, or furniture items not requiring assembly.
2000 SF
ASBESTOS ABATEMENT ________ ___________
0174 INFORMATION CLIN ________ ___________
A B C D E F
0174AA Complete Removal, all tests , monitoring, setups, notifications, material, labor and disposal of asbestos floor tile and insulation ________ ___________
0174AB Asbestos floor tile and mastic Removal 10,000 SF ________ ___________
0174AC Asbestos floor tile, mastic and carpet removal 10,000 SF ________ ___________
0174AD Remove Asbestos pipe covering insulation, replace with equivelant fiberglass insulation up to 4" pipe 300 LF ________ ___________
0174AE Remove Asbestos pipe covering insulation, replace with equivelant fiberglass insulation 4" thur 8" pipe 100 LF
0174AF Remove Asbestos pipe covering insulation, replace with equivelant fiberglass insulation 10" thur 12" pipe 100 LF
0174AG Remove Asbestos boiler covering insulation, replace with equivelant insulation 300 SF
0174AH Remove Asbestos Duct or AHU covering insulation, replace with equivelant insulation 100 SF
A B C D E F
MAINTENANCE AND REPAIR OF BUILDINGS
FACILITIES AND STUCTURES AT JOINT BASE MCGUIRE-DIX-LAKEHURST (JB MDL)
PERFORMANCE PERIOD OPTION YEAR 1
The Contractor shall furnish all plant, labor, equipment, tools, supplies and materials and perform all work necessary to perform maintenance and repair of buildings, facilities and stuctures at JB MDL, NJ in accordance with attached specifications period of 20 Sep 16 TO 19 Sep 17
1002 INFORMATION CLIN QTY UNIT COST TOTAL
1002AA Replace and paint wood interior, flush solid door 2'-8" x 6'-8" thur 7'-0"
1002AB Complete as above 20 EA ________ ___________ 1002AC Complete as above, with vision lights. Max 12SF of glass area 15 EA ________ ___________
1002AD Complete as above with louvers to match existing or measure 10" or less than width of door and have a max height of 48" 15 EA ________ ___________
1002AE Complete as above B Label fire (90 min) rated door 15 EA…