Drawings_NKAK_10-1100_Civil_Works_IDIQ.pdf

PDF 24 MB Posted

Attached to
Base Civil Works IDIQ
Solicitation number
FA4460-14-R-0004
Issued by

About this file

Drawings NKAK 10-1100 Civil Works IDIQ

View the file

Other files

Show all 16

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Low Tilt

18" Hex.

29.0"

3.5" X 4.5" X 5"H

HAND HOLE

(2 PER POLE)

0°

90°270°

180°

Handhole Location

2.0"

Ø9.0" Bolt Circle Ø7.0"

Opening

12'

S4J 18.0" Hex.

SEE

LIGHT POLE

FOUNDATION

DETAIL

SHEET E1

3' -6

Ø1'-7"

HINGED DOOR HOUSING

ELECTRONIC MODULE

WITH TWISTLOCK

RECEPTACLE

(OPTIONAL)

LUMINAIRE

HOUSING

OPTICAL

ASSEMBLY

CAST ALUMINUM

FINIAL

COVER

LATCH

SLIPFITTER FOR

NOMINAL 3" DIA.

TENON SET SCREWS

PHOTOCELL

WINDOW

OPPOSITE DOOR

OPENING

WASHINGTON UTILITY FULL CUT OFF LED SPECIFICATION

GENERAL DESCRIPTION

The Utility Washington Full Cutoff LED is designed for ease of maintenance with the plug-in electrical module common to each of the luminaires in Holophane's Utility Luminaire Series. A precision optical system maximizes post spacings while maintaining uniform illumination.

OPTICAL SYSTEM

The optical system consists of a precisely engineered LED circuit board located in the top cover. A gasket between the cover and ring along with a flat glass plate and gasket beneath the reflector create a sealed optical compartment that meets an IP rating. Optics designed to provide an I.E.S. Asymmetric or Symmetric full cutoff distribution are available.

LUMINAIRE HOUSING

The luminaire housing, cast of aluminum, anchors the optical system and provides an enclosure for the plug in electrical module. The electrical enclosure conforms to an IP55 rating. For use with units with an E.E.I.-N.E.M.A. twist lock photocell receptacle, the housing contains a glass "window" to allow light to reach the cell. The nickel plated lamp grip socket and the three station incoming line terminal block are pre-wired to a five conductor receptacle for ease in connecting the electrical module. A slipfitter will accept a 3" high by 2 7/8" to 3 1/8" O.D. pole tenon.

LUMINAIRE HOUSING DOOR

Cast of aluminum, the housing door is hinged and latched to the housing. The door forms the mount for the electrical module, and allows easy access during maintenance.

ELECTRICAL MODULE

The electrical components are mounted to an aluminum plate that is removable with standard tools. A matching five plug connector connects the electrical components to the surge protector for quick replacement. For Photoelectric operation, the electrical module is provided with an E.E.I.-N.E.M.A. twist lock Photocell receptacle

TOP COVER

The top cover, cast of aluminum, is attached to the top ring of the luminaire housing by a stainless steel hinge pin. The cover is latched by an overcenter, positive action, stainless steel latch which allows tool-less entry to the lamp chamber for relamping.

DRIVER

Voltage sensing 120-277V or 347-480V, 50/60 Hz electronic drivers are >90% efficient. Potted for increased thermal management.

Removable through hinged door housing. Available with 0-10V dimming control signal input. Refer to Driver Data Sheet for specific operating characteristics.

FINISH

The luminaire is finished with polyester powder paint applied to ensure maximum durability.

UL

The luminaire is UL listed as suitable for wet locations at a maximum of 40 degrees C ambient temperature.

PRINCETON ALUMINUM POLE SPECIFICATION

DESCRIPTION

The lighting post shall be all aluminum, one-piece construction, with a classically curved base design.

MATERIALS

The base and fluted tapered cast shaft shall be heavy wall, cast aluminum produced from certified ASTM 356.1 ingot per ASTM B-179-95a or ASTM B26-95. The straight shafts shall be extruded from aluminum, ASTM 6061 alloy, heat treated to a T6 temper. The tapered shaft shall be extruded from aluminum, ASTM 6063 alloy, spun to a tapered shape, then heat treated to a T6 temper. All hardware shall be tamper resistant stainless steel. Anchor bolts to be completely hot dip galvanized.

CONSTRUCTION

The shaft shall be double welded to the base casting and shipped as one piece for maximum structural integrity. The shaft shall be welded inside the base casting at the top of the access door, and externally where the shaft exits the base. All welding shall be per ANSI/AWS

DIMENSIONS

The post shall be 12'- 00" in height with a 18" hexagonal base. The shaft diameter shall be 4". At the top of the post, an integral tenon with a transitional donut shall be provided for luminairemounting.

INSTALLATION

The post shall be provided with four, hot dip galvanized L-type anchor bolts. A door shall be provided in the base for anchorage and wiring access. A grounding screw shall be provided inside the base opposite the door.

STEEL POST SCHEDULE

USE AND SECTION

MINIMUM OUTSIDE DIMENSIONS (NOMINAL)

FABRIC WIDTH 72" OR LESS

FABRIC WIDTH 84" TO 96" FABRIC WIDTH 108" AND OVER

NO SCALE

NO SCALE

NO SCALE

X

X

02_FE5FEN1.DWG

X

X

X

FE5 CHAIN-LINK SECURITY

FENCE DETAILS

A

B

C

D

5 4

Submitted by:

Reviewed by:

Checked by:

Designed by:

Chief:

Drawn by:

number:

reference

Sheet

OMAHA, NEBRASKA

CORPS OF ENGINEERS

U.S. ARMY ENGINEER DISTRICT

Spec. No.:

DACA 45

DACA 45

Contract No.:

Section

Design File:

Plot Scale Ratio:

BASE NAME

Drawing Code:

STD 872-90-02

03/17/04

Date:

BASE LOCATION

A

Symbol

Approved

$$ - THINK VALUE ENGINEERING - $$

Descriptions

Revisions

Date

B

C

D

NOTES:

FENCE LEGEND:

FE5 CHAIN-LINK SECURITY FENCE DETAIL

FASTENING DETAILS

BRACE RAIL CLAMP DETAILS

ROUND POST

H-BEAM

TENSION BAND DETAIL

END OR GATE POST DETAIL

TOP OR BRACE RAIL ATTACHMENT

ROUND POST

H-BEAM

LINE POST ATTACHMENTS

GROUNDING DETAIL

BRACE PANEL DETAIL

TRUSS ROD AND BAND

STANDARD DETAILS FOR CHAIN-LINK

SECURITY FENCES, FARM STYLE FENCES

AND A DOUBLE CABLE BARRIER

NO SCALE

NO SCALE

1 T1
2-6 C1-C5
7-8 E1-E2_
9-10 G1-G2
11 G3
12 G4
13 G5
14 G6
15-29 CG-1 - WR-2
30-38 FE5 - FM2

File details come from the government source that posted it. Updated .