STATEMENT OF WORK
AGGN 131034
REPAIR GYM FLOOR
22 APRIL 2013
1. PURPOSE: Repair maple wood flooring that has water damage at the base gym.
2. SCOPE: Contractor shall provide all plant, labor, materials, travel, equipment and supervision necessary to perform all work required to repair the gym floor at Altus AFB, Oklahoma as stated herein and in the contract technical provisions.
3. DESCRIPTION OF WORK;
A. The contractor is required to repair and replace water damage area that is approximately 1100
sq. feet.
B. Floor will be Maple, grade 2 or better, 25/32 and 2 ¼ wide. The Maple will be NOFMA approved to match existing.
C. Repair edge where the floor was replaced.
D. Sand gym floor with coarse, medium, fine and extra fine sandpaper.
E. Apply one coat of gym floor sealer, will be oil base sealer but must be MFMA (Maple Flooring Manufactures Association) Approved.
F. Contractor will apply two coats finisher, may be oil base and MFMA approved G. Repaint game lines where the floor was repaired.
H. Contractor must be a participant in the MFMA accreditation program
4. SUBMITTALS: Contractor is responsible to provide a schedule and MSDS for any or all chemicals being used in the process.
5. PRE-WORK REQUIREMENT: New maple wood will be on site and acclimated two weeks prior to work starting.
6. ANTI-TERRORISM CLAUSE:
Altus Air Force Base has an antiterrorism program that is responsible for helping secure and protect the base and its personnel from terrorist attacks. As a contractor working on Altus Air Force Base, you and your sub-contractors are required to obey all orders from Security Forces, and adhere to all security measures implemented as a result of Force Protection Condition changes (security posture changes). Additionally, you and your sub-contractors are expected to report to base security forces any suspicious activities, packages, or items you see while conducting work on Altus Air Force Base. Suspicious activities could include personnel conducting surveillance of the installation, unauthorized personnel requesting access to the installation, or somebody asking a lot of questions about the base. In an effort to help familiarize you, your employees, and sub-contractors about antiterrorism, Altus Air Force Base has an antiterrorism binder with all of the pertinent information for awareness training available for review at the Pass and Registration Office located at the south gate (building #428) of Altus Air Force Base, Oklahoma.
FA4419-13-R-0107 Repair Gym Floor SOW Attachment #1
7. INFORMATION PROTECTION SECURITY CLAUSE:
Pass and Identification Items. The contractor shall ensure the following pass and identification items required for contract performance are obtained for employees and non-government owned vehicles requiring access to Altus AFB to perform contract requirements:
A. The contractor is responsible for providing information to assist in completing background checks for those employees requiring access to Altus AFB. This information shall consist of, but not limited to, the following: full name to include first, middle, and last, social security number, date of birth, address, driver’s license number and state of issue, number of years resident of the State of Oklahoma and Jackson County. This information will be protected under the procedures listed under the Privacy Act of 1974. A background check must be completed prior to unescorted access. Those contractor employees whose background checks reveal adverse criminal history may be denied access to Altus AFB.
B. The contractor is responsible for tracking and retrieving badges from employees upon separation, termination and/or completion of business on Altus AFB, Oklahoma. Badges from employees no longer working on the contract must be turned in to the Contracting office within 30 days of leaving.
C. Businesses may lose base pass privileges if they fail to control use of the badges or do not return them upon completion of use. Excessive abuse may result in termination or a decision not to exercise option periods for this contract. Employees who abuse their badge privileges by attempting base access beyond the dates, times, locations or specified work and other limitations may be subject to revocation of base access.
8. GENERAL REQUIREMENTS:
All Federal Specification designations shall be used as a guide as to the type of material required. The Contractor shall not deviate from using the Government approved products without the written authorization of the Contracting Officer. All debris generated during this project will be cleaned up and disposed of off Altus AFB by the contractor at the contractor’s expense. Contractor work times will be 7:30 AM to 4:30 PM Monday through Friday, excluding federal holiday.
END SOW