Parts List.xlsx
XLSX spreadsheet 25 KB Posted
- Attached to
- Hyperbaric Stretchers Federal contract opportunity
- Solicitation number
- FA441725Q0093
About this file
The file is a Parts List for a Hyperbaric Stretcher Solicitation (FA441725Q0093) issued by the Department of the Air Force Special Operations Command. The comprehensive parts list details a Hyperbaric Stretcher (CLIN 0001) with multiple components from SOS Group, including an inflatable tube assembly, control box, regulators, medical locks, carrying straps, and ancillary equipment. The solicitation is restricted to small businesses and requires Brand Name or Equal items, with all quotes needing to include delivery to Hurlburt Field, FL.
Key solicitation details include a response deadline of 19 March 2025 at 1:00 PM CST, with quotes valid through 30 September 2025. The procurement uses lowest price technically acceptable evaluation criteria under NAICS code 334510 with a size standard of 1,250 employees. The award will be made on an All or None basis, requiring offerors to quote on all items, and mandating active SAM registration. Delivery is FOB Destination, and while funds are not currently available, the government reserves the right to award the contract when funding becomes accessible.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Combo - FA441725Q0093 Amendment 1.pdf | ||
| Combo - FA441725Q0093.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Hyperbaric Stretcher
| CLIN 0001 Hyperbaric Stretcher Parts List | |||||
| Item | Manufacturer | Part # | Description | QTY | Brand Name |
| 1 | SOS Group | SSHP01- 0000Y | Hyperlite 1 Built to Military Specification including: - |
Inflatable Tube Assembly HP01-03-01 x 1, Cover Assembly HP01-03-05 x 1 Window Assembly HP01-04-01 x 2 containing Penetrator Plate Assembly & Medical Lock.
BiBS Assembly HP01-05-00 x 1, Umbilical Hose Assembly HP01-07-00 x 1, Hose End Protector HP01-28-00 x 2, Exhaled Breathing Gas Hose HP01-07-04 x 1, Remote Air Inlet Hose HP01-07-06 x 1, Control Box HP01-06-00 x 1, Regulator Pocket HP01-26-00 x 4, Air Regulator with DIN Fitting HP01-12-02 x 2, Oxygen Regulator with CGA 540 Fitting HP01-13-02 x 2, Hyperlite 1 1640 Split Chamber Case Assembly HP01-15-00 x 2, Medical Lock Pocket (Small) HP01-27-00 x 2, Lifting Handle Straps HP01-05-07 x 2, Sprung Hoop Assembly Mod1 HP01-38-00 x 3, Drag Mattress HP01-17-00 x 1, Drag Mattress Pull Strap Assembly HP01-18-00 x 1, Slip Mattress HP01-19-00 x 1, Central Carrying Strap HP01-22-00 x 1, Carrying Strap with Wedge Assembly HP01-23-00 x 2, Pull Handle for window HP01-24-00 x 2, Control Box Strap HP01-25-00 x 4, Pen Plate Protector HP01-29-00 x 1, Window Protection Cover HP01-30-00 x 2, Foam Spacer Ring (Thin) HP01-32-00 x 1, Foam Spacer Ring (Thick) HP01-31-00 x 1, Horizontal Lifting Sling HP01-21-00 x 1, External Analog Back-Up Pressure Gauge (FSW/MWS) HP01-07-05 x 1, Hyperlite 1 Ancillary Equipment Case HP01-34-00 x 1, LCD Dual Timer x 1, Cylinder Adapters Set A x 1, Repair Patch Set HP01-33-00 x 1, RS PRO Phillips Stubby Screwdriver PH1 Tip SDR001 x 1, 2-Way Duplex Intercom System HP01-11-00 x 1, Packing Instructions Hyperlite 1 x 1, Folding Tube Instructions Hyperlite 1 x 1, Chamber Logbook x 1, Hyperlite 1 Operations Manual x 1, Mil Spec Documentation Package HP01-02-01mdoc x 1, O-Ring Spares Kit x 1,
| Christ-O-Lube x 1 | 1 | Brand Name Or Equal | ||||
| 2 | SOS Group | SAT006 | SOS Atmosphere monitoring system case with PSU & Plug-In Sensor Pack with light - Imperial measurements. To include the following parameters - Pressure, Temperature, Humidity, O2% and CO2 %SEV | 1 | Brand Name Or Equal | |
| 3 | SOS Group | HYP1TAC01 | Hyperlite 1 Treatment Kit. | 1 | Brand Name Or Equal | |
| 4 | SOS Group | HYP1MKT001 | Hyperlite 1 Maintenance Kit. | 1 | Brand Name Or Equal | |
| 5 | SOS Group | HP01-06-00 | Hyperlite 1 Control Box | 1 | Brand Name Or Equal | |
| 6 | SOS Group | HP01-12-02 | Hyperlite 1 Air Regulator Assembly with DIN 232 Fitting | 2 | Brand Name Or Equal | |
| 7 | SOS Group | HP01-13-02 | Hyperlite 1 Oxygen Regulator Assembly with CGA 540 Fitting | 2 | Brand Name Or Equal | |
| 8 | SOS Group | HP01-26-00 | Regulator Pocket Assembly | 4 | Brand Name Or Equal | |
| 9 | SOS Group | HP01-07-05 | Spare - External Analog Back-Up Pressure Gauge (FSW/MSW) | 1 | Brand Name Or Equal | |
| 10 | SOS Group | HP01-09-12 | External Medical Lock Door Assembly | 1 | Brand Name Or Equal | |
| 11 | SOS Group | HP01-27-00 | Medlock Pocket Assembly | 1 | Brand Name Or Equal | |
| 12 | SOS Group | N/A | Spare - Over Pressure Relief Valve Set Required for No Downtime Maintenance Pack | 1 | Brand Name Or Equal | |
| 13 | N/A | N/A | IM2975 Case | 1 | Brand Name Or Equal | |
| 14 | N/A | N/A | Shipping to Hurlburt Field, FL (To include any additional cases or shipping containers) | 1 | N/A |